The DOI matches its Crossref record.
A hydrogel-based microfluidic device for the studies of directed cell migration
Abstract
We have developed a hydrogel-based microfluidic device that is capable of generating a steady and long term linear chemical concentration gradient with no through flow in a microfluidic channel. Using this device, we successfully monitored the chemotactic responses of wildtype Escherichia coli (suspension cells) to alpha-methyl-DL-aspartate (attractant) and differentiated HL-60 cells (a human neutrophil-like cell line that is adherent) to formyl-Met-Leu-Phe (f-MLP, attractant). This device advances the current state of the art in microchemotaxis devices in that (1) it demonstrates the validity of using hydrogels as the building material for a microchemotaxis device; (2) it demonstrates the potential of the hydrogel based microfluidic device in biological experiments since most of the proteins and nutrients essential for cell survival are readily diffusible in hydrogel; (3) it is capable of applying chemical stimuli independently of mechanical stimuli; (4) it is straightforward to make, and requires very basic tools that are commonly available in biological labs. This device will also be useful in controlling the chemical and mechanical environment during the formation of tissue engineered constructs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomolecular gradients in cell culture systems
Keenan, T. M., & Folch, A. (2008) · Lab Chip · doi:10.1039/b711887b · Cited by 596
Multifunctional Bacteria-Driven Microswimmers for Targeted Active Drug Delivery
Park, B.-W., Zhuang, J., Yasa, O., & Sitti, M. (2017) · ACS Nano · doi:10.1021/acsnano.7b03207 · Cited by 384
Biological applications of microfluidic gradient devices
Kim, S., Kim, H. J., & Jeon, N. L. (2010) · Integrative Biology · doi:10.1039/c0ib00055h · Cited by 366
Concentration gradient generation methods based on microfluidic systems
Wang, X., Liu, Z., & Pang, Y. (2017) · RSC Advances · doi:10.1039/c7ra04494a · Cited by 219
Buchanan, C. F., Voigt, E. E., Szot, C. S., Freeman, J. W., Vlachos, P. P., & Rylander, M. N. (2014) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2012.0731 · Cited by 143
Metadata
- Authors
- Cheng, S.-Y., Heilman, S., Wasserman, M., Archer, S., Shuler, M. L., & Wu, M.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2007
- Volume
- 7
- Issue
- 6
- Pages
- 763
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2013717626
- Cited by
- 359
- References
- 0
- FWCI
- 13.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A hydrogel-based microfluidic device for the studies of directed cell migration. https://app.cochat.ai/papers/10.1039/b618463d
- The paper
- Cheng, S.-Y., Heilman, S., Wasserman, M., Archer, S., Shuler, M. L., & Wu, M. (2007). A hydrogel-based microfluidic device for the studies of directed cell migration. Lab on a Chip. https://doi.org/10.1039/b618463d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.