Cell culture chips for simultaneous application of topographical and electrical cues enhance phenotype of cardiomyocytes
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In vivo, cardiomyocytes are exposed to multiple biochemical and physical cues including topographical and electrical cues. During prolonged in vitro cultivation in standard tissue culture set-ups, cardiomyocytes are known to de-differentiate due to the lack of appropriate micro-environmental cues. Most currently available cell culture systems provide only a single biophysical cue, thus development of advanced cell cultivation systems incorporating multiple cues is urgently needed. We report here the development of a microfabricated system, incorporating topographical and electrical cues on a single chip, which enables cultivation of differentiated cardiomyocytes. The cell culture chips were created by hot embossing of polystyrene, to create microgrooves and microridges of precisely defined depth, width and periodicity. Substrates consisting of 0.5 microm-wide grooves and 0.5 microm-wide ridges (1 microm period) and those consisting of 3 microm-wide grooves and 1 microm-wide ridges (4 microm period) were investigated, with smooth surfaces used as controls. The depth of the microgrooves was 400 nm. The two gold electrodes were electrodeposited 1 cm apart such that the microgrooves in-between were oriented either parallel or perpendicular to the electrodes, enabling studies of interaction between topographical and electrical cues. Neonatal rat cardiomyocytes cultivated on microgrooved substrates for 7 days were elongated and aligned along the microgrooves forming a well developed contractile apparatus, as evidenced by sarcomeric alpha-actinin staining, with a more pronounced effect on substrates with 1 microm compared to 4 microm periodicity. Importantly, simultaneous application of biphasic electrical pulses and topographical cues resulted in gap junctions confined to the cell-cell end junctions rather than the punctate distribution found in neonatal cells. Electrical field stimulation further enhanced cardiomyocyte elongation when microgrooves were oriented parallel to the electric field. Due to the compatibility of the described cell culture chips with fluorescence and optical microscopy as well as the ability to independently control field stimulation parameters, biochemical and topographical cues on each chip, this system may in the future become a useful tool in drug development and maturation of cardiomyocytes derived from stem cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue Engineering of a Differentiated Cardiac Muscle Construct
Zimmermann, W.-H., Schneiderbanger, K., Schubert, P., Didié, M., Münzel, F., Heubach, J. F., Kostin, S., Neuhuber, W. L., & Eschenhagen, T. (2002) · Circulation Research · doi:10.1161/hh0202.103644 · Cited by 917
Topographical control of cell behaviour: II. multiple grooved substrata
Clark, P., Connolly, P., Curtis, A. S. G., Dow, J. A. T., & Wilkinson, C. D. W. (1990) · Development · doi:10.1242/dev.108.4.635 · Cited by 682
Cited by
Engineering Adolescence: Maturation of Human Pluripotent Stem Cell–Derived Cardiomyocytes
Yang, X., Pabon, L., & Murry, C. E. (2014) · Circulation Research · doi:10.1161/circresaha.114.300558 · Cited by 939
“For instance, cultivation of the cells on patterned substrates provides topographical cues that significantly enhance cell alignment.(86,87) McDevitt et al(88) seeded NRVM onto microcontact-printed laminin lanes 5 to 50 μm wide.”
BackgroundCardiomyocyte Maturation: New Phase in Development
Guo, Y., & Pu, W. T. (2020) · Circulation Research · doi:10.1161/circresaha.119.315862 · Cited by 653
Engineering microscale topographies to control the cell–substrate interface
Nikkhah, M., Edalat, F., Manoucheri, S., & Khademhosseini, A. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.03.079 · Cited by 640
Matrix nanotopography as a regulator of cell function
Kim, D.-H., Provenzano, P. P., Smith, C. L., & Levchenko, A. (2012) · Journal of Cell Biology · doi:10.1083/jcb.201108062 · Cited by 575
Small molecule absorption by PDMS in the context of drug response bioassays
van Meer, B. J., de Vries, H., Firth, K. S. A., van Weerd, J., Tertoolen, L. G. J., Karperien, H. B. J., Jonkheijm, P., Denning, C., IJzerman, A. P., & Mummery, C. L. (2017) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2016.11.062 · Cited by 502
“Uncoated PDMS is biocompatible, but cells only attach following surface treatments such as the exposure to an oxygen plasma or ultra violet light [30,31].”
BackgroundOrgan-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Self-citationElectrical and mechanical stimulation of cardiac cells and tissue constructs
Stoppel, W. L., Kaplan, D. L., & Black, L. D. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.07.009 · Cited by 289
Evolution of Biochip Technology: A Review from Lab-on-a-Chip to Organ-on-a-Chip
Azizipour, N., Avazpour, R., Rosenzweig, D. H., Sawan, M., & Ajji, A. (2020) · Micromachines · doi:10.3390/mi11060599 · Cited by 277
Mihic, A., Li, J., Miyagi, Y., Gagliardi, M., Li, S.-H., Zu, J., Weisel, R. D., Keller, G., & Li, R.-K. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2013.12.052 · Cited by 248
Maturing human pluripotent stem cell-derived cardiomyocytes in human engineered cardiac tissues
Feric, N. T., & Radisic, M. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.04.019 · Cited by 247
Self-citationCardiovascular organ-on-a-chip platforms for drug discovery and development
Ribas, J., Sadeghi, H., Manbachi, A., Leijten, J., Brinegar, K., Zhang, Y. S., Ferreira, L., & Khademhosseini, A. (2016) · Applied In Vitro Toxicology · doi:10.1089/aivt.2016.0002 · Cited by 161
“A cell culture chip to form in vitro cardiac microtissues through the application of electrical stimulation and topographical cues was created by Au and colleagues.(70) Here, neonatal rat CMs were seeded and cultured onto polystyrene cell culture chips with integrated topographical microgrooves.”
MethodChen, A., Lieu, D. K., Freschauf, L., Lew, V., Sharma, H., Wang, J., Nguyen, D., Karakikes, I., Hajjar, R. J., Gopinathan, A., et al. (2011) · Advanced Materials · doi:10.1002/adma.201103463 · Cited by 122
Metadata
- Authors
- Heidi Au, H. T., Cui, B., Chu, Z. E., Veres, T., & Radisic, M.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 9
- Issue
- 4
- Pages
- 564-575
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1978593765
- Cited by
- 135
- References
- 2
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.