The DOI matches its Crossref record.
Hydrodynamically tunable optofluidic cylindrical microlens
Abstract
In this work, we report the design, fabrication, and characterization of a tunable optofluidic microlens that focuses light within a microfluidic device. The microlens is generated by the interface of two co-injected miscible fluids of different refractive indices, a 5 M CaCl(2) solution (n(D) = 1.445) and deionized (DI) water (n(D) = 1.335). When the liquids flow through a 90-degree curve in a microchannel, a centrifugal effect causes the fluidic interface to be distorted and the CaCl(2) solution bows outwards into the DI water portion. The bowed fluidic interface, coupled with the refractive index contrast between the two fluids, yields a reliable cylindrical microlens. The optical characteristics of the microlens are governed by the shape of the fluidic interface, which can be altered by simply changing the flow rate. Higher flow rates generate a microlens with larger curvature and hence shorter focal length. The changing of microlens profile is studied using both computational fluid dynamics (CFD) and confocal microscopy. The focusing effect is experimentally characterized through intensity measurements and image analysis of the focused light beam, and the experimental data are further confirmed by the results from a ray-tracing optical simulation. Our investigation reveals a simple, robust, and effective mechanism for integrating optofluidic tunable microlenses in lab-on-a-chip systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Di Carlo, D. (2009) · Lab on a Chip · doi:10.1039/b912547g · Cited by 1,627
Surface acoustic wave microfluidics
Ding, X., Li, P., Lin, S.-C. S., Stratton, Z. S., Nama, N., Guo, F., Slotcavage, D., Mao, X., Shi, J., Costanzo, F., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50361e · Cited by 926
Self-citationAcoustic tweezers: patterning cells and microparticles using standing surface acoustic waves (SSAW)
Shi, J., Ahmed, D., Mao, X., Lin, S.-C. S., Lawit, A., & Huang, T. J. (2009) · Lab on a Chip · doi:10.1039/b910595f · Cited by 723
Self-citationAmini, H., Lee, W., & Di Carlo, D. (2014) · Lab on a Chip · doi:10.1039/c4lc00128a · Cited by 722
Focusing microparticles in a microfluidic channel with standing surface acoustic waves (SSAW)
Shi, J., Mao, X., Ahmed, D., Colletti, A., & Huang, T. J. (2008) · Lab Chip · doi:10.1039/b716321e · Cited by 439
Self-citationA millisecond micromixer via single-bubble-based acoustic streaming
Ahmed, D., Mao, X., Shi, J., Juluri, B. K., & Huang, T. J. (2009) · Lab on a Chip · doi:10.1039/b903687c · Cited by 415
Self-citationMicrofluidics for medical diagnostics and biosensors
Rivet, C., Lee, H., Hirsch, A., Hamilton, S., & Lu, H. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2010.08.015 · Cited by 356
An acoustofluidic micromixer based on oscillating sidewall sharp-edges
Huang, P.-H., Xie, Y., Ahmed, D., Rufo, J., Nama, N., Chen, Y., Chan, C. Y., & Huang, T. J. (2013) · Lab on a Chip · doi:10.1039/c3lc50568e · Cited by 288
Self-citationOptofluidics for energy applications
Erickson, D., Sinton, D., & Psaltis, D. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.209 · Cited by 277
A fast microfluidic mixer based on acoustically driven sidewall-trapped microbubbles
Ahmed, D., Mao, X., Juluri, B. K., & Huang, T. J. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0444-3 · Cited by 272
Self-citation
Metadata
- Authors
- Mao, X., Waldeisen, J. R., Juluri, B. K., & Huang, T. J.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2007
- Volume
- 7
- Issue
- 10
- Pages
- 1303
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2017423256
- Cited by
- 172
- References
- 0
- FWCI
- 17.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.