Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 345

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Toward one-step point-of-care immunodiagnostics using capillary-driven microfluidics and PDMS substrates

Gervais, Luc, Delamarche, Emmanuel·2009·Lab on a Chip

Abstract

Point-of-care diagnostics will strongly benefit from miniaturization based on microfluidics because microfluidics integrate functions that can together preserve valuable samples and reagents, increase sensitivity of a test, and accelerate mass transport limited reactions. But a main challenge is to incorporate reagents into microfluidics and to make microfluidics simple to use. Here, we integrate microfluidic functional elements, some of which were developed earlier, and reagents such as detection antibodies (dAbs), capture antibodies (cAbs) and analyte molecules for making one-step immunoassays: the integrated device only requires the addition of sample to trigger a cascade of events powered by capillary forces for effecting a sandwich immunoassay that is read using a fluorescence microscope. The microfluidic elements comprise a sample collector, delay valves, flow resistors, a deposition zone for dAbs, a reaction chamber sealed with a polydimethylsiloxane (PDMS) substrate, and a capillary pump and vents. Parameters for depositing 3.6 nL of a solution of dAb on the chip using an inkjet are optimized and the PDMS substrate is patterned with analytes, which provide a positive control, and cAbs. Various storage conditions of the patterned PDMS are investigated for up to 6 months revealing that storage with a desiccant preserved at least 51% of the activity of the cAbs. C-reactive protein (CRP), a general inflammation and cardiac marker, is detected using this one-step chip using only 5 microL of human serum by measuring fluorescent signals from 30 x 100 microm(2) areas of the PDMS substrate in the wet reaction chamber. The one-step chip can detect CRP at a concentration of 10 ng mL(-1) in less than 3 min and below 1 ng mL(-1) within 14 min. The work presented here may spur the adoption of fluorescence immunoassays using capillary driven microfluidics and PDMS substrates for point-of-care diagnostics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/b906523g

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

See all 345

Metadata

Authors
Gervais, L., & Delamarche, E.
Venue
Lab on a Chip
Published
2009
Volume
9
Issue
23
Pages
3330
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2048616775
Cited by
345
References
23
FWCI
14.95
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Toward one-step point-of-care immunodiagnostics using capillary-driven microfluidics and PDMS substrates. https://app.cochat.ai/papers/10.1039/b906523g
The paper
Gervais, L., & Delamarche, E. (2009). Toward one-step point-of-care immunodiagnostics using capillary-driven microfluidics and PDMS substrates. Lab on a Chip. https://doi.org/10.1039/b906523g

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.