The DOI matches its Crossref record.
Transport and reaction in microscale segmented gas–liquid flow
Abstract
We use micro particle image velocimetry (microPIV) and fluorescence microscopy techniques to characterize microscale segmented gas-liquid flow at low superficial velocities relevant for chemical reactions with residence times of up to several minutes. Different gas-liquid microfluidic channel networks of rectangular cross section are fabricated in poly(dimethylsiloxane) (PDMS) using soft lithography techniques. The recirculation motion in the liquid segments associated with gas-liquid flows as well as the symmetry characteristics of the recirculations are quantified for straight and meandering channel networks. Even minor surface roughness effects and the compressibility of the gas phase induce loss of symmetry and enhance mixing across the centerline in straight channels. Mixing is further accelerated in meandering channels by the periodic switching of recirculation patterns across the channel center. We demonstrate a new, piezoelectrically activated flow injection technique for determining residence time distributions (RTDs) of fluid elements in multiphase microfluidic systems. The results confirm a narrowed liquid phase RTD in segmented flows in comparison to their single-phase counterparts. The enhanced mixing and narrow RTD characteristics of segmented gas-liquid flows are applied to liquid mixing and in sol-gel synthesis of colloidal nanoparticles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Formation of droplets and bubbles in a microfluidic T-junction—scaling and mechanism of break-up
Garstecki, P., Fuerstman, M. J., Stone, H. A., & Whitesides, G. M. (2006) · Lab on a Chip · doi:10.1039/b510841a · Cited by 2,339
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049
Multiphase microfluidics: from flow characteristics to chemical and materials synthesis
Günther, A., & Jensen, K. F. (2006) · Lab Chip · doi:10.1039/b609851g · Cited by 983
Self-citationSynthesis of micro and nanostructures in microfluidic systems
Marre, S., & Jensen, K. F. (2010) · Chemical Society Reviews · doi:10.1039/b821324k · Cited by 734
Self-citation
Metadata
- Authors
- Günther, A., Khan, S. A., Thalmann, M., Trachsel, F., & Jensen, K. F.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2004
- Volume
- 4
- Issue
- 4
- Pages
- 278-286
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1894736934
- Cited by
- 534
- References
- 0
- FWCI
- 17.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transport and reaction in microscale segmented gas–liquid flow. https://app.cochat.ai/papers/10.1039/b403982c
- The paper
- Günther, A., Khan, S. A., Thalmann, M., Trachsel, F., & Jensen, K. F. (2004). Transport and reaction in microscale segmented gas–liquid flow. Lab Chip. https://doi.org/10.1039/b403982c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.