A microfluidics-based turning assay reveals complex growth cone responses to integrated gradients of substrate-bound ECM molecules and diffusible guidance cues
The DOI matches its Crossref record.
Abstract
Neuronal growth cones contain sophisticated molecular machinery precisely regulating their migration in response to complex combinatorial gradients of diverse external cues. The details of this regulation are still largely unknown, in part due to limitations of the currently available experimental techniques. Microfluidic devices have been shown to be capable of generating complex, stable and precisely controlled chemical gradients, but their use in studying growth cone migration has been limited in part due to the effects of shear stress. Here we describe a microfluidics-based turning-assay chip designed to overcome this issue. In addition to generating precise gradients of soluble guidance cues, the chip can also fabricate complex composite gradients of diffusible and surface-bound guidance cues that mimic the conditions the growth cones realistically counter in vivo. Applying this assay to Xenopus embryonic spinal neurons, we demonstrate that the presence of a surface-bound laminin gradient can finely tune the polarity of growth cone responses (repulsion or attraction) to gradients of brain-derived neurotrophic factor (BDNF), with the guidance outcome dependent on the mean BDNF concentration. The flexibility inherent in this assay holds significant potential for refinement of our understanding of nervous system development and regeneration, and can be extended to elucidate other cellular processes involving chemotaxis of shear sensitive cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
RETRACTED: A mathematical model explains saturating axon guidance responses to molecular gradients
Nguyen, H., Dayan, P., Pujic, Z., Cooper-White, J., & Goodhill, G. J. (2016) · eLife · doi:10.7554/elife.12248 · Cited by 1,221
RetractedThe trip of the tip: understanding the growth cone machinery
Lowery, L. A., & Vactor, D. V. (2009) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2679 · Cited by 790
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Nanomaterials for Neural Interfaces
Kotov, N. A., Winter, J. O., Clements, I. P., Jan, E., Timko, B. P., Campidelli, S., Pathak, S., Mazzatenta, A., Lieber, C. M., Prato, M., et al. (2009) · Advanced Materials · doi:10.1002/adma.200801984 · Cited by 504
A multi-layer microfluidic device for efficient culture and analysis of renal tubular cells
Jang, K.-J., & Suh, K.-Y. (2010) · Lab Chip · doi:10.1039/b907515a · Cited by 497
Microengineered Platforms for Cell Mechanobiology
Kim, D.-H., Wong, P. K., Park, J., Levchenko, A., & Sun, Y. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124915 · Cited by 411
Self-citationBiological applications of microfluidic gradient devices
Kim, S., Kim, H. J., & Jeon, N. L. (2010) · Integrative Biology · doi:10.1039/c0ib00055h · Cited by 366
Concentration gradient generation methods based on microfluidic systems
Wang, X., Liu, Z., & Pang, Y. (2017) · RSC Advances · doi:10.1039/c7ra04494a · Cited by 219
A convection-driven long-range linear gradient generator with dynamic control
Wang, H., Chen, C.-H., Xiang, Z., Wang, M., & Lee, C. (2015) · Lab on a Chip · doi:10.1039/c4lc01451k · Cited by 40
Metadata
- Authors
- Joanne Wang, C., Li, X., Lin, B., Shim, S., Ming, G.-L., & Levchenko, A.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 8
- Issue
- 2
- Pages
- 227
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2060392968
- Cited by
- 140
- References
- 0
- FWCI
- 6.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.