Ratiometric fiber optic sensors for the detection of inter- and intra-cellular dissolved oxygen
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A sensor platform was developed for the detection of inter- and intra-cellular dissolved oxygen, using a fiber optic probe. The design and fabrication of the oxygen fiber optic sensor are based on the excellent luminescence quenching properties of the near-infrared oxygen sensitive platinum(II) octaethylporphine ketone (PtOEPK) dye. Together with a reference dye, octaethyl porphyrin (OEP) or bodipy maleimide 577/618, the dye was entrapped, in an easily renewable liquid polymer matrix, made of polyvinyl chloride, including the plastisizing agent bis(2-ethylhexyl) sebacate (DOS). Multi-mode fibers were pulled down to submicron dimensions and a dip coating procedure was used to apply the sensing membrane film to the tip. This sensor was fully characterized and exhibits excellent reversibility, minimal photobleaching and leaching, and fast response times. The resulting oxygen sensor is one of the most sensitive optical oxygen sensors to date, with good linearity in the Stern–Volmer plot calibrations. This sensor is ultimately intended for biological inter- and intra-cellular measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Abnormal patterns of insulin secretion in non-insulin-dependent diabetes mellitus.
Polonsky, K. S., Given, B. D., Hirsch, L. J., Tillil, H., Shapiro, E. T., Beebe, C., Frank, B. H., Galloway, J. A., & Van Cauter, E. (1988) · New England Journal of Medicine · doi:10.1056/nejm198805123181903 · Cited by 567
Impaired Pulsatile Secretion of Insulin in Relatives of Patients with Non-Insulin-Dependent Diabetes
O'Rahilly, S., Turner, R. C., & Matthews, D. R. (1988) · New England Journal of Medicine · doi:10.1056/nejm198805123181902 · Cited by 540
Cited by
Optical methods for sensing and imaging oxygen: materials, spectroscopies and applications
Wang, X.-D., & Wolfbeis, O. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00039k · Cited by 1,114
McDonagh, C., Burke, C. S., & MacCraith, B. D. (2008) · Chemical Reviews · doi:10.1021/cr068102g · Cited by 1,026
Indicators for optical oxygen sensors
Quaranta, M., Borisov, S. M., & Klimant, I. (2012) · Bioanalytical Reviews · doi:10.1007/s12566-012-0032-y · Cited by 452
Oxygen control with microfluidics
Brennan, M. D., Rexius-Hall, M. L., Elgass, L. J., & Eddington, D. T. (2014) · Lab Chip · doi:10.1039/c4lc00853g · Cited by 188
Organs-on-chip monitoring: sensors and other strategies
Kilic, T., Navaee, F., Stradolini, F., Renaud, P., & Carrara, S. (2018) · Microphysiological Systems · doi:10.21037/mps.2018.01.01 · Cited by 96
“This configuration enables the possibility to move the probe within the sample while measuring (136).”
BackgroundSensors in Disposable Bioreactors Status and Trends
Glindkamp, A., Riechers, D., Rehbock, C., Hitzmann, B., Scheper, T., & Reardon, K. F. (2009) · Advances in Biochemical Engineering/Biotechnology · doi:10.1007/10_2009_10 · Cited by 65
Metadata
- Authors
- Park, E. J., Reid, K. R., Tang, W., Kennedy, R. T., & Kopelman, R.
- Venue
- Journal of Materials Chemistry
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2005
- Volume
- 15
- Issue
- 27-28
- Pages
- 2913
- ISSN
- 0959-9428 (ISSN-L)
- 1364-5501
- OpenAlex
- W2005259284
- Cited by
- 92
- References
- 2
- FWCI
- 4.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.