The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Effects of flow and diffusion on chemotaxis studies in a microfabricated gradient generator
Open accessAbstract
An understanding of chemotaxis at the level of cell-molecule interactions is important because of its relevance in cancer, immunology, and microbiology, just to name a few. This study quantifies the effects of flow on cell migration during chemotaxis in a microfluidic device. The chemotaxis gradient within the device was modeled and compared to experimental results. Chemotaxis experiments were performed using the chemokine CXCL8 under different flow rates with human HL60 promyelocytic leukemia cells expressing a transfected CXCR2 chemokine receptor. Cell trajectories were separated into x and y axis components. When the microchannel flow rates were increased, cell trajectories along the x axis were found to be significantly affected (p < 0.05). Total migration distances were not affected. These results should be considered when using similar microfluidic devices for chemotaxis studies so that flow bias can be minimized. It may be possible to use this effect to estimate the total tractile force exerted by a cell during chemotaxis, which would be particularly valuable for cells whose tractile forces are below the level of detection with standard techniques of traction-force microscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Nelson, R. D., Quie, P. G., & Simmons, R. L. (1975) · The Journal of Immunology · doi:10.4049/jimmunol.115.6.1650 · Cited by 1,170
Li Jeon, N., Baskaran, H., Dertinger, S. K. W., Whitesides, G. M., Van De Water, L., & Toner, M. (2002) · Nature Biotechnology · doi:10.1038/nbt712 · Cited by 917
Ability of polymorphonuclear leukocytes to orient in gradients of chemotactic factors.
Zigmond, S. H. (1977) · The Journal of cell biology · doi:10.1083/jcb.75.2.606 · Cited by 907
Chemokines: multiple levels of leukocyte migration control☆
Moser, B., Wolf, M., Walz, A., & Loetscher, P. (2004) · Trends in Immunology · doi:10.1016/j.it.2003.12.005 · Cited by 860
Generation of Gradients Having Complex Shapes Using Microfluidic Networks
Dertinger, S. K. W., Chiu, D. T., Jeon, N. L., & Whitesides, G. M. (2001) · Analytical Chemistry · doi:10.1021/ac001132d · Cited by 839
Ismagilov, R. F., Stroock, A. D., Kenis, P. J. A., Whitesides, G., & Stone, H. A. (2000) · Applied Physics Letters · doi:10.1063/1.126351 · Cited by 540
Adler, J. (1975) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.44.070175.002013 · Cited by 522
A new direct-viewing chemotaxis chamber
Zicha, D., Dunn, G. A., & Brown, A. F. (1991) · Journal of Cell Science · doi:10.1242/jcs.99.4.769 · Cited by 386
Berg, H. C. (1975) · Annual Review of Biophysics and Bioengineering · doi:10.1146/annurev.bb.04.060175.001003 · Cited by 301
Cited by
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Biomolecular gradients in cell culture systems
Keenan, T. M., & Folch, A. (2008) · Lab Chip · doi:10.1039/b711887b · Cited by 596
Analysis of single mammalian cells on-chip
Sims, C. E., & Allbritton, N. L. (2007) · Lab on a Chip · doi:10.1039/b615235j · Cited by 400
Metadata
- Authors
- Walker, G. M., Sai, J., Richmond, A., Stremler, M., Chung, C. Y., & Wikswo, J. P.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2005
- Volume
- 5
- Issue
- 6
- Pages
- 611
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2093124126
- Cited by
- 266
- References
- 18
- FWCI
- 16.38
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of flow and diffusion on chemotaxis studies in a microfabricated gradient generator. https://app.cochat.ai/papers/10.1039/b417245k
- The paper
- Walker, G. M., Sai, J., Richmond, A., Stremler, M., Chung, C. Y., & Wikswo, J. P. (2005). Effects of flow and diffusion on chemotaxis studies in a microfabricated gradient generator. Lab on a Chip. https://doi.org/10.1039/b417245k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.