The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
An improved sensitivity non-enzymatic glucose sensor based on a CuO nanowire modified Cu electrode
Abstract
CuO nanowires have been prepared and applied for the fabrication of glucose sensors with highly enhanced sensitivity. Cu(OH)(2) nanowires were initially synthesised by a simple and fast procedure, CuO nanowires were then formed simply by removing the water through heat treatment. The structures and morphologies of Cu(OH)(2) and CuO nanowires were characterised by X-ray diffraction, X-ray photoelectron spectroscopy, scanning electron microscopy, and transmission electron microscopy. The direct electrocatalytic oxidation of glucose in alkaline medium at CuO nanowire modified electrodes has been investigated in detail. Compared to a bare Cu electrode, a substantial decrease in the overvoltage of the glucose oxidation was observed at the CuO nanowire electrodes with oxidation starting at ca. 0.10 V vs. Ag/AgCl (saturated KCl). At an applied potential of 0.33 V, CuO nanowire electrodes produce high and reproducible sensitivity to glucose with 0.49 microA/micromol dm(-3). Linear responses were obtained over a concentration range from 0.40 micromol dm(-3) to 2.0 mmol dm(-3) with a detection limit of 49 nmol dm(-3) (S/N = 3). The CuO nanowire modified electrode allows highly sensitive, low working potential, stable, and fast amperometric sensing of glucose, thus is promising for the future development of non-enzymatic glucose sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yin, M., Wu, C.-K., Lou, Y., Burda, C., Koberstein, J. T., Zhu, Y., & O'Brien, S. (2005) · Journal of the American Chemical Society · doi:10.1021/ja050006u · Cited by 986
Nonenzymatic Glucose Detection Using Mesoporous Platinum
Park, S., Chung, T. D., & Kim, H. C. (2003) · Analytical Chemistry · doi:10.1021/ac0263465 · Cited by 594
Kang, X., Mai, Z., Zou, X., Cai, P., & Mo, J. (2007) · Analytical Biochemistry · doi:10.1016/j.ab.2007.01.003 · Cited by 572
Li, Y., Song, Y.-Y., Yang, C., & Xia, X.-H. (2007) · Electrochemistry Communications · doi:10.1016/j.elecom.2006.11.035 · Cited by 515
Highly Ordered Platinum‐Nanotubule Arrays for Amperometric Glucose Sensing
Yuan, J. H., Wang, K., & Xia, X. H. (2005) · Advanced Functional Materials · doi:10.1002/adfm.200400321 · Cited by 432
Kinetics and mechanism of glucose electrooxidation on different electrode-catalysts
Vassilyev, Y. B., Khazova, O. A., & Nikolaeva, N. N. (1985) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/0022-0728(85)85084-1 · Cited by 422
Single‐Crystalline Scroll‐Type Nanotube Arrays of Copper Hydroxide Synthesized at Room Temperature
Zhang, W., Wen, X., Yang, S., Berta, Y., & Wang, Z. L. (2003) · Advanced Materials · doi:10.1002/adma.200304840 · Cited by 381
Simple Template-Free Solution Route for the Controlled Synthesis of Cu(OH)2 and CuO Nanostructures
Lu, C., Qi, L., Yang, J., Zhang, D., Wu, N., & Ma, J. (2004) · The Journal of Physical Chemistry B · doi:10.1021/jp046772p · Cited by 338
Nonenzymatic glucose detection using multi-walled carbon nanotube electrodes
Ye, J.-S., Wen, Y., De Zhang, W., Ming Gan, L., Xu, G. Q., & Sheu, F.-S. (2004) · Electrochemistry Communications · doi:10.1016/j.elecom.2003.10.013 · Cited by 325
Combinatorial Discovery of Alloy Electrocatalysts for Amperometric Glucose Sensors
Sun, Y., Buck, H., & Mallouk, T. E. (2001) · Analytical Chemistry · doi:10.1021/ac0015117 · Cited by 306
Cited by
A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
Jiang, L.-C., & Zhang, W.-D. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.10.038 · Cited by 667
Non-enzymatic electrochemical sensing of glucose
Wang, G., He, X., Wang, L., Gu, A., Huang, Y., Fang, B., Geng, B., & Zhang, X. (2013) · Microchimica Acta · doi:10.1007/s00604-012-0923-1 · Cited by 522
Advances in non-enzymatic glucose sensors based on metal oxides
Zhu, H., Li, L., Zhou, W., Shao, Z., & Chen, X. (2016) · Journal of Materials Chemistry B · doi:10.1039/c6tb02037b · Cited by 473
CuO Nanospheres Based Nonenzymatic Glucose Sensor
Reitz, E., Jia, W., Gentile, M., Wang, Y., & Lei, Y. (2008) · Electroanalysis · doi:10.1002/elan.200804327 · Cited by 346
Ultrasensitive and selective non-enzymatic glucose detection using copper nanowires
Zhang, Y., Su, L., Manuzzi, D., de los Monteros, H. V. E., Jia, W., Huo, D., Hou, C., & Lei, Y. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.11.006 · Cited by 321
Karikalan, N., Karthik, R., Chen, S.-M., Karuppiah, C., & Elangovan, A. (2017) · Scientific Reports · doi:10.1038/s41598-017-02479-5 · Cited by 319
Three-dimensional network films of electrospun copper oxide nanofibers for glucose determination
Wang, W., Zhang, L., Tong, S., Li, X., & Song, W. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.08.013 · Cited by 310
CuO nanowires based sensitive and selective non-enzymatic glucose detection
Zhang, Y., Liu, Y., Su, L., Zhang, Z., Huo, D., Hou, C., & Lei, Y. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.08.096 · Cited by 260
Rajaji, U., Ganesh, P.-S., Chen, S.-M., Govindasamy, M., Kim, S.-Y., A. Alshgari, R., & Shimoga, G. (2021) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2021.07.015 · Cited by 42
Singh, B., & Dempsey, E. (2012) · ECS Journal of Solid State Science and Technology · doi:10.1149/2.003203jss · Cited by 7
Metadata
- Authors
- Zhuang, Z., Su, X., Yuan, H., Sun, Q., Xiao, D., & Choi, M. M. F.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 133
- Issue
- 1
- Pages
- 126-132
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W1983361712
- Cited by
- 481
- References
- 29
- FWCI
- 17.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.