Microchemical systems for continuous-flow synthesis
The DOI matches its Crossref record; 125 of the 125 references it cites were found in a registry or an index.
Abstract
Microchemical systems have evolved rapidly over the last decade with extensive chemistry applications. Such systems enable discovery and development of synthetic routes while simultaneously providing increased understanding of underlying pathways and kinetics. We review basic trends and aspects of microsystems as they relate to continuous-flow microchemical synthesis. Key literature reviews are summarized and principles governing different microchemical operations discussed. Current trends and limitations of microfabrication, micromixing, chemical synthesis in microreactors, continuous-flow separations, multi-step synthesis, and integration of analytics are delineated. We conclude by summarizing the major challenges and outlook related to these topics.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Xia, Y., & Whitesides, G. M. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.153 · Cited by 4,611
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Rational Development of Practical Catalysts for Aromatic Carbon−Nitrogen Bond Formation
Wolfe, J. P., Wagaw, S., Marcoux, J.-F., & Buchwald, S. L. (1998) · Accounts of Chemical Research · doi:10.1021/ar9600650 · Cited by 1,791
Continuous inertial focusing, ordering, and separation of particles in microchannels
Di Carlo, D., Irimia, D., Tompkins, R. G., & Toner, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704958104 · Cited by 1,708
Nguyen, N.-T., & Wu, Z. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/2/r01 · Cited by 1,652
Control and detection of chemical reactions in microfluidic systems
deMello, A. J. (2006) · Nature · doi:10.1038/nature05062 · Cited by 1,495
Micromixers—a review on passive and active mixing principles
Hessel, V., Löwe, H., & Schönfeld, F. (2005) · Chemical Engineering Science · doi:10.1016/j.ces.2004.11.033 · Cited by 1,479
Chemistry in Microstructured Reactors
Jähnisch, K., Hessel, V., Löwe, H., & Baerns, M. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200300577 · Cited by 1,286
Research works printed but not linked: 8
- Chevalier, 2008, Chim. Oggi-Chem. Today, 26, 6
- Kikutani, 2003, Lab Chip, 3, 51
- Zhang, 2006, Chim. Oggi-Chem. Today, 24, 43
- Hessel, 2006, Abstr. Pap. Am. Chem. Soc., 231, 312
- Fukuyama, 2008, Synlett, 151
- Baxendale, 2006, Ernst Schering Found Symp. Proc., 151
- Mennecke, 2008, Synthesis, 1589
- Baxendale, 2006, Synlett, 427
Cited by
Items 501–512 of 512
Real-time optical spectroscopy for in situ single-droplet analysis
Pandillapally, R., Pillanagrovi, J., Dutta‐Gupta, S., & Duraiswamy, S. (2026) · Nanoscale Advances · doi:10.1039/d5na01087j
Hellé, G. (2014) · theses.fr (ABES) · doi:10.70675/644c342az6221z4678zae1eza578647fa01c · Cited by 3
Green and sustainable approach to process intensification in synthesis of sugar esters: a review
Gurudasani, V. D., & Goswami, A. K. (2026) · Chemical Papers · doi:10.1007/s11696-026-04826-1
Flow Chemistry for Safer and More Efficient Diazotization: Recent Advances and Future Prospects
Zhou, C., Wang, B., Zhou, X., Liang, X., Zhou, H., Liu, F., & Su, W. (2026) · Pharmaceutical Fronts · doi:10.1055/a-2842-5265
Rathore, R. (2026) · TMP Universal Journal of Advances in Pharmaceutical sciences · doi:10.69557/t1fd3z14
Macro-microreactor Based Flow PolymerizationsPreprint
Li, J., Zhao, S., Pan, G., Huang, J., Guo, K., Hu, X., Lü, Y., & Zhu, N. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.7499286
Continuous-Flow Synthesis of Diisopropyl Xanthogen Disulfide with a Coiled Microreactor
Qin, W.-J., Yang, H., Li, X., & Wang, X. (2026) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.6c02769
Metadata
- Authors
- Hartman, R. L., & Jensen, K. F.
- Affiliations
- Massachusetts Institute of Technology (US)
- Corresponding author
- Jensen, Klavs F.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 9
- Issue
- 17
- Pages
- 2495
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2071785669
- Cited by
- 508
- References
- 125
- Citations by year
- 2026: 10 · 2025: 13 · 2024: 11 · 2023: 11 · 2022: 15 · 2021: 8 · 2020: 26 · 2019: 33 · 2018: 28 · 2017: 34 · 2016: 46 · 2015: 37 · 2014: 41 · 2013: 41 · 2012: 58
- FWCI
- 30.44
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemistry › Organic Chemistry › Microwave-Assisted Synthesis and Applications
- Keywords
- microchemical systems, flow chemistry, microreactors, microfabrication, micromixing, continuous flow separation, multistep synthesis, reaction kinetics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.