Microfluidic arrays for logarithmically perfused embryonic stem cell culture
Abstract
We present a microfluidic device for culturing adherent cells over a logarithmic range of flow rates. The device sets flow rates through four separate cell-culture chambers using syringe-driven flow and a network of fluidic resistances. The design is easy to fabricate with no on-chip valves and is scalable both in the number of culture chambers as well as in the range of applied flow rates. Using particle velocimetry, we have characterized the flow-rate range. We have also demonstrated an extension of the design that combines the logarithmic flow-rate functionality with a logarithmic concentration gradient across the array. Using fluorescence measurements we have verified that a logarithmic concentration gradient was established in the extended device. Compared with static cell culture, both devices enable greater control over the soluble microenvironment by controlling the transport of molecules to and away from the cells. This approach is particularly relevant for cell types such as embryonic stem cells (ESCs) which are especially sensitive to the microenvironment. We have demonstrated for the first time culture of murine ESCs (mESCs) in continuous, logarithmically scaled perfusion for 4 days, with flow rates varying >300x across the array. Cells grown in the slowest flow rate did not proliferate, while colonies grown in higher flow rates exhibited healthy round morphology. We have also demonstrated logarithmically scaled continuous perfusion culture of 3T3 fibroblasts for 3 days, with proliferation at all flow rates except the slowest rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Analysis of transport phenomena
Deen, W. M. (1998) · Cited by 1,237
An extracellular matrix microarray for probing cellular differentiation
Flaim, C. J., Chien, S., & Bhatia, S. N. (2005) · Nature Methods · doi:10.1038/nmeth736 · Cited by 803
Differentiation of human embryonic stem cells on three-dimensional polymer scaffolds
Levenberg, S., Huang, N. F., Lavik, E., Rogers, A. B., Itskovitz-Eldor, J., & Langer, R. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1735463100 · Cited by 692
Continuous perfusion microfluidic cell culture array for high‐throughput cell‐based assays
Hung, P. J., Lee, P. J., Sabounchi, P., Lin, R., & Lee, L. P. (2005) · Biotechnology and Bioengineering · doi:10.1002/bit.20289 · Cited by 522
A microfabricated array bioreactor for perfused 3D liver culture
Powers, M. J., Domansky, K., Kaazempur‐Mofrad, M. R., Kalezi, A., Capitano, A., Upadhyaya, A., Kurzawski, P., Wack, K. E., Stolz, D. B., Kamm, R., et al. (2002) · Biotechnology and Bioengineering · doi:10.1002/bit.10143 · Cited by 462
Microfluidic Shear Devices for Quantitative Analysis of Cell Adhesion
Lu, H., Koo, L. Y., Wang, W. M., Lauffenburger, D. A., Griffith, L. G., & Jensen, K. F. (2004) · Analytical Chemistry · doi:10.1021/ac049837t · Cited by 405
Computerized microfluidic cell culture using elastomeric channels and Braille displays
Gu, W., Zhu, X., Futai, N., Cho, B. S., & Takayama, S. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0404353101 · Cited by 403
Differentiation-on-a-chip: A microfluidic platform for long-term cell culture studies
Tourovskaia, A., Figueroa-Masot, X., & Folch, A. (2005) · Lab on a Chip · doi:10.1039/b405719h · Cited by 363
Tilles, A. W., Baskaran, H., Roy, P., Yarmush, M. L., & Toner, M. (2001) · Biotechnology and Bioengineering · doi:10.1002/bit.1071 · Cited by 330
Computer-Controlled Microcirculatory Support System for Endothelial Cell Culture and Shearing
Song, J. W., Gu, W., Futai, N., Warner, K. A., Nor, J. E., & Takayama, S. (2005) · Analytical Chemistry · doi:10.1021/ac050131o · Cited by 249
In Vitro Zonation and Toxicity in a Hepatocyte Bioreactor
