Rapid generation of spatially and temporally controllable long-range concentration gradients in a microfluidic device
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The ability to rapidly generate concentration gradients of diffusible molecules has important applications in many chemical and biological studies. Here we established spatially and temporally controllable concentration gradients of molecules (i.e. proteins or toxins) in a portable microfluidic device in an easy and rapid manner. The formation of the concentration gradients was initiated by a passive-pump-induced forward flow and further optimized during an evaporation-induced backward flow. The centimeter-long gradients along the microfluidic channel were shown to be spatially and temporally controlled by the backward flow. The gradient profile was stabilized by stopping the flow. Computational simulations of this dynamic process illustrated the combined effects of convection and diffusion on the gradient generation, and fit well with the experimental data. To demonstrate the applications of this methodology, a stabilized concentration gradient of a cardiac toxin, alpha-cypermethrin, along the microchannel was used to test the response of HL-1 cardiac cells in the micro-device, which correlated with toxicity data obtained from multi-well plates. The approach presented here may be useful for many biological and chemical processes that require rapid generation of long-range gradients in a portable microfluidic device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Claycomb, W. C., Lanson, N. A., Stallworth, B. S., Egeland, D. B., Delcarpio, J. B., Bahinski, A., & Izzo, N. J. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.6.2979 · Cited by 1,546
Biomolecular gradients in cell culture systems
Keenan, T. M., & Folch, A. (2008) · Lab Chip · doi:10.1039/b711887b · Cited by 596
Permeation-driven flow in poly(dimethylsiloxane) microfluidic devices.
Randall, G. C., & Doyle, P. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503287102 · Cited by 220
Berthier, E., Warrick, J., Yu, H., & Beebe, D. J. (2008) · Lab on a Chip · doi:10.1039/b717422e · Cited by 114
Cited by
Fundamentals of microfluidic cell culture in controlled microenvironments
Young, E. W. K., & Beebe, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b909900j · Cited by 615
Biomimetic gradient hydrogels for tissue engineering
Sant, S., Hancock, M. J., Donnelly, J. P., Iyer, D., & Khademhosseini, A. (2010) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.20411 · Cited by 253
Self-citationChang, C.-W., Cheng, Y.-J., Tu, M., Chen, Y.-H., Peng, C.-C., Liao, W.-H., & Tung, Y.-C. (2014) · Lab Chip · doi:10.1039/c4lc00732h · Cited by 154
In vitro metabolic zonation through oxygen gradient on a chip
Tonon, F., Giobbe, G. G., Zambon, A., Luni, C., Gagliano, O., Floreani, A., Grassi, G., & Elvassore, N. (2019) · Scientific Reports · doi:10.1038/s41598-019-49412-6 · Cited by 76
Zhao, H., Li, X., Zhao, S., Zeng, Y., Zhao, L., Ding, H., Sun, W., & Du, Y. (2014) · Biofabrication · doi:10.1088/1758-5082/6/4/045009 · Cited by 54
Self-citation
Metadata
- Authors
- Du, Y., Shim, J., Vidula, M., Hancock, M. J., Lo, E., Chung, B. G., T. Borenstein, J., Khabiry, M., M. Cropek, D., & Khademhosseini, A.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 9
- Issue
- 6
- Pages
- 761-767
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2165173713
- Cited by
- 89
- References
- 4
- FWCI
- 6.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid generation of spatially and temporally controllable long-range concentration gradients in a microfluidic device. https://app.cochat.ai/papers/10.1039/b815990d
- The paper
- Du, Y., Shim, J., Vidula, M., Hancock, M. J., Lo, E., Chung, B. G., T. Borenstein, J., Khabiry, M., M. Cropek, D., & Khademhosseini, A. (2009). Rapid generation of spatially and temporally controllable long-range concentration gradients in a microfluidic device. Lab Chip. https://doi.org/10.1039/b815990d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.