The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Toward one-step point-of-care immunodiagnostics using capillary-driven microfluidics and PDMS substrates
Abstract
Point-of-care diagnostics will strongly benefit from miniaturization based on microfluidics because microfluidics integrate functions that can together preserve valuable samples and reagents, increase sensitivity of a test, and accelerate mass transport limited reactions. But a main challenge is to incorporate reagents into microfluidics and to make microfluidics simple to use. Here, we integrate microfluidic functional elements, some of which were developed earlier, and reagents such as detection antibodies (dAbs), capture antibodies (cAbs) and analyte molecules for making one-step immunoassays: the integrated device only requires the addition of sample to trigger a cascade of events powered by capillary forces for effecting a sandwich immunoassay that is read using a fluorescence microscope. The microfluidic elements comprise a sample collector, delay valves, flow resistors, a deposition zone for dAbs, a reaction chamber sealed with a polydimethylsiloxane (PDMS) substrate, and a capillary pump and vents. Parameters for depositing 3.6 nL of a solution of dAb on the chip using an inkjet are optimized and the PDMS substrate is patterned with analytes, which provide a positive control, and cAbs. Various storage conditions of the patterned PDMS are investigated for up to 6 months revealing that storage with a desiccant preserved at least 51% of the activity of the cAbs. C-reactive protein (CRP), a general inflammation and cardiac marker, is detected using this one-step chip using only 5 microL of human serum by measuring fluorescent signals from 30 x 100 microm(2) areas of the PDMS substrate in the wet reaction chamber. The one-step chip can detect CRP at a concentration of 10 ng mL(-1) in less than 3 min and below 1 ng mL(-1) within 14 min. The work presented here may spur the adoption of fluorescence immunoassays using capillary driven microfluidics and PDMS substrates for point-of-care diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
Microfluidic diagnostic technologies for global public health
Yager, P., Edwards, T., Fu, E., Helton, K., Nelson, K., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,979
Multiple Biomarkers for the Prediction of First Major Cardiovascular Events and Death
Wang, T. J., Gona, P., Larson, M. G., Tofler, G. H., Levy, D., Newton-Cheh, C., Jacques, P. F., Rifai, N., Selhub, J., Robins, S. J., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa055373 · Cited by 1,343
Sawyers, C. L. (2008) · Nature · doi:10.1038/nature06913 · Cited by 983
Mining the plasma proteome for cancer biomarkers
Hanash, S. M., Pitteri, S. J., & Faca, V. M. (2008) · Nature · doi:10.1038/nature06916 · Cited by 891
Lab-on-a-chip devices for global health: Past studies and future opportunities
Chin, C. D., Linder, V., & Sia, S. K. (2007) · Lab Chip · doi:10.1039/b611455e · Cited by 811
The autofluorescence of plastic materials and chips measured under laser irradiation
Piruska, A., Nikcevic, I., Lee, S. H., Ahn, C., Heineman, W. R., Limbach, P. A., & Seliskar, C. J. (2005) · Lab on a Chip · doi:10.1039/b508288a · Cited by 431
Autonomous Microfluidic Capillary System
Juncker, D., Schmid, H., Drechsler, U., Wolf, H., Wolf, M., Michel, B., de Rooij, N., & Delamarche, E. (2002) · Analytical Chemistry · doi:10.1021/ac0261449 · Cited by 426
Self-citationTackling heart failure in the twenty-first century
Mudd, J. O., & Kass, D. A. (2008) · Nature · doi:10.1038/nature06798 · Cited by 406
C-reactive protein: a valuable marker of sepsis
Póvoa, P. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1209-6 · Cited by 403
Cited by
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
High-Spatial-Resolution Multi-Omics Sequencing via Deterministic Barcoding in Tissue
Liu, Y., Yang, M., Deng, Y., Su, G., Enninful, A., Guo, C. C., Tebaldi, T., Zhang, D., Kim, D., Bai, Z., et al. (2020) · Cell · doi:10.1016/j.cell.2020.10.026 · Cited by 966
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Measurement of biomarker proteins for point-of-care early detection and monitoring of cancer
Rusling, J. F., Kumar, C. V., Gutkind, J. S., & Patel, V. (2010) · The Analyst · doi:10.1039/c0an00204f · Cited by 552
Metadata
- Authors
- Gervais, L., & Delamarche, E.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 9
- Issue
- 23
- Pages
- 3330
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2048616775
- Cited by
- 345
- References
- 23
- FWCI
- 14.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Toward one-step point-of-care immunodiagnostics using capillary-driven microfluidics and PDMS substrates. https://app.cochat.ai/papers/10.1039/b906523g
- The paper
- Gervais, L., & Delamarche, E. (2009). Toward one-step point-of-care immunodiagnostics using capillary-driven microfluidics and PDMS substrates. Lab on a Chip. https://doi.org/10.1039/b906523g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.