The DOI matches its Crossref record.
Integrated continuous microfluidic liquid–liquid extraction
Abstract
We describe continuous flow liquid-liquid phase separation in microfluidic devices based on capillary forces and selective wetting surfaces. Effective liquid-liquid phase separation is achieved by using a thin porous fluoropolymer membrane that selectively wets non-aqueous solvents, has average pore sizes in the 0.1-1 microm range, and has a high pore density for high separation throughput. Pressure drops throughout the microfluidic network are modelled and operating regimes for the membrane phase separator are determined based on hydrodynamic pressure drops and capillary forces. A microfluidic extraction device integrating mixing and phase separation is realized by using silicon micromachining. Modeling of the phase separator establishes the operating limits. The device is capable of completely separating several organic-aqueous and fluorous-aqueous liquid-liquid systems, even with high fractions of partially miscible compounds. In each case, extraction is equivalent to one equilibrium extraction stage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The past, present and potential for microfluidic reactor technology in chemical synthesis
Elvira, K. S., i Solvas, X. C., Wootton, R. C. R., & deMello, A. J. (2013) · Nature Chemistry · doi:10.1038/nchem.1753 · Cited by 1,203
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049
Mascia, S., Heider, P. L., Zhang, H., Lakerveld, R., Benyahia, B., Barton, P. I., Braatz, R. D., Cooney, C. L., Evans, J. M. B., Jamison, T. F., et al. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201305429 · Cited by 599
Self-citationMicrochemical systems for continuous-flow synthesis
Hartman, R. L., & Jensen, K. F. (2009) · Lab on a Chip · doi:10.1039/b906343a · Cited by 508
Self-citationContinuous Flow Upgrading of Selected C2–C6Platform Chemicals Derived from Biomass
Gérardy, R., Debecker, D. P., Estager, J., Luis, P., & Monbaliu, J.-C. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00846 · Cited by 398
Metadata
- Authors
- Kralj, J. G., Sahoo, H. R., & Jensen, K. F.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2007
- Volume
- 7
- Issue
- 2
- Pages
- 256-263
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2068770175
- Cited by
- 380
- References
- 0
- FWCI
- 10.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Integrated continuous microfluidic liquid–liquid extraction. https://app.cochat.ai/papers/10.1039/b610888a
- The paper
- Kralj, J. G., Sahoo, H. R., & Jensen, K. F. (2007). Integrated continuous microfluidic liquid–liquid extraction. Lab Chip. https://doi.org/10.1039/b610888a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.