The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
T cell chemotaxis in a simple microfluidic device
Abstract
This paper describes the use of a simple microfluidic device for studying T cell chemotaxis. The microfluidic device is fabricated in poly(dimethylsiloxane) (PDMS) using soft-lithography and consists of a "Y" type fluidic channel. Solutions are infused into the device by syringe pumps and generate a concentration gradient in the channel by diffusion. We show that the experimentally measured gradient profiles agree nicely with theoretical predictions and the gradient is stable in the observation region for cell migration. Using this device, we demonstrate robust chemotaxis of human T cells in response to single and competing gradients of chemokine CCL19 and CXCL12. Because of the simplicity of the device, it can flexibly control gradient generation in space and time, and would allow generation of multiple gradient conditions in a single chip for highly parallel chemotaxis experimentation. Visualization of T cell chemotaxis has previously been limited to studies in 3D matrices or under agarose assays, which do not allow precise control or variation in conditions. Acknowledging the importance of lymphocyte homing in the adaptive immune response, the ability to study T cell chemotaxis in microfluidic devices offers a new approach for investigating lymphocyte migration and chemotaxis in vitro.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chemokines, sphingosine-1-phosphate, and cell migration in secondary lymphoid organs
Cyster, J. G. (2005) · Annual Review of Immunology · doi:10.1146/annurev.immunol.23.021704.115628 · Cited by 856
CCR7 Expression and Memory T Cell Diversity in Humans
Campbell, J. J., Murphy, K. E., Kunkel, E. J., Brightling, C. E., Soler, D., Shen, Z., Boisvert, J., Greenberg, H. B., Vierra, M. A., Goodman, S. B., et al. (2001) · The Journal of Immunology · doi:10.4049/jimmunol.166.2.877 · Cited by 335
Self-citation
Cited by
Microfluidic cell culture systems for drug research
Wu, M.-H., Huang, S.-B., & Lee, G.-B. (2010) · Lab on a Chip · doi:10.1039/b921695b · Cited by 432
Micro Total Analysis Systems: Latest Achievements
West, J., Becker, M., Tombrink, S., & Manz, A. (2008) · Analytical Chemistry · doi:10.1021/ac800680j · Cited by 423
Biological applications of microfluidic gradient devices
Kim, S., Kim, H. J., & Jeon, N. L. (2010) · Integrative Biology · doi:10.1039/c0ib00055h · Cited by 366
A hydrogel-based microfluidic device for the studies of directed cell migration
Cheng, S.-Y., Heilman, S., Wasserman, M., Archer, S., Shuler, M. L., & Wu, M. (2007) · Lab on a Chip · doi:10.1039/b618463d · Cited by 359
Microfluidics: A New Tool for Modeling Cancer–Immune Interactions
Boussommier-Calleja, A., Li, R., Chen, M. B., Wong, S. C., & Kamm, R. D. (2016) · Trends in Cancer · doi:10.1016/j.trecan.2015.12.003 · Cited by 224
“have been used to analyze T cell[67] or neutrophil migratory behavior under chemical gradients[68]; the migration of dendritic cells, macrophages and T cells through microchannels towards bacteria[44]; the rolling of neutrophils[69] and their extravasation through endothelium[70]; or the adhesion of T cells[71] or mon…”
Method
Metadata
- Authors
- Lin, F., & Butcher, E. C.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2006
- Volume
- 6
- Issue
- 11
- Pages
- 1462-1469
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1966571267
- Cited by
- 211
- References
- 2
- FWCI
- 6.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.