The DOI matches its Crossref record.
A three-channel microfluidic device for generating static linear gradients and its application to the quantitative analysis of bacterial chemotaxis
Abstract
We have developed a prototype three-channel microfluidic chip that is capable of generating a linear concentration gradient within a microfluidic channel and is useful in the study of bacterial chemotaxis. The linear chemical gradient is established by diffusing a chemical through a porous membrane located in the side wall of the channel and can be established without through-flow in the channel where cells reside. As a result, movement of the cells in the center channel is caused solely by the cells chemotactic response and not by variations in fluid flow. The advantages of this microfluidic chemical linear gradient generator are (i) its ability to produce a static chemical gradient, (ii) its rapid implementation, and (iii) its potential for highly parallel sample processing. Using this device, wildtype Escherichia coli strain RP437 was observed to move towards an attractant (e.g., l-asparate) and away from a repellent (e.g., glycerol) while derivatives of RP437 that were incapable of motility or chemotaxis showed no bias of the bacteria's distribution. Additionally, the degree of chemotaxis could be easily quantified using this assay in conjunction with fluorescence imaging techniques, allowing for estimation of the chemotactic partition coefficient (CPC) and the chemotactic migration coefficient (CMC). Finally, using this approach we demonstrate that E. coli deficient in autoinducer-2-mediated quorum sensing respond to the chemoattractant l-aspartate in a manner that is indistinguishable from wildtype cells suggesting that chemotaxis is insulated from this mode of cell-cell communication.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microfluidic scaffolds for tissue engineering
Choi, N. W., Cabodi, M., Held, B., Gleghorn, J. P., Bonassar, L. J., & Stroock, A. D. (2007) · Nature Materials · doi:10.1038/nmat2022 · Cited by 622
Biomolecular gradients in cell culture systems
Keenan, T. M., & Folch, A. (2008) · Lab Chip · doi:10.1039/b711887b · Cited by 596
Review of cell and particle trapping in microfluidic systems
Nilsson, J., Evander, M., Hammarström, B., & Laurell, T. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.07.017 · Cited by 534
Biological applications of microfluidic gradient devices
Kim, S., Kim, H. J., & Jeon, N. L. (2010) · Integrative Biology · doi:10.1039/c0ib00055h · Cited by 366
Self-citationA hydrogel-based microfluidic device for the studies of directed cell migration
Cheng, S.-Y., Heilman, S., Wasserman, M., Archer, S., Shuler, M. L., & Wu, M. (2007) · Lab on a Chip · doi:10.1039/b618463d · Cited by 359
Self-citation
Metadata
- Authors
- Diao, J., Young, L., Kim, S., Fogarty, E. A., Heilman, S. M., Zhou, P., Shuler, M. L., Wu, M., & DeLisa, M. P.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2006
- Volume
- 6
- Issue
- 3
- Pages
- 381-388
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2151722350
- Cited by
- 239
- References
- 0
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A three-channel microfluidic device for generating static linear gradients and its application to the quantitative analysis of bacterial chemotaxis. https://app.cochat.ai/papers/10.1039/b511958h
- The paper
- Diao, J., Young, L., Kim, S., Fogarty, E. A., Heilman, S. M., Zhou, P., Shuler, M. L., Wu, M., & DeLisa, M. P. (2006). A three-channel microfluidic device for generating static linear gradients and its application to the quantitative analysis of bacterial chemotaxis. Lab Chip. https://doi.org/10.1039/b511958h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.