The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
The surface of neat water is basic
Abstract
Theoretical studies which conclude that the surface of neat water is acidic (with a pH < or = 4.8), due to the preferential adsorption of hydronium ions, are contrary to the available experimental evidence. Air bubbles in water have a negative charge, as do hydrophobic oil drops in water, and streaming potential measurements on inert surfaces such as Teflon in water show a similar negative surface charge. In each case the pH dependence of the zeta potential has an isoelectric point between pH 2-4. An isoelectric point of pH 4 implies a preference for hydroxide over protons of 10(6), the opposite of what was inferred from the theoretical simulations. Water behaves similarly at all inert hydrophobic interfaces with the preferential adsorption of hydroxide ions to give a negatively charged surface at neutral pH. The surface-charge density at the oil/water interface in mM salt solutions is -5 to -7 microC cm(-2), which corresponds to one hydroxide ion on every 3 nm2 of the surface. The homogenisation of an inert oil such as hexadecane in water in the absence of any salt or base still leads to formation of an emulsion. The hydroxide adsorbed on the large surface area of the emulsion greatly exceeds that present at 10(-7) M in neutral water; it is created by the increased autolysis of water, driven by the strong adsorption of hydroxide ions at the oil/water interface. These surfactant-free, salt-free emulsions are stable for some hours, with protons as the only counterions to the negative hydroxide surface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ζ Potential of Microbubbles in Aqueous Solutions: Electrical Properties of the Gas−Water Interface
Takahashi, M. (2005) · The Journal of Physical Chemistry B · doi:10.1021/jp0445270 · Cited by 888
Charging of Oil−Water Interfaces Due to Spontaneous Adsorption of Hydroxyl Ions
Marinova, K. G., Alargova, R. G., Denkov, N. D., Velev, O. D., Petsev, D. N., Ivanov, I. B., & Borwankar, R. P. (1996) · Langmuir · doi:10.1021/la950928i · Cited by 836
The Pristine Oil/Water Interface: Surfactant‐Free Hydroxide‐Charged Emulsions
Beattie, J. K., & Djerdjev, A. M. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200453916 · Cited by 413
Self-citationBuch, V., Milet, A., Vácha, R., Jungwirth, P., & Devlin, J. P. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0611285104 · Cited by 398
An ab Initio Molecular Dynamics Study of the Aqueous Liquid-Vapor Interface
Kuo, I.-F. W., & Mundy, C. J. (2004) · Science · doi:10.1126/science.1092787 · Cited by 356
Karraker, K. A., & Radke, C. J. (2002) · Advances in Colloid and Interface Science · doi:10.1016/s0001-8686(01)00083-5 · Cited by 308
Zimmermann, R., Dukhin, S., & Werner, C. (2001) · The Journal of Physical Chemistry B · doi:10.1021/jp004051u · Cited by 261
The ζ-Potential of Gas Bubbles
Graciaa, A., Morel, G., Saulner, P., Lachaise, J., & Schechter, R. S. (1995) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1995.1234 · Cited by 237
Spectroscopic Studies of Solvated Hydrogen and Hydroxide Ions at Aqueous Surfaces
Tarbuck, T. L., Ota, S. T., & Richmond, G. L. (2006) · Journal of the American Chemical Society · doi:10.1021/ja063184b · Cited by 200
Autoionization at the surface of neat water: is the top layer pH neutral, basic, or acidic?
Vácha, R., Buch, V., Milet, A., Devlin, J. P., & Jungwirth, P. (2007) · Physical Chemistry Chemical Physics · doi:10.1039/b704491g · Cited by 178
Cited by
From contact electrification to triboelectric nanogenerators
Wang, Z. L. (2021) · Reports on Progress in Physics · doi:10.1088/1361-6633/ac0a50 · Cited by 553
RetractedProtons and Hydroxide Ions in Aqueous Systems
Agmon, N., Bakker, H. J., Campen, R. K., Henchman, R. H., Pohl, P., Roke, S., Thämer, M., & Hassanali, A. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00736 · Cited by 538
Strong Electric Field Observed at the Interface of Aqueous Microdroplets
Xiong, H., Lee, J. K., Zare, R. N., & Min, W. (2020) · The Journal of Physical Chemistry Letters · doi:10.1021/acs.jpclett.0c02061 · Cited by 485
Molecular reactions at aqueous interfaces
Ruiz-Lopez, M. F., Francisco, J. S., Martins-Costa, M. T. C., & Anglada, J. M. (2020) · Nature Reviews Chemistry · doi:10.1038/s41570-020-0203-2 · Cited by 411
Wood, R. J., Lee, J., & Bussemaker, M. J. (2017) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2017.03.030 · Cited by 340
The Orientation and Charge of Water at the Hydrophobic Oil Droplet–Water Interface
Vácha, R., Rick, S. W., Jungwirth, P., de Beer, A. G. F., de Aguiar, H. B., Samson, J.-S., & Roke, S. (2011) · Journal of the American Chemical Society · doi:10.1021/ja202081x · Cited by 278
Condensing water vapor to droplets generates hydrogen peroxide
Lee, J. K., Han, H. S., Chaikasetsin, S., Marron, D. P., Waymouth, R. M., Prinz, F. B., & Zare, R. N. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2020158117 · Cited by 267
Hydroxide and hydronium ion adsorption — A survey
Zimmermann, R., Freudenberg, U., Schweiß, R., Küttner, D., & Werner, C. (2010) · Current Opinion in Colloid & Interface Science · doi:10.1016/j.cocis.2010.01.002 · Cited by 261
Metadata
- Authors
- Beattie, J. K., Djerdjev, A. M., & Warr, G. G.
- Venue
- Faraday Discuss.
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 141
- Pages
- 31-39
- ISSN
- 1359-6640 (ISSN-L)
- 1364-5498
- OpenAlex
- W2120298192
- Cited by
- 337
- References
- 20
- FWCI
- 10.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.