The DOI matches its Crossref record.
Microfluidic system for measuring neutrophil migratory responses to fast switches of chemical gradients
Open accessAbstract
Experimental systems that provide temporal and spatial control of chemical gradients are required for probing into the complex mechanisms of eukaryotic cell chemotaxis. However, no current technique can simultaneously generate stable chemical gradients and allow fast gradient changes. We developed a microfluidic system with microstructured membranes for exposing neutrophils to fast and precise changes between stable, linear gradients of the known chemoattractant Interleukin-8 (IL-8). We observed that rapidly lowering the average concentration of IL-8 within a gradient, while preserving the direction of the gradient, resulted in temporary neutrophil depolarization. Fast reversal of the gradient direction while increasing or decreasing the average concentration also resulted in temporary depolarization. Neutrophils adapted and maintained their directional motility, only when the average gradient concentration was increased and the direction of the gradient preserved. Based on these observations we propose a two-component temporal sensing mechanism that uses variations of chemokine concentration averaged over the entire cell surface and localized at the leading edge, respectively, and directs neutrophil responses to changes in their chemical microenvironment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 29
- Zigmond, 1974, Nature, 249, 450, 10.1038/249450a0 · DOI · Paper page
- Iijima, 2002, Dev. Cell, 3, 469, 10.1016/S1534-5807(02)00292-7 · DOI · Paper page
- Xu, 2003, Cell, 114, 201, 10.1016/S0092-8674(03)00555-5 · DOI · Paper page
- Bourne, 2002, Nature, 419, 21, 10.1038/419021a · doi:10.1038/419021a
- Gerisch, 1981, J. Cell Sci., 52, 1, 10.1242/jcs.52.1.1 · DOI · Paper page
- Geiger, 2003, Cell Motil. Cytoskeleton, 56, 27, 10.1002/cm.10133 · DOI
- Albrecht, 1998, Proc. Natl. Acad. Sci. U. S. A., 95, 5039, 10.1073/pnas.95.9.5039 · doi:10.1073/pnas.95.9.5039
- Frow, 2004, Med. Res. Rev., 24, 267, 10.1002/med.10062 · DOI
- Wilkinson, 1998, J. Immunol. Methods, 216, 139, 10.1016/S0022-1759(98)00075-1 · DOI
- Boyden, 1962, J. Exp. Med., 115, 453, 10.1084/jem.115.3.453 · DOI · Paper page
- Zicha, 1991, J. Cell Sci., 99, 769, 10.1242/jcs.99.4.769 · DOI · Paper page
- Zigmond, 1977, J. Cell Biol., 75, 606, 10.1083/jcb.75.2.606 · DOI · Paper page
- Jeon, 2002, Nature Biotechnol., 20, 826, 10.1038/nbt712 · DOI · Paper page
- Tharp, 2005, J. Leukocyte Biol., 10.1189/jlb.0905516 · DOI
- Lin, 2004, Lab Chip, 4, 164, 10.1039/b313600k · DOI · Paper page
- Vicker, 1981, Exp. Cell Res., 136, 91, 10.1016/0014-4827(81)90040-9 · doi:10.1016/0014-4827(81)90040-9
- Miller, 2005, J. Neurosci., 25, 3369, 10.1523/JNEUROSCI.5133-04.2005 · DOI
- Tager, 1998, Am. J. Respir. Cell Mol. Biol., 19, 643, 10.1165/ajrcmb.19.4.3165 · DOI
- Studer, 2004, J. Appl. Phys., 95, 393, 10.1063/1.1629781 · doi:10.1063/1.1629781
- Unger, 2000, Science, 288, 113, 10.1126/science.288.5463.113 · DOI · Paper page
- Hsu, 2005, Appl. Phys. Lett., 86, 023508, 10.1063/1.1850593 · doi:10.1063/1.1850593
- Zadeh, 2003, Eur. J. Cell Biol., 82, 93, 10.1078/0171-9335-00295 · doi:10.1078/0171-9335-00295
- Zigmond, 1981, J. Cell Biol., 89, 585, 10.1083/jcb.89.3.585 · DOI · Paper page
- Zigmond, 1979, J. Cell Biol., 82, 517, 10.1083/jcb.82.2.517 · DOI · Paper page
- Ebrahimzadeh, 1999, J. Leukocyte Biol., 66, 90, 10.1002/jlb.66.1.90 · doi:10.1002/jlb.66.1.90
- Keller, 1984, Exp. Cell Res., 153, 173, 10.1016/0014-4827(84)90459-2 · DOI
- Walker, 2005, Lab Chip, 5, 611, 10.1039/b417245k · DOI · Paper page
- Cinamon, 2001, Nat. Immunol., 2, 515, 10.1038/88710 · DOI · Paper page
- Mempel, 2004, Curr. Opin. Immunol., 16, 406, 10.1016/j.coi.2004.05.018 · DOI · Paper page
Cited by
Polymer microfabrication technologies for microfluidic systems
Becker, H., & Gärtner, C. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1692-2 · Cited by 860
Microfluidic Large-Scale Integration: The Evolution of Design Rules for Biological Automation
Melin, J., & Quake, S. R. (2007) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.36.040306.132646 · Cited by 738
Microfluidic Devices for Bioapplications
Yeo, L. Y., Chang, H., Chan, P. P. Y., & Friend, J. R. (2011) · Small · doi:10.1002/smll.201000946 · Cited by 622
Microfluidic culture platform for neuroscience research
Park, J. W., Vahidi, B., Taylor, A. M., Rhee, S. W., & Jeon, N. L. (2006) · Nature Protocols · doi:10.1038/nprot.2006.316 · Cited by 464
Applications of microfluidics in chemical biology
Weibel, D. B., & Whitesides, G. M. (2006) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2006.10.016 · Cited by 443
Metadata
- Authors
- Irimia, D., Liu, S.-Y., Tharp, W. G., Samadani, A., Toner, M., & Poznansky, M. C.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2006
- Volume
- 6
- Issue
- 2
- Pages
- 191-198
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2000147099
- Cited by
- 196
- References
- 0
- FWCI
- 9.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microfluidic system for measuring neutrophil migratory responses to fast switches of chemical gradients. https://app.cochat.ai/papers/10.1039/b511877h
- The paper
- Irimia, D., Liu, S.-Y., Tharp, W. G., Samadani, A., Toner, M., & Poznansky, M. C. (2006). Microfluidic system for measuring neutrophil migratory responses to fast switches of chemical gradients. Lab Chip. https://doi.org/10.1039/b511877h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.