The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Lensfree microscopy on a cellphone
Open accessAbstract
We demonstrate lensfree digital microscopy on a cellphone. This compact and light-weight holographic microscope installed on a cellphone does not utilize any lenses, lasers or other bulky optical components and it may offer a cost-effective tool for telemedicine applications to address various global health challenges. Weighing approximately 38 grams (<1.4 ounces), this lensfree imaging platform can be mechanically attached to the camera unit of a cellphone where the samples are loaded from the side, and are vertically illuminated by a simple light-emitting diode (LED). This incoherent LED light is then scattered from each micro-object to coherently interfere with the background light, creating the lensfree hologram of each object on the detector array of the cellphone. These holographic signatures captured by the cellphone permit reconstruction of microscopic images of the objects through rapid digital processing. We report the performance of this lensfree cellphone microscope by imaging various sized micro-particles, as well as red blood cells, white blood cells, platelets and a waterborne parasite (Giardia lamblia).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Fourier optics
Goodman, J. W. (1968) · Cited by 10,608
Reconstruction of an object from the modulus of its Fourier transform
Fienup, J. R. (1978) · Optics Letters · doi:10.1364/ol.3.000027 · Cited by 1,836
Mobile Phone Based Clinical Microscopy for Global Health Applications
Breslauer, D. N., Maamari, R. N., Switz, N. A., Lam, W. A., & Fletcher, D. A. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006320 · Cited by 694
Digital in-line holography for biological applications
Xu, W., Jericho, M. H., Meinertzhagen, I. A., & Kreuzer, H. J. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.191361398 · Cited by 576
Lensfree holographic imaging for on-chip cytometry and diagnostics
Seo, S., Su, T., Tseng, D. K., Erlinger, A., & Özcan, A. (2008) · Lab on a Chip · doi:10.1039/b813943a · Cited by 273
Self-citationOn-chip differential interference contrast microscopy using lensless digital holography
Oh, C., Isikman, S. O., Khademhosseinieh, B., & Özcan, A. (2010) · Optics Express · doi:10.1364/oe.18.004717 · Cited by 85
Self-citationFife, K. G., Gamal, A. E., & Wong, H. ‐. P. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2006457 · Cited by 27
Cited by
Emerging Technologies for Next-Generation Point-of-Care Testing
Vashist, S. K., Luppa, P. B., Yeo, L. Y., Ozcan, A., & Luong, J. H. T. (2015) · Trends in Biotechnology · doi:10.1016/j.tibtech.2015.09.001 · Cited by 705
Self-citationThe Smartphone in Medicine: A Review of Current and Potential Use Among Physicians and Students
Ozdalga, E., Ozdalga, A., & Ahuja, N. (2012) · Journal of Medical Internet Research · doi:10.2196/jmir.1994 · Cited by 654
“Engineers have created various microscopes that attach to smartphones, providing a cost-effective and mobile way to bring more technology to poor and rural regions [50-52].”
BackgroundBiosensors and bioelectronics on smartphone for portable biochemical detection
Zhang, D., & Liu, Q. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.037 · Cited by 647
Transport of intensity equation: a tutorial
Zuo, C., Li, J., Sun, J., Fan, Y., Zhang, J., Lu, L., Zhang, R., Wang, B., Huang, L., & Chen, Q. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106187 · Cited by 581
Smartphone-based biosensors: A critical review and perspectives
Roda, A., Michelini, E., Zangheri, M., Di Fusco, M., Calabria, D., & Simoni, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.10.019 · Cited by 520
Lee, K., Kim, K., Jung, J., Heo, J., Cho, S., Lee, S., Chang, G., Jo, Y., Park, H., & Park, Y. (2013) · Sensors · doi:10.3390/s130404170 · Cited by 510
An Optofluidic Nanoplasmonic Biosensor for Direct Detection of Live Viruses from Biological Media
Yanik, A. A., Huang, M., Kamohara, O., Artar, A., Geisbert, T. W., Connor, J. H., & Altug, H. (2010) · Nano Letters · doi:10.1021/nl103025u · Cited by 454
Fluorescent Imaging of Single Nanoparticles and Viruses on a Smart Phone
Wei, Q., Qi, H., Luo, W., Tseng, D., Ki, S. J., Wan, Z., Göröcs, Z., Bentolila, L. A., Wu, T.-T., Sun, R., et al. (2013) · ACS Nano · doi:10.1021/nn4037706 · Cited by 452
Self-citationIntegrated rapid-diagnostic-test reader platform on a cellphone
Mudanyali, O., Dimitrov, S., Sikora, U., Padmanabhan, S., Navruz, I., & Ozcan, A. (2012) · Lab on a Chip · doi:10.1039/c2lc40235a · Cited by 426
Self-citationDiffraction phase microscopy: principles and applications in materials and life sciences
