The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Isolation of plasma from whole blood using planar microfilters for lab-on-a-chip applications
Abstract
Researchers are actively developing devices for the microanalysis of complex fluids, such as blood. These devices have the potential to revolutionize biological analysis in a manner parallel to the computer chip by providing very high throughput screening of complex samples and massively parallel bioanalytical capabilities. A necessary step performed in clinical chemistry is the isolation of plasma from whole blood, and effective sample preparation techniques are needed for the development of miniaturized clinical diagnostic devices. This study demonstrates the use of passive, operating entirely on capillary action, transverse-flow microfilter devices for the microfluidic isolation of plasma from whole blood. Using these planar microfilters, blood can be controllably fractionated with minimal cell lysis. A characterization of the device performance reveals that plasma filter flux is dependent upon the wall shear rate of blood in the filtration channel, and this result is consistent with macroscale blood filtration using microporous membranes. Also, an innovative microfluidic layout is demonstrated that extends device operation time via capillary action from seconds to minutes. Efficiency of these microfilters is approximately three times higher than the separation efficiencies predicted for microporous membranes under similar conditions. As such, the application of the microscale blood filtration designs used in this study may have broad implications in the design of lab-on-a-chip devices, as well as the field of separation science.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Dynamics of Capillary Flow
Washburn, E. W. (1921) · Physical Review · doi:10.1103/physrev.17.273 · Cited by 7,141
THE VISCOSITY OF THE BLOOD IN NARROW CAPILLARY TUBES
Fåhræus, R., & Lindqvist, T. (1931) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1931.96.3.562 · Cited by 1,268
Integrated microfluidic devices
Erickson, D., & Li, D. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.09.019 · Cited by 726
Lab-on-a-Chip: A Revolution in Biological and Medical Sciences.
Figeys, D., & Pinto, D. (2000) · Analytical Chemistry · doi:10.1021/ac002800y · Cited by 562
Microfabricated Centrifugal Microfluidic Systems: Characterization and Multiple Enzymatic Assays
Duffy, D. C., Gillis, H. L., Lin, J., Sheppard, N. F., & Kellogg, G. J. (1999) · Analytical Chemistry · doi:10.1021/ac990682c · Cited by 478
Trends in miniaturized total analysis systems for point-of-care testing in clinical chemistry
Tüdős, A. J., Besselink, G. A. J., & Schasfoort, R. B. M. (2001) · Lab Chip · doi:10.1039/b106958f · Cited by 426
HOME MONITORING OF BLOOD-GLUCOSE
Sönksen, P. H., Judd, S. L., & Lowy, C. (1978) · The Lancet · doi:10.1016/s0140-6736(78)90854-1 · Cited by 341
Integrated Cell Isolation and Polymerase Chain Reaction Analysis Using Silicon Microfilter Chambers
Wilding, P., Kricka, L. J., Cheng, J., Hvichia, G., Shoffner, M. A., & Fortina, P. (1998) · Analytical Biochemistry · doi:10.1006/abio.1997.2530 · Cited by 276
SELF-MONITORING OF BLOOD-GLUCOSE
Walford, S., Gale, E. A. M., Allison, S. P., & Tattersall, R. B. (1978) · The Lancet · doi:10.1016/s0140-6736(78)90855-3 · Cited by 268
Microfluidic technologies in clinical diagnostics
Schulte, T. H., Bardell, R. L., & Weigl, B. H. (2002) · Clinica Chimica Acta · doi:10.1016/s0009-8981(02)00093-1 · Cited by 245
Cited by
Label-free cell separation and sorting in microfluidic systems
Gossett, D. R., Weaver, W. M., Mach, A. J., Hur, S. C., Tse, H. T. K., Lee, W., Amini, H., & Di Carlo, D. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3721-9 · Cited by 930
A novel 3D mammalian cell perfusion-culture system in microfluidic channels
Toh, Y.-C., Zhang, C., Zhang, J., Khong, Y. M., Chang, S., Samper, V. D., van Noort, D., Hutmacher, D. W., & Yu, H. (2007) · Lab on a Chip · doi:10.1039/b614872g · Cited by 414
Hydrodynamic mechanisms of cell and particle trapping in microfluidics
Karimi, A., Yazdi, S., & Ardekani, A. M. (2013) · Biomicrofluidics · doi:10.1063/1.4799787 · Cited by 384
Recent progress of particle migration in viscoelastic fluids
Yuan, D., Zhao, Q., Yan, S., Tang, S.-Y., Alici, G., Zhang, J., & Li, W. (2018) · Lab on a Chip · doi:10.1039/c7lc01076a · Cited by 258
Metadata
- Authors
- Crowley, T. A., & Pizziconi, V.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2005
- Volume
- 5
- Issue
- 9
- Pages
- 922
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2009223004
- Cited by
- 280
- References
- 18
- FWCI
- 6.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Isolation of plasma from whole blood using planar microfilters for lab-on-a-chip applications. https://app.cochat.ai/papers/10.1039/b502930a
- The paper
- Crowley, T. A., & Pizziconi, V. (2005). Isolation of plasma from whole blood using planar microfilters for lab-on-a-chip applications. Lab on a Chip. https://doi.org/10.1039/b502930a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.