The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Modular poly(ethylene glycol) ligands for biocompatible semiconductor and gold nanocrystals with extended pH and ionic stability
Abstract
We describe the design of new ligands made by coupling commercially available poly(ethylene glycol) methyl ether (mPEG, HO-PEG-OCH3) and thioctic acid (TA) via a stable amide bond to form TA-PEG-OCH3 molecules. The ligands were obtained by a simple transformation of the hydroxyl group on the mPEG into an amine group, followed by attachment of TA viaN,N′-dicyclohexylcarbodiimide (DCC) coupling. Following ring opening of the 1,2-dithiolane on the TA-PEG-OCH3 to form a dihydrolipoic acid (DHLA) group, DHLA-PEG-OCH3 was obtained. Cap exchange of nanoparticles with DHLA-PEG-OCH3 provided dispersions in buffer solutions that were stable over a broad pH range (from 3 to 13 for CdSe-ZnS QDs and 2–13 for Au nanoparticles). Using DHLA-PEG-OCH3 either neat or mixed with amine- or carboxyl-terminated ligands (DHLA-PEG-NH2 or DHLA-PEG-COOH) allowed tuning of the surface functionalities of these nanoparticles. Microinjection of the ligand-exchanged QDs into live cells indicated that the newly capped QDs were stable and well dispersed in the cell cytosol for up to 32 h following delivery. The fluorescence distribution and its evolution over time of these DHLA-PEG-OCH3-QDs indicate improved intracellular stability and reduced non-specific interactions compared to nanocrystals capped with DHLA-PEG-OH.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dabbousi, B. O., Rodriguez-Viejo, J., Mikulec, F. V., Heine, J. R., Mattoussi, H., Ober, R., Jensen, K. F., & Bawendi, M. G. (1997) · The Journal of Physical Chemistry B · doi:10.1021/jp971091y · Cited by 4,229
Self-citation
Cited by
Susumu, K., Oh, E., Delehanty, J. B., Blanco-Canosa, J. B., Johnson, B. J., Jain, V., Hervey, W. J., Algar, W. R., Boeneman, K., Dawson, P. E., et al. (2011) · Journal of the American Chemical Society · doi:10.1021/ja201919s · Cited by 293
Self-citationLiu, W., Greytak, A. B., Lee, J., Wong, C. R., Park, J., Marshall, L. F., Jiang, W., Curtin, P. N., Ting, A. Y., Nocera, D. G., et al. (2010) · Journal of the American Chemical Society · doi:10.1021/ja908137d · Cited by 278
Nag, O. K., Stewart, M. H., Deschamps, J. R., Susumu, K., Oh, E., Tsytsarev, V., Tang, Q., Efros, A. L., Vaxenburg, R., Black, B. J., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b00954 · Cited by 80
Self-citationPrabhu, S., Goda, J. S., Mutalik, S., Mohanty, B. S., Chaudhari, P., Rai, S., Udupa, N., & Rao, B. S. S. (2017) · Nanoscale · doi:10.1039/c7nr00305f · Cited by 54
Metadata
- Authors
- Mei, B. C., Susumu, K., Medintz, I. L., Delehanty, J. B., Mountziaris, T. J., & Mattoussi, H.
- Venue
- Journal of Materials Chemistry
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 18
- Issue
- 41
- Pages
- 4949
- ISSN
- 0959-9428 (ISSN-L)
- 1364-5501
- OpenAlex
- W2011278414
- Cited by
- 210
- References
- 1
- FWCI
- 8.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.