The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A portable surface-enhanced Raman scattering sensor integrated with a lab-on-a-chip for field analysis
Abstract
An integrated real-time sensing system that uses a portable Raman spectrometer and a micropillar array chip has been developed for field analysis. The problem of poor detection sensitivity, caused by miniaturization in the portable Raman spectrometer, was overcome by using the surface-enhanced Raman scattering (SERS) technique. The problem of poor reproducibility in the SERS detection, caused by different particle sizes and inhomogeneous degrees of aggregation, was also overcome by using continuous flow and homogeneous mixing between the analytes and nanocolloidal silver in a micropillar array microfluidic chip. Two hazardous materials, dipicolinic acid and malachite green, were quantitatively analysed using our integrated portable Raman sensor system. The observed limit of detection was estimated to be 200 ppb and 500 ppb, respectively. Our proposed analytical method, using a micropillar array PDMS chip and a portable SERS system, offers a rapid and reproducible trace detection capability for hazardous materials in the field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wood, B. R., Heraud, P., Stojkovic, S., Morrison, D., Beardall, J., & McNaughton, D. (2005) · Analytical Chemistry · doi:10.1021/ac050281z · Cited by 135
Cited by
Surface-enhanced Raman spectroscopy (SERS): progress and trends
Cialla, D., März, A., Böhme, R., Theil, F., Weber, K., Schmitt, M., & Popp, J. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5631-x · Cited by 931
Recent progress in SERS biosensing
Bantz, K. C., Meyer, A. F., Wittenberg, N. J., Im, H., Kurtuluş, Ö., Lee, S. H., Lindquist, N. C., Oh, S.-H., & Haynes, C. L. (2011) · Physical Chemistry Chemical Physics · doi:10.1039/c0cp01841d · Cited by 620
Surface-Enhanced Raman Spectroscopy (SERS) for Environmental Analyses
Halvorson, R. A., & Vikesland, P. J. (2010) · Environmental Science & Technology · doi:10.1021/es101228z · Cited by 484
Latest Developments in Micro Total Analysis Systems
Arora, A., Simone, G., Salieb-Beugelaar, G. B., Kim, J. T., & Manz, A. (2010) · Analytical Chemistry · doi:10.1021/ac100969k · Cited by 421
Plasmonic colorimetric and SERS sensors for environmental analysis
Wei, H., Hossein Abtahi, S. M., & Vikesland, P. J. (2015) · Environmental Science: Nano · doi:10.1039/c4en00211c · Cited by 285
Metadata
- Authors
- Quang, L. X., Lim, C., Seong, G. H., Choo, J., Do, K. J., & Yoo, S.-K.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 8
- Issue
- 12
- Pages
- 2214
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2073708689
- Cited by
- 158
- References
- 1
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A portable surface-enhanced Raman scattering sensor integrated with a lab-on-a-chip for field analysis. https://app.cochat.ai/papers/10.1039/b808835g
- The paper
- Quang, L. X., Lim, C., Seong, G. H., Choo, J., Do, K. J., & Yoo, S.-K. (2008). A portable surface-enhanced Raman scattering sensor integrated with a lab-on-a-chip for field analysis. Lab on a Chip. https://doi.org/10.1039/b808835g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.