The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Controlled formulation of monodisperse double emulsions in a multiple-phase microfluidic system
Abstract
This paper gives an overview of our recent work on the use of microfluidic devices to formulate double emulsions. Key issues in the controlled encapsulation of highly monodisperse drops include: (a) regular periodicity in the formation of micro droplets due to the interplay between viscous shearing and interfacial tension in low Reynolds number streams; (b) serially connected hydrophobic and hydrophilic microchannels to form aqueous and organic drops consecutively. Water-in-oil-in-water emulsions and oil-in-water-in-oil emulsions can both be produced by reversing the order of hydrophobic and hydrophilic junctions. Alternating formation of aqueous droplets at a cross junction has enabled the production of organic droplets that encase two aqueous droplets of differing compositions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Formation of dispersions using “flow focusing” in microchannels
Anna, S. L., Bontoux, N., & Stone, H. A. (2003) · Applied Physics Letters · doi:10.1063/1.1537519 · Cited by 2,302
Dynamic Pattern Formation in a Vesicle-Generating Microfluidic Device
Thorsen, T., Roberts, R. W., Arnold, F. H., & Quake, S. R. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.4163 · Cited by 2,051
Micro/Nano encapsulation via electrified coaxial liquid jets
Loscertales, I. G., Barrero, A., Guerrero, I., Cortijo, R., Marquez, M., & Gañán-Calvo, A. M. (2002) · Science · doi:10.1126/science.1067595 · Cited by 1,017
Man-made cell-like compartments for molecular evolution
Tawfik, D. S., & Griffiths, A. D. (1998) · Nature Biotechnology · doi:10.1038/nbt0798-652 · Cited by 956
Tice, J. D., Song, H., Lyon, A. D., & Ismagilov, R. F. (2003) · Langmuir · doi:10.1021/la030090w · Cited by 722
Okushima, S., Nisisako, T., Torii, T., & Higuchi, T. (2004) · Langmuir · doi:10.1021/la0480336 · Cited by 656
Self-citationDroplet formation in a microchannel network
Nisisako, T., Torii, T., & Higuchi, T. (2002) · Lab Chip · doi:10.1039/b108740c · Cited by 607
Self-citationTan, Y.-C., Fisher, J. S., Lee, A. I., Cristini, V., & Lee, A. P. (2004) · Lab on a Chip · doi:10.1039/b403280m · Cited by 509
OGAWA, Y., YAMAMOTO, M., OKADA, H., YASHIKI, T., & SHIMAMOTO, T. (1988) · Chemical and Pharmaceutical Bulletin · doi:10.1248/cpb.36.1095 · Cited by 505
Particle control of emulsion by membrane emulsification and its applications
Nakashima, T., Shimizu, M., & Kukizaki, M. (2000) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(00)00099-5 · Cited by 406
Ordered and Disordered Patterns in Two-Phase Flows in Microchannels
Dreyfus, R., Tabeling, P., & Willaime, H. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.144505 · Cited by 404
Zheng, B., Tice, J. D., Roach, L. S., & Ismagilov, R. F. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200453974 · Cited by 398
Double emulsions — scope, limitations and new achievements
Garti, N. (1997) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/s0927-7757(96)03809-5 · Cited by 373
Suspension array technology: evolution of the flat-array paradigm
Nolan, J. P., & Sklar, L. A. (2002) · Trends in Biotechnology · doi:10.1016/s0167-7799(01)01844-3 · Cited by 349
Novel microreactors for functional polymer beads
Nisisako, T., Torii, T., & Higuchi, T. (2004) · Chemical Engineering Journal · doi:10.1016/j.cej.2003.11.019 · Cited by 346
Self-citationZheng, B., Tice, J. D., & Ismagilov, R. F. (2004) · Analytical Chemistry · doi:10.1021/ac0495743 · Cited by 321
Herbert, W. J. (1965) · The Lancet · doi:10.1016/s0140-6736(65)90816-0 · Cited by 260
Martin, K., Henkel, T., Baier, V., Grodrian, A., Schön, T., Roth, M., Michael Köhler, J., & Metze, J. (2003) · Lab Chip · doi:10.1039/b301258c · Cited by 183
Improvement of the encapsulation efficiency of oligonucleotide-containing biodegradable microspheres
Freytag, T., Dashevsky, A., Tillman, L., Hardee, G. E., & Bodmeier, R. A. (2000) · Journal of Controlled Release · doi:10.1016/s0168-3659(00)00299-6 · Cited by 135
Multiple emulsion technology for the design of microspheres containing peptides and oligopeptides
Couvreur, P., Blanco‐Prieto, M. J., Puisieux, F., Roques, B. P., & Fattal, E. (1997) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(97)00052-5 · Cited by 119
Cited by
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Micro Total Analysis Systems. Latest Advancements and Trends
Dittrich, P. S., Tachikawa, K., & Manz, A. (2006) · Analytical Chemistry · doi:10.1021/ac0605602 · Cited by 950
Microfluidic methods for generating continuous droplet streams
Christopher, G. F., & Anna, S. L. (2007) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/40/19/r01 · Cited by 860
Hollow Micro/Nanomaterials with Multilevel Interior Structures
Zhao, Y., & Jiang, L. (2009) · Advanced Materials · doi:10.1002/adma.200803645 · Cited by 654
The Synthesis and Assembly of Polymeric Microparticles Using Microfluidics
Dendukuri, D., & Doyle, P. S. (2009) · Advanced Materials · doi:10.1002/adma.200803386 · Cited by 654
Metadata
- Authors
- Nisisako, T., Okushima, S., & Torii, T.
- Venue
- Soft Matter
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2005
- Volume
- 1
- Issue
- 1
- Pages
- 23
- ISSN
- 1744-683X (ISSN-L)
- 1744-6848
- OpenAlex
- W2145936207
- Cited by
- 335
- References
- 20
- FWCI
- 8.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.