The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
A microfluidic device for practical label-free CD4+ T cell counting of HIV-infected subjects
Open accessAbstract
Practical HIV diagnostics are urgently needed in resource-limited settings. While HIV infection can be diagnosed using simple, rapid, lateral flow immunoassays, HIV disease staging and treatment monitoring require accurate counting of a particular white blood cell subset, the CD4(+) T lymphocyte. To address the limitations of current expensive, technically demanding and/or time-consuming approaches, we have developed a simple CD4 counting microfluidic device. This device uses cell affinity chromatography operated under differential shear flow to specifically isolate CD4(+) T lymphocytes with high efficiency directly from 10 microliters of unprocessed, unlabeled whole blood. CD4 counts are obtained under an optical microscope in a rapid, simple and label-free fashion. CD4 counts determined in our device matched measurements by conventional flow cytometry among HIV-positive subjects over a wide range of absolute CD4 counts (R(2) = 0.93). This CD4 counting microdevice can be used for simple, rapid and affordable CD4 counting in point-of-care and resource-limited settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guidelines for the Use of Antiretroviral Agents in HIV-Infected Adults and Adolescents
(1998) · Annals of Internal Medicine · doi:10.7326/0003-4819-128-12_part_2-199806151-00003 · Cited by 5,209
Castro, K. G., Ward, J. W., Slutsker, L., Buehler, J. W., Jaffe, H. W., Berkelman, R. L., & Curran, J. W. (1993) · Clinical Infectious Diseases · doi:10.1093/clinids/17.4.802 · Cited by 4,349
Plasma Viral Load and CD4+ Lymphocytes as Prognostic Markers of HIV-1 Infection
Mellors, J. W., Munoz, A., Giorgi, J. V., Margolick, J. B., Tassoni, C. J., Gupta, P., Kingsley, L. A., Todd, J. A., Saah, A. J., Detels, R., et al. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-126-12-199706150-00003 · Cited by 2,067
Hinterdorfer, P., Baumgartner, W., Gruber, H. J., Schilcher, K., & Schindler, H. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.8.3477 · Cited by 1,170
(1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1993.03500040022009 · Cited by 958
Changes in Plasma HIV-1 RNA and CD4+ Lymphocyte Counts and the Risk of Progression to AIDS
O'Brien, W. A., Hartigan, P. M., Martin, D., Esinhart, J., Hill, A., Benoit, S., Rubin, M., Simberkoff, M. S., & Hamilton, J. D. (1996) · New England Journal of Medicine · doi:10.1056/nejm199602153340703 · Cited by 720
Microfluidic devices for cellomics: a review
Andersson, H., & van den Berg, A. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(03)00266-1 · Cited by 661
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Self-citationLee, B., Sharron, M., Montaner, L. J., Weissman, D., & Doms, R. W. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.9.5215 · Cited by 579
Microfluidics technology for manipulation and analysis of biological cells
Yi, C., Li, C.-W., Ji, S., & Yang, M. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.12.037 · Cited by 478
Clerici, M., Hakim, F. T., Venzon, D. J., Blatt, S., Hendrix, C. W., Wynn, T. A., & Shearer, G. M. (1993) · Journal of Clinical Investigation · doi:10.1172/jci116294 · Cited by 469
Amiji, M., & Park, K. (1993) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856293x00537 · Cited by 346
Design and construction of a linear shear stress flow chamber
Usami, S., Chen, H.-H., Zhao, Y., Chien, S., & Skalak, R. (1993) · Annals of Biomedical Engineering · doi:10.1007/bf02368167 · Cited by 311
O'Brien, W. A., Hartigan, P. M., Daar, E. S., Simberkoff, M. S., & Hamilton, J. D. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-126-12-199706150-00002 · Cited by 259
Margination of leukocytes in blood flow through small tubes
Goldsmith, H. L., & Spain, S. (1984) · Microvascular Research · doi:10.1016/0026-2862(84)90054-2 · Cited by 239
Microfabricated devices in biotechnology and biochemical processing
Chován, T., & Guttman, A. (2002) · Trends in Biotechnology · doi:10.1016/s0167-7799(02)01905-4 · Cited by 229
Biomimetic Autoseparation of Leukocytes from Whole Blood in a Microfluidic Device
Shevkoplyas, S. S., Yoshida, T., Munn, L. L., & Bitensky, M. W. (2005) · Analytical Chemistry · doi:10.1021/ac049037i · Cited by 225