Bhaduri, B., Edwards, C., Pham, H., Zhou, R., Nguyen, T. H., Goddard, L. L., & Popescu, G. (2014) · Advances in Optics and Photonics · doi:10.1364/aop.6.000057 · Cited by 425
Detection and Spatial Mapping of Mercury Contamination in Water Samples Using a Smart-Phone
Wei, Q., Nagi, R., Sadeghi, K., Feng, S., Yan, E., Ki, S. J., Caire, R., Tseng, D., & Ozcan, A. (2014) · ACS Nano · doi:10.1021/nn406571t · Cited by 400
Self-citationOptofluidic Fluorescent Imaging Cytometry on a Cell Phone
Zhu, H., Mavandadi, S., Coskun, A. F., Yaglidere, O., & Ozcan, A. (2011) · Analytical Chemistry · doi:10.1021/ac201587a · Cited by 390
Self-citationMobile phones democratize and cultivate next-generation imaging, diagnostics and measurement tools
Ozcan, A. (2014) · Lab Chip · doi:10.1039/c4lc00010b · Cited by 364
Self-citationOptical imaging techniques for point-of-care diagnostics
Zhu, H., Isikman, S. O., Mudanyali, O., Greenbaum, A., & Ozcan, A. (2013) · Lab Chip · doi:10.1039/c2lc40864c · Cited by 364
Self-citationHandheld high-throughput plasmonic biosensor using computational on-chip imaging
Cetin, A. E., Coskun, A. F., Galarreta, B. C., Huang, M., Herman, D., Ozcan, A., & Altug, H. (2014) · Light: Science & Applications · doi:10.1038/lsa.2014.3 · Cited by 354
Self-citationOzcan, A., & McLeod, E. (2016) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-092515-010849 · Cited by 352
Self-citationNanochromatography Driven by the Coffee Ring Effect
Wong, T.-S., Chen, T.-H., Shen, X., & Ho, C.-M. (2011) · Analytical Chemistry · doi:10.1021/ac102963x · Cited by 350
Cell-Phone-Based Platform for Biomedical Device Development and Education Applications
Smith, Z. J., Chu, K., Espenson, A. R., Rahimzadeh, M., Gryshuk, A., Molinaro, M., Dwyre, D. M., Lane, S., Matthews, D., & Wachsmann-Hogiu, S. (2011) · PLoS ONE · doi:10.1371/journal.pone.0017150 · Cited by 339
Cost-effective and compact wide-field fluorescent imaging on a cell-phone
Zhu, H., Yaglidere, O., Su, T.-W., Tseng, D., & Ozcan, A. (2011) · Lab Chip · doi:10.1039/c0lc00358a · Cited by 330
Self-citationPortable biosensing devices for point-of-care diagnostics: Recent developments and applications
Zarei, M. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.04.001 · Cited by 326
Label-free biodetection using a smartphone
Gallegos, D., Long, K. D., Yu, H., Clark, P. P., Lin, Y., George, S., Nath, P., & Cunningham, B. T. (2013) · Lab on a Chip · doi:10.1039/c3lc40991k · Cited by 312
Cellphone-based devices for bioanalytical sciences
Vashist, S. K., Mudanyali, O., Schneider, E. M., Zengerle, R., & Ozcan, A. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7473-1 · Cited by 305
Self-citationSmartphone-based analytical biosensors
Huang, X., Xu, D., Chen, J., Liu, J., Li, Y., Song, J., Ma, X., & Guo, J. (2018) · The Analyst · doi:10.1039/c8an01269e · Cited by 305
A smartphone-based diagnostic platform for rapid detection of Zika, chikungunya, and dengue viruses
Priye, A., Bird, S. W., Light, Y. K., Ball, C. S., Negrete, O. A., & Meagher, R. J. (2017) · Scientific Reports · doi:10.1038/srep44778 · Cited by 300
Mait, J. N., Euliss, G. W., & Athale, R. A. (2018) · Advances in Optics and Photonics · doi:10.1364/aop.10.000409 · Cited by 289
Holographic pixel super-resolution in portable lensless on-chip microscopy using a fiber-optic array
Bishara, W., Sikora, U., Mudanyali, O., Su, T.-W., Yaglidere, O., Luckhart, S., & Ozcan, A. (2011) · Lab on a Chip · doi:10.1039/c0lc00684j · Cited by 288
Self-citationA smartphone algorithm with inter-phone repeatability for the analysis of colorimetric tests
Yetisen, A. K., Martinez-Hurtado, J. L., Garcia-Melendrez, A., da Cruz Vasconcellos, F., & Lowe, C. R. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.01.077 · Cited by 285
Quantum dot enabled detection of Escherichia coli using a cell-phone
Zhu, H., Sikora, U., & Ozcan, A. (2012) · The Analyst · doi:10.1039/c2an35071h · Cited by 277
Self-citationQuantitative phase imaging based on holography: trends and new perspectives
Huang, Z., & Cao, L. (2024) · Light: Science & Applications · doi:10.1038/s41377-024-01453-x · Cited by 277
Cost-effective and rapid blood analysis on a cell-phone
Zhu, H., Sencan, I., Wong, J., Dimitrov, S., Tseng, D., Nagashima, K., & Ozcan, A. (2013) · Lab on a Chip · doi:10.1039/c3lc41408f · Cited by 274
Self-citationMobile phone-based biosensing: An emerging “diagnostic and communication” technology
Quesada-González, D., & Merkoçi, A. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.10.062 · Cited by 272
Wu, Y., & Ozcan, A. (2018) · Methods · doi:10.1016/j.ymeth.2017.08.013 · Cited by 260
Self-citationWang, B., Li, