CoChat

Fine temporal control of the medium gas content and acidity and on-chip generation of series of oxygen concentrations for cell cultures

Polinkovsky, Mark, Gutierrez, Edgar, Levchenko, Andre, Groisman, Alex · 2009 · Lab on a Chip
Cited by 136

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

We describe the design, operation, and applications of two microfluidic devices that generate series of concentrations of oxygen, [O(2)], by on-chip gas mixing. Both devices are made of polydimethylsiloxane (PDMS) and have two layers of channels, the flow layer and the gas layer. By using in-situ measurements of [O(2)] with an oxygen-sensitive fluorescent dye, we show that gas diffusion through PDMS leads to equilibration of [O(2)] in an aqueous solution in the flow layer with [O(2)] in a gas injected into the gas layer on a time scale of approximately 1 sec. Injection of carbon dioxide into the gas layer causes the pH in the flow layer to drop within approximately 0.5 sec. Gas-mixing channel networks of both devices generate series of 9 gas mixtures with different [O(2)] from two gases fed to the inlets, thus creating regions with 9 different [O(2)] in the flow layer. The first device generates nitrogen-oxygen mixtures with [O(2)] varying linearly between 0 and 100%. The second device generates nitrogen-air mixtures with [O(2)] varying exponentially between 0 and 20.9%. The flow layers of the devices are designed for culturing bacteria in semi-permeable microchambers, and the second device is used to measure growth curves of E. coli colonies at 9 different [O(2)] in a single experiment. The cell division rates at [O(2)] of 0, 0.2, and 0.5% are found to be significantly different, further validating the capacity of the device to set [O(2)] in the flow layer with high precision and resolution. The degree of control of [O(2)] achieved in the devices and the robustness with respect to oxygen consumption due to respiration would be difficult to match in a traditional large-scale culture. The proposed devices and technology can be used in research on bacteria and yeast under microaerobic conditions and on mammalian cells under hypoxia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/b816191g

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 136

Metadata

Authors
Polinkovsky, M., Gutierrez, E., Levchenko, A., & Groisman, A.
Venue
Lab on a Chip
Published
2009
Volume
9
Issue
8
Pages
1073
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W1970550910
Cited by
136
References
4
FWCI
6.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.