Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 245

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Cu–ATSM: A radiopharmaceutical for the PET imaging of hypoxia

Vāvere, Amy L., Lewis, Jason S.·2007·Dalton Transactions

Abstract

Copper(II)-diacetyl-bis(N(4)-methylthiosemicarbazone), Cu-ATSM, labeled with a positron emitting isotope of copper ((60)Cu, (61)Cu, (62)Cu or (64)Cu) has been shown, in vitro and in vivo, to be selective for hypoxic tissue. In silico studies have explored the mechanism of its hypoxia selectivity, and clinical studies with this agent have shown non-invasive imaging data that is predictive of a cancer patients' response to conventional therapy. This Perspective discusses the evolution of Cu-ATSM, how its selectivity can be improved upon, and where this metal-ligand platform could be taken in the future.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/b705989b

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 245

Metadata

Authors
Vāvere, A. L., & Lewis, J. S.
Venue
Dalton Transactions
Published
2007
Issue
43
Pages
4893
ISSN
  • 1477-9226 (ISSN-L)
  • 1477-9234
OpenAlex
W2155258338
Cited by
245
References
2
FWCI
11.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cu–ATSM: A radiopharmaceutical for the PET imaging of hypoxia. https://app.cochat.ai/papers/10.1039/b705989b
The paper
Vāvere, A. L., & Lewis, J. S. (2007). Cu–ATSM: A radiopharmaceutical for the PET imaging of hypoxia. Dalton Transactions. https://doi.org/10.1039/b705989b

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.