A Microchip CD4 Counting Method for HIV Monitoring in Resource-Poor Settings
Rodriguez, W. R., Christodoulides, N., Floriano, P. N., Graham, S., Mohanty, S., Dixon, M., Hsiang, M., Peter, T., Zavahir, S., Thior, I., et al. (2005) · PLoS Medicine · doi:10.1371/journal.pmed.0020182 · Cited by 196
Self-citationvon SYDOW, M., SÖNNERBORG, A., GAINES, H., & STRANNEGÅRD, Ö. (1991) · AIDS Research and Human Retroviruses · doi:10.1089/aid.1991.7.375 · Cited by 195
Microchip-based chemical and biochemical analysis systems
Sato, K., Hibara, A., Tokeshi, M., Hisamoto, H., & Kitamori, T. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00225-9 · Cited by 165
Effect of Flow and Surface Conditions on Human Lymphocyte Isolation Using Microfluidic Chambers
Murthy, S. K., Sin, A., Tompkins, R. G., & Toner, M. (2004) · Langmuir · doi:10.1021/la048047b · Cited by 144
Self-citationAnderson, S. J., Shugars, D. C., Swanstrom, R. I., & Garcia, J. V. (1993) · Journal of Virology · doi:10.1128/jvi.67.8.4923-4931.1993 · Cited by 132
Thali, M., Furman, C., Helseth, E., Repke, H., & Sodroski, J. (1992) · Journal of Virology · doi:10.1128/jvi.66.9.5516-5524.1992 · Cited by 91
Sin, A., Murthy, S. K., Revzin, A., Tompkins, R. G., & Toner, M. (2005) · Biotechnology and Bioengineering · doi:10.1002/bit.20556 · Cited by 85
Self-citationPerformance evaluation of the FACSCount system: A dedicated system for clinical cellular analysis
Strauss, K. W., Hannet, I., Engels, S., Shiba, A. S., Ward, D. M., Ullery, S., Jinguji, M. G., Valinsky, J. E., Barnett, D. B., Orfao, A., et al. (1996) · Cytometry · doi:10.1002/(sici)1097-0320(19960315)26:1<52::aid-cyto8>3.0.co;2-i · Cited by 84
Absolute CD4 T-Cell Counting in Resource-Poor Settings
Dièye, T. N., Vereecken, C., Diallo, A. A., Ondoa, P., Diaw, P. A., Camara, M., Karam, F., Mboup, S., & Kestens, L. (2005) · JAIDS Journal of Acquired Immune Deficiency Syndromes · doi:10.1097/01.qai.0000160515.20581.ad · Cited by 66
Longitudinal analysis of serum chemokine levels in the course of HIV-1 infection
Polo, S., Veglia, F., Malnati, M., et al. (1999) · AIDS · doi:10.1097/00002030-199903110-00002 · Cited by 57
Evaluation of the FACScount, TRAx CD4 and Dynabeads methods for CD4 lymphocyte determination
Lyamuya, E., Kagoma, C., Mbena, E., Urassa, W. K., Pallangyo, K., Mhalu, F. S., & Biberfeld, G. (1996) · Journal of Immunological Methods · doi:10.1016/0022-1759(96)00094-4 · Cited by 54
Trial, J., Birdsall, H. H., Hallum, J. A., Crane, M. L., Rodriguez‐Barradas, M. C., de Jong, A. L., Krishnan, B., Lacke, C. E., Figdor, C. G., & Rossen, R. D. (1995) · Journal of Clinical Investigation · doi:10.1172/jci117845 · Cited by 49
Balakrishnan, P., Dunne, M. C. M., Kumarasamy, N., Crowe, S. M., Subbulakshmi, G., Ganesh, A. K., Cecelia, A. J., Roth, P., Mayer, K. H., Thyagarajan, S. P., et al. (2004) · JAIDS Journal of Acquired Immune Deficiency Syndromes · doi:10.1097/00126334-200408150-00002 · Cited by 47
Diagbouga, S. P., Durand, G., Sanou, P. T., Dahourou, H., & Ledru, É. (1999) · Tropical Medicine & International Health · doi:10.1046/j.1365-3156.1999.00362.x · Cited by 21
Monocyte Activation by Circulating Fibronectin Fragments in HIV-1-Infected Patients
Trial, J., Rubio, J. A., Birdsall, H. H., Rodriguez‐Barradas, M. C., & Rossen, R. D. (2004) · The Journal of Immunology · doi:10.4049/jimmunol.173.3.2190 · Cited by 17
Cited by
Commercialization of microfluidic point-of-care diagnostic devices
Chin, C. D., Linder, V., & Sia, S. K. (2012) · Lab on a Chip · doi:10.1039/c2lc21204h · Cited by 1,124
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Wyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Engineering Hydrogels as Extracellular Matrix Mimics
Geckil, H., Xu, F., Zhang, X., Moon, S., & Demirci, U. (2010) · Nanomedicine · doi:10.2217/nnm.10.12 · Cited by 944
Self-citationAptamers from Cell-Based Selection for Bioanalytical Applications
Tan, W., Donovan, M. J., & Jiang, J. (2013) · Chemical Reviews · doi:10.1021/cr300468w · Cited by 649
Metadata
- Authors
- Cheng, X., Irimia, D., Dixon, M., Sekine, K., Demirci, U., Zamir, L., Tompkins, R. G., Rodriguez, W., & Toner, M.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2007
- Volume
- 7
- Issue
- 2
- Pages
- 170-178
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2100898839
- Cited by
- 340
- References
- 32
- FWCI
- 13.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.