The microfluidic palette: A diffusive gradient generator with spatio-temporal control
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper describes a new microfluidic device called the "microfluidic palette", capable of generating multiple spatial chemical gradients simultaneously inside a microfluidic chamber. The unique aspect of this work is that chemical gradients are generated by diffusion, without convection, and can either be held constant over long periods, or modified dynamically. We characterized a representative device with a 1.5 mm circular chamber where diffusion takes place, and three access-ports for the delivery and removal of solutes. The gradient stabilizes in approximately 15 min for small molecules and can be maintained constant indefinitely. We demonstrate overlapping gradients with different spatial location and a controlled rotation of a diffusive gradient around its centre. Finally, we demonstrate the applicability of this tool to study the chemotactic response of the bacteria P. aeruginosa to glucose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomolecular gradients in cell culture systems
Keenan, T. M., & Folch, A. (2008) · Lab Chip · doi:10.1039/b711887b · Cited by 596
Cited by
Fabrication of microfluidic devices using polydimethylsiloxane
Friend, J., & Yeo, L. (2010) · Biomicrofluidics · doi:10.1063/1.3259624 · Cited by 425
Latest Developments in Micro Total Analysis Systems
Arora, A., Simone, G., Salieb-Beugelaar, G. B., Kim, J. T., & Manz, A. (2010) · Analytical Chemistry · doi:10.1021/ac100969k · Cited by 421
Biological applications of microfluidic gradient devices
Kim, S., Kim, H. J., & Jeon, N. L. (2010) · Integrative Biology · doi:10.1039/c0ib00055h · Cited by 366
Biomimetic gradient hydrogels for tissue engineering
Sant, S., Hancock, M. J., Donnelly, J. P., Iyer, D., & Khademhosseini, A. (2010) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.20411 · Cited by 253
Concentration gradient generation methods based on microfluidic systems
Wang, X., Liu, Z., & Pang, Y. (2017) · RSC Advances · doi:10.1039/c7ra04494a · Cited by 219
Simultaneous or Sequential Orthogonal Gradient Formation in a 3D Cell Culture Microfluidic Platform
Uzel, S. G. M., Amadi, O. C., Pearl, T. M., Lee, R. T., So, P. T. C., & Kamm, R. D. (2016) · Small · doi:10.1002/smll.201501905 · Cited by 100
A convection-driven long-range linear gradient generator with dynamic control
Wang, H., Chen, C.-H., Xiang, Z., Wang, M., & Lee, C. (2015) · Lab on a Chip · doi:10.1039/c4lc01451k · Cited by 40
Metadata
- Authors
- Atencia, J., Morrow, J., & Locascio, L. E.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 9
- Issue
- 18
- Pages
- 2707
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2154543102
- Cited by
- 153
- References
- 1
- FWCI
- 7.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.