The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Quantitative detection of protein expression in single cells using droplet microfluidics
Abstract
We demonstrate that single cells can be controllably compartmentalized within aqueous microdroplets; using such an approach we perform high-throughput screening by detecting the expression of a fluorescent protein in individual cells with simultaneous measurement of droplet size and cell occupancy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nagai, T., Ibata, K., Park, E. S., Kubota, M., Mikoshiba, K., & Miyawaki, A. (2002) · Nature Biotechnology · doi:10.1038/nbt0102-87 · Cited by 2,753
A Microfluidic System for Controlling Reaction Networks in Time
Song, H., Tice, J. D., & Ismagilov, R. F. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390203 · Cited by 1,082
Man-made cell-like compartments for molecular evolution
Tawfik, D. S., & Griffiths, A. D. (1998) · Nature Biotechnology · doi:10.1038/nbt0798-652 · Cited by 956
He, M., Edgar, J. S., Jeffries, G. D. M., Lorenz, R. M., Shelby, J. P., & Chiu, D. T. (2005) · Analytical Chemistry · doi:10.1021/ac0480850 · Cited by 518
Microfluidic systems for chemical kinetics that rely on chaotic mixing in droplets
Bringer, M. R., Gerdts, C. J., Song, H., Tice, J. D., & Ismagilov, R. F. (2004) · Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2003.1364 · Cited by 416
Miniaturising the laboratory in emulsion droplets
Griffiths, A. D., & Tawfik, D. S. (2006) · Trends in Biotechnology · doi:10.1016/j.tibtech.2006.06.009 · Cited by 346
Directed evolution of an extremely fast phosphotriesterase by in vitro compartmentalization
Griffiths, A. D. (2003) · The EMBO Journal · doi:10.1093/emboj/cdg014 · Cited by 321
Microfluidics-based systems biology
Breslauer, D. N., Lee, P. J., & Lee, L. P. (2006) · Molecular BioSystems · doi:10.1039/b515632g · Cited by 303
Controlled Microfluidic Encapsulation of Cells, Proteins, and Microbeads in Lipid Vesicles
Tan, Y.-C., Hettiarachchi, K., Siu, M., Pan, Y.-R., & Lee, A. P. (2006) · Journal of the American Chemical Society · doi:10.1021/ja056641h · Cited by 278
Aharoni, A., Amitai, G., Bernath, K., Magdassi, S., & Tawfik, D. S. (2005) · Chemistry & Biology · doi:10.1016/j.chembiol.2005.09.012 · Cited by 225
Directed evolution by in vitro compartmentalization
Miller, O. J., Bernath, K., Agresti, J. J., Amitai, G., Kelly, B. T., Mastrobattista, E., Taly, V., Magdassi, S., Tawfik, D. S., & Griffiths, A. D. (2006) · Nature Methods · doi:10.1038/nmeth897 · Cited by 210
Bernath, K., Hai, M., Mastrobattista, E., Griffiths, A. D., Magdassi, S., & Tawfik, D. S. (2004) · Analytical Biochemistry · doi:10.1016/j.ab.2003.10.005 · Cited by 165
Varadarajan, N., Gam, J., Olsen, M. J., Georgiou, G., & Iverson, B. L. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0500063102 · Cited by 163
New genotype–phenotype linkages for directed evolution of functional proteins
Leemhuis, H., Stein, V., Griffiths, A. D., & Hollfelder, F. (2005) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2005.07.006 · Cited by 126
Self-citationCohen, H. M., Tawfik, D. S., & Griffiths, A. D. (2004) · Protein Engineering Design and Selection · doi:10.1093/protein/gzh001 · Cited by 112
Chen, D. L., & Ismagilov, R. F. (2006) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2006.04.004 · Cited by 96
Flow Cytometry: A New Method To Investigate the Properties of Water-in-Oil-in-Water Emulsions
Hai, M., Bernath-Levin, K., Tawfik, D. S., & Magdassi, S. (2004) · Langmuir · doi:10.1021/la035402+ · Cited by 40
Cited by
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Single-cell analysis and sorting using droplet-based microfluidics
Mazutis, L., Gilbert, J., Ung, W. L., Weitz, D. A., Griffiths, A. D., & Heyman, J. A. (2013) · Nature Protocols · doi:10.1038/nprot.2013.046 · Cited by 1,355
Ultrahigh-throughput screening in drop-based microfluidics for directed evolution
Agresti, J. J., Antipov, E., Abate, A. R., Ahn, K., Rowat, A. C., Baret, J.-C., Marquez, M., Klibanov, A. M., Griffiths, A. D., & Weitz, D. A. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910781107 · Cited by 1,149
Droplet microfluidic technology for single-cell high-throughput screening
Brouzes, E., Medkova, M., Savenelli, N., Marran, D., Twardowski, M., Hutchison, J. B., Rothberg, J. M., Link, D. R., Perrimon, N., & Samuels, M. L. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0903542106 · Cited by 1,069
Metadata
- Authors
- Huebner, A., Srisa-Art, M., Holt, D., Abell, C., Hollfelder, F., deMello, A. J., & Edel, J. B.
- Venue
- Chemical Communications
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2007
- Issue
- 12
- Pages
- 1218
- ISSN
- 1359-7345 (ISSN-L)
- 1364-548X
- OpenAlex
- W2030782592
- Cited by
- 370
- References
- 17
- FWCI
- 22.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.