The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A highly sensitive acidic pH fluorescent probe and its application to HepG2 cells
Abstract
A novel acidic fluorescent probe 1 has been designed, synthesized, characterized and evaluated in vivo as optical imaging of intracellular H(+). The design strategy for the probe is based on the change in structure between spirocyclic (non-fluorescent) and ring-open (fluorescent) forms of rhodamine dyes. The probe exhibits high sensitivity, good photostability, excellent cell membrane permeability and strong pH dependence. The pH titration indicates that the fluorescence intensity increases more than 100-fold within the pH range of 4.2-6.0 with the pK(a) value of 4.85, which is valuable for studying acidic organelles in living cells. The fluorescent imaging of HepG2 cells also demonstrates that the designed probe has great value in monitoring intracellular H(+) within living cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Xu, K., Liu, X., & Tang, B. (2007) · ChemBioChem · doi:10.1002/cbic.200600392 · Cited by 71
Self-citation
Cited by
Fluorescent Chemosensors Based on Spiroring-Opening of Xanthenes and Related Derivatives
Chen, X., Pradhan, T., Wang, F., Kim, J. S., & Yoon, J. (2012) · Chemical Reviews · doi:10.1021/cr200201z · Cited by 1,984
Synthesis and applications of Rhodamine derivatives as fluorescent probes
Beija, M., Afonso, C. A. M., & Martinho, J. M. G. (2009) · Chemical Society Reviews · doi:10.1039/b901612k · Cited by 1,463
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Sakabe, M., Asanuma, D., Kamiya, M., Iwatate, R. J., Hanaoka, K., Terai, T., Nagano, T., & Urano, Y. (2013) · Journal of the American Chemical Society · doi:10.1021/ja309688m · Cited by 262
Zhang, C., Yao, X., Wang, J., & Ma, X. (2017) · Polymer Chemistry · doi:10.1039/c7py01013c · Cited by 28
Metadata
- Authors
- Zhang, W., Tang, B., Liu, X., Liu, Y., Xu, K., Ma, J., Tong, L., & Yang, G.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 134
- Issue
- 2
- Pages
- 367-371
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W1985918508
- Cited by
- 169
- References
- 1
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A highly sensitive acidic pH fluorescent probe and its application to HepG2 cells. https://app.cochat.ai/papers/10.1039/b807581f
- The paper
- Zhang, W., Tang, B., Liu, X., Liu, Y., Xu, K., Ma, J., Tong, L., & Yang, G. (2009). A highly sensitive acidic pH fluorescent probe and its application to HepG2 cells. The Analyst. https://doi.org/10.1039/b807581f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.