In vitro continuous amperometric monitoring of 5-hydroxytryptamine release from enterochromaffin cells of the guinea pig ileum
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A diamond microelectrode was used to sensitively, reproducibly and stably record overflow of 5-hydroxytryptamine (5-HT, serotonin) from enterochromaffin cells (EC) of the intenstinal mucosal layer. 5-HT is an important neurotransmitter and paracrine signalling molecule in the gastrointestinal tract. The diamond microelectrode was formed by overcoating a sharpened 76 microm diameter Pt wire with a thin layer of conducting diamond. After insulation with polypropylene, the conically-shaped microelectrode had a diameter of about 10 microm at the tip and 80 microm at the cylindrical portion. The exposed length was 100-200 microm. Continuous amperometry with the microelectrode poised at a detection potential of 700 mV vs. Ag|AgCl was used to measure 5-HT overflow as an oxidation current. 5-HT overflow was elicited by both mechanical and electrical stimulation. Some minor electrode fouling, a common problem with the oxidative detection of 5-HT, was seen for diamond but the response stabilized enabling recording in vitro. Both 5-HT and the paracrine hormone, melatonin, were detected in the extracellular solution. The 5-HT oxidation current increased in the presence of the serotonin transporter (SERT) inhibitor, fluoxetine (1 microM), providing evidence that the oxidation current was associated with 5-HT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chow, R. H., von Rüden, L., & Neher, E. (1992) · Nature · doi:10.1038/356060a0 · Cited by 817
Sensory mechanisms: transmitters, modulators and reflexes
Raybould, H. E., Cooke, H. J., & Christofi, F. L. (2004) · Neurogastroenterology & Motility · doi:10.1111/j.1743-3150.2004.00477.x · Cited by 90
Cited by
Serotonin signalling in the gut: functions, dysfunctions and therapeutic targets
Mawe, G. M., & Hoffman, J. M. (2013) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2013.105 · Cited by 1,165
5-Hydroxytryptamine (serotonin) in the gastrointestinal tract
Gershon, M. D. (2013) · Current Opinion in Endocrinology, Diabetes & Obesity · doi:10.1097/med.0b013e32835bc703 · Cited by 617
Conductive diamond: synthesis, properties, and electrochemical applications
Yang, N., Yu, S., Macpherson, J. V., Einaga, Y., Zhao, H., Zhao, G., Swain, G. M., & Jiang, X. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00757d · Cited by 522
Self-citationA tissue-like neurotransmitter sensor for the brain and gut
Li, J., Liu, Y., Yuan, L., Zhang, B., Bishop, E. S., Wang, K., Tang, J., Zheng, Y.-Q., Xu, W., Niu, S., et al. (2022) · Nature · doi:10.1038/s41586-022-04615-2 · Cited by 443
Electrochemical Monitoring of Single Cell Secretion: Vesicular Exocytosis and Oxidative Stress
Amatore, C., Arbault, S., Guille, M., & Lemaître, F. (2008) · Chemical Reviews · doi:10.1021/cr068062g · Cited by 406
Metadata
- Authors
- Patel, B. A., Bian, X., Quaiserová-Mocko, V., Galligan, J. J., & Swain, G. M.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2007
- Volume
- 132
- Issue
- 1
- Pages
- 41-47
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W1975183047
- Cited by
- 110
- References
- 2
- FWCI
- 4.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.