The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Capillary pumps for autonomous capillary systems
Abstract
Autonomous capillary systems (CSs), where liquids are displaced by means of capillarity, are efficient, fast and convenient platforms for many bioanalytical applications. The proper functioning of these microfluidic devices requires displacing accurate volumes of liquids with precise flow rates. In this work, we show how to design capillary pumps for controlling the flow properties of CSs. The capillary pumps comprise microstructures of various shapes with dimensions from 15-250 microm, which are positioned in the capillary pumps to encode a desired capillary pressure. The capillary pumps are designed to have a small flow resistance and are preceded by a constricted microchannel, which acts as a flow resistance. Therefore, both the capillary pump and the flow resistance define the flow rate in the CS, and flow rates from 0.2-3.7 nL s(-1) were achieved. The placement and the shape of the microstructures in the capillary pumps are used to tailor the filling front of liquids in the capillary pumps to obtain a reliable filling behaviour and to minimize the risk of entrapping air. The filling front can, for example, be oriented vertically or tilted to the main axis of the capillary pump. We also show how capillary pumps having different hydrodynamic properties can be connected to program a sequence of slow and fast flow rates in a CS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Capillarity and Wetting Phenomena
de Gennes, P.-G., Brochard-Wyart, F., & Quéré, D. (2004) · Springer eBooks · doi:10.1007/978-0-387-21656-0 · Cited by 3,121
Functional hydrogel structures for autonomous flow control inside microfluidic channels
Beebe, D. J., Moore, J. S., Bauer, J. M., Yu, Q., Liu, R. H., Devadoss, C., & Jo, B.-H. (2000) · Nature · doi:10.1038/35007047 · Cited by 1,971
The dynamics of the spreading of liquids on a solid surface. Part 1. Viscous flow
Cox, R. G. (1986) · Journal of Fluid Mechanics · doi:10.1017/s0022112086000332 · Cited by 1,435
Polymer microstructures formed by moulding in capillaries
Kim, E., Xia, Y., & Whitesides, G. M. (1995) · Nature · doi:10.1038/376581a0 · Cited by 878
Biotechnology at low Reynolds numbers
Brody, J. P., Yager, P., Goldstein, R. E., & Austin, R. H. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79538-3 · Cited by 523
Disposable Smart Lab on a Chip for Point-of-Care Clinical Diagnostics
Ahn, C. H., Choi, J.-W., Beaucage, G., Nevin, J., Lee, J.-B., Puntambekar, A., & Lee, R. J. Y. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820548 · Cited by 504
Autonomous Microfluidic Capillary System
Juncker, D., Schmid, H., Drechsler, U., Wolf, H., Wolf, M., Michel, B., de Rooij, N., & Delamarche, E. (2002) · Analytical Chemistry · doi:10.1021/ac0261449 · Cited by 426
Self-citationMicrofluidic Networks for Chemical Patterning of Substrates: Design and Application to Bioassays
Delamarche, E., Bernard, A., Schmid, H., Bietsch, A., Michel, B., & Biebuyck, H. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973071f · Cited by 412
Self-citationMicropumps—past, progress and future prospects
WOIAS, P. (2005) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(04)00108-x · Cited by 411
Micropumps—past, progress and future prospects
Woias, P. (2005) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2004.02.033 · Cited by 371
Tuller, M., & Or, D. (2001) · Water Resources Research · doi:10.1029/2000wr900328 · Cited by 360
An Integrated Approach to a Portable and Low‐Cost Immunoassay for Resource‐Poor Settings
Sia, S. K., Linder, V., Parviz, B. A., Siegel, A., & Whitesides, G. M. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200353016 · Cited by 292
Hosokawa, K., Sato, K., Ichikawa, N., & Maeda, M. (2004) · Lab on a Chip · doi:10.1039/b403930k · Cited by 260
Microfluidics for Processing Surfaces and Miniaturizing Biological Assays
Delamarche, E., Juncker, D., & Schmid, H. (2005) · Advanced Materials · doi:10.1002/adma.200501129 · Cited by 251
Self-citationPermeation-driven flow in poly(dimethylsiloxane) microfluidic devices.
Randall, G. C., & Doyle, P. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503287102 · Cited by 220
High-sensitivity miniaturized immunoassays for tumor necrosis factor ? using microfluidic systems
Cesaro-Tadic, S., Dernick, G., Juncker, D., Buurman, G., Kropshofer, H., Michel, B., Fattinger, C., & Delamarche, E. (2004) · Lab on a Chip · doi:10.1039/b408964b · Cited by 203
Self-citationTowards numerical prototyping of labs-on-chip: modeling for integrated microfluidic devices
Erickson, D. (2005) · Microfluidics and Nanofluidics · doi:10.1007/s10404-005-0041-z · Cited by 175
Rise of Liquids and Bubbles in Angular Capillary Tubes
Bico, J., & Quéré, D. (2002) · Journal of Colloid and Interface Science · doi:10.1006/jcis.2001.8106 · Cited by 116
Continuous flow in open microfluidics using controlled evaporation
Zimmermann, M., Bentley, S., Schmid, H., Hunziker, P., & Delamarche, E. (2005) · Lab on a Chip · doi:10.1039/b510044e · Cited by 85
Self-citation
Cited by
Microfluidic Paper-Based Analytical Devices: From Design to Applications
Noviana, E., Ozer, T., Carrell, C. S., Link, J. S., McMahon, C., Jang, I., & Henry, C. S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01335 · Cited by 631
Capillary microfluidics in microchannels: from microfluidic networks to capillaric circuits
Olanrewaju, A., Beaugrand, M., Yafia, M., & Juncker, D. (2018) · Lab on a Chip · doi:10.1039/c8lc00458g · Cited by 451
Micro Total Analysis Systems: Latest Achievements
West, J., Becker, M., Tombrink, S., & Manz, A. (2008) · Analytical Chemistry · doi:10.1021/ac800680j · Cited by 423
Hang, Y., Boryczka, J., & Wu, N. (2022) · Chemical Society Reviews · doi:10.1039/c9cs00621d · Cited by 377
Gervais, L., & Delamarche, E. (2009) · Lab on a Chip · doi:10.1039/b906523g · Cited by 345
Self-citation
Metadata
- Authors
- Zimmermann, M., Schmid, H., Hunziker, P., & Delamarche, E.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2007
- Volume
- 7
- Issue
- 1
- Pages
- 119-125
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1986273109
- Cited by
- 380
- References
- 20
- FWCI
- 5.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.