Abstract

Cortisol detection in saliva is of great interest for the diagnosis of various disease states and the monitoring of stress in humans. Currently, measurements are performed predominantly by radioimmunoassay (RIA) which is expensive, labour intensive, uses hazardous radioisotopes and involves extensive delays in obtaining results. A rationally designed cortisol-linker conjugate allowing high assay sensitivity was employed as a coating antigen in a microfluidic surface plasmon resonance (SPR) biosensor immunoassay for the ultrasensitive and rapid detection of salivary cortisol. Detection of cortisol is by competitive immunoassay using a secondary antibody for signal enhancement. The method requires no chemical extraction or complex sample pre-treatment despite high saliva viscosity. The cortisol assay was optimized for maximum sensitivity in buffer before being adapted for the salivary matrix, where it showed a limit of detection of 49 pg/mL. The results showed good correlation to RIA (r = 0.94). The biosensor assays showed an inter-assay coefficient of variation (CV) of 13.5% and recoveries close to 100%. The covalently immobilized sensor surface provided stable responses for more than 140 binding and regeneration cycles, enabling re-use. Cortisol in saliva was detected across the physiologically relevant range using the SPR immunobiosensor by employing a rationally designed assay format including signal enhancement for maximum sensitivity. The system can handle saliva matrix effects by use of chemical treatment during the assay to reduce non-specific binding to sensor surfaces. This sensor system provides an automated, high sensitivity analytical tool capable of yielding results in approximately 15 min. This biosensor could potentially be used for active stress-monitoring and in the diagnosis of disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/b817083p

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 79

Metadata

Authors
Mitchell, J. S., Lowe, T. E., & Ingram, J. R.
Venue
The Analyst
Published
2009
Volume
134
Issue
2
Pages
380-386
ISSN
  • 0003-2654 (ISSN-L)
  • 1364-5528
OpenAlex
W2126139159
Cited by
79
References
5
FWCI
1.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rapid ultrasensitive measurement of salivary cortisol using nano-linker chemistry coupled with surface plasmon resonance detection. https://app.cochat.ai/papers/10.1039/b817083p
The paper
Mitchell, J. S., Lowe, T. E., & Ingram, J. R. (2009). Rapid ultrasensitive measurement of salivary cortisol using nano-linker chemistry coupled with surface plasmon resonance detection. The Analyst. https://doi.org/10.1039/b817083p

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.