Allen, J. W. (2005) · Toxicological Sciences · doi:10.1093/toxsci/kfi052 · Cited by 233
Fok, E. Y. L., & Zandstra, P. W. (2005) · STEM CELLS · doi:10.1634/stemcells.2005-0112 · Cited by 232
Dielectrophoretic Traps for Single-Particle Patterning
Rosenthal, A., & Voldman, J. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.049684 · Cited by 210
Self-citationMicrofabricated platform for studying stem cell fates
Chin, V. I., Taupin, P., Sanga, S., Scheel, J., Gage, F. H., & Bhatia, S. N. (2004) · Biotechnology and Bioengineering · doi:10.1002/bit.20254 · Cited by 202
Gaver, D. P., & Kute, S. M. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77562-9 · Cited by 171
Dynamic Gene Expression Profiling Using a Microfabricated Living Cell Array
Thompson, D. M., King, K. R., Wieder, K. J., Toner, M., Yarmush, M. L., & Jayaraman, A. (2004) · Analytical Chemistry · doi:10.1021/ac0354241 · Cited by 168
Perfusion Bioreactor for Small Diameter Tissue-Engineered Arteries
Williams, C., & Wick, T. M. (2004) · Tissue Engineering · doi:10.1089/1076327041348536 · Cited by 152
Perfusion and chemical monitoring of living cells on a microfluidic chip
Shackman, J. G., Dahlgren, G. M., Peters, J. L., & Kennedy, R. T. (2004) · Lab on a Chip · doi:10.1039/b404974h · Cited by 144
Microfluidic Gradient-Generating Device for Pharmacological Profiling
Pihl, J., Sinclair, J., Sahlin, E., Karlsson, M., Petterson, F., Olofsson, J., & Orwar, O. (2005) · Analytical Chemistry · doi:10.1021/ac050218+ · Cited by 135
Prudhomme, W., Daley, G. Q., Zandstra, P. W., & Lauffenburger, D. A. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0308768101 · Cited by 109
NanoLiterBioReactor: Long-Term Mammalian Cell Culture at Nanofabricated Scale
Prokop, A., Prokop, Z., Schaffer, D. K., Kozlov, E., Wikswo, J. P., Cliffel, D. E., & Baudenbacher, F. J. (2004) · Biomedical Microdevices · doi:10.1023/b:bmmd.0000048564.37800.d6 · Cited by 97
Analysis of Oxygen Transport to Hepatocytes in a Flat-Plate Microchannel Bioreactor
Roy, P. S., Baskaran, H., Tilles, A. W., Yarmush, M. L., & Toner, M. (2001) · Annals of Biomedical Engineering · doi:10.1114/1.1415524 · Cited by 80
Perfusion culture of fetal human hepatocytes in microfluidic environments
Leclerc, É., Sakai, Y., & Fujii, T. (2004) · Biochemical Engineering Journal · doi:10.1016/j.bej.2003.09.010 · Cited by 73
Viswanathan, S., Benatar, T., Mileikovsky, M., Lauffenburger, D. A., Nagy, A., & Zandstra, P. W. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10799 · Cited by 51
Culturing and differentiation of murine embryonic stem cells in a three-dimensional fibrous matrix
Li, Y., Kniss, D. A., Lasky, L. C., & Yang, S. (2003) · Cytotechnology · doi:10.1023/a:1024283521966 · Cited by 46
Human Embryonic Stem Cell Culture
Gonzalez, R., Loring, J. F., esselschmidt, R. L., & Schartz, P. H. (2007) · Elsevier eBooks · doi:10.1016/b978-012370465-8/50006-5 · Cited by 8
Cited by
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
Dynamic single cell culture array
Carlo, D. D., Wu, L. Y., & Lee, L. P. (2006) · Lab on a Chip · doi:10.1039/b605937f · Cited by 707
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Microfluidic Devices for Bioapplications
Yeo, L. Y., Chang, H., Chan, P. P. Y., & Friend, J. R. (2011) · Small · doi:10.1002/smll.201000946 · Cited by 622
Engineered Microenvironments for Controlled Stem Cell Differentiation
Burdick, J. A., & Vunjak-Novakovic, G. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0131 · Cited by 485
Metadata
- Authors
- Kim, L., Vahey, M. D., Lee, H.-Y., & Voldman, J.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2006
- Volume
- 6
- Issue
- 3
- Pages
- 394
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2138803549
- Cited by
- 262
- References
- 30
- FWCI
- 16.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.