Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 191

The DOI matches its Crossref record.

Flow rate analysis of a surface tension driven passive micropump

Berthier, Erwin, Beebe, David J.·2007·Lab on a Chip

Abstract

A microfluidic passive pumping method relying on surface tension properties is investigated and a physical model is developed. When a small inlet drop is placed on the entrance of a microfluidic channel it creates more pressure than a large output drop at the channel exit, causing fluid flow. The behavior of the input drop occurs in two characteristic phases. An analytical solution is proposed and verified by experimental results. We find that during the first phase the flow rate is stable and that this phase can be prolonged by refilling the inlet drop to produce continuous flow in the microchannel.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/b707637a

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 191

Metadata

Authors
Berthier, E., & Beebe, D. J.
Venue
Lab on a Chip
Published
2007
Volume
7
Issue
11
Pages
1475
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2129980663
Cited by
191
References
0
FWCI
10.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Flow rate analysis of a surface tension driven passive micropump. https://app.cochat.ai/papers/10.1039/b707637a
The paper
Berthier, E., & Beebe, D. J. (2007). Flow rate analysis of a surface tension driven passive micropump. Lab on a Chip. https://doi.org/10.1039/b707637a

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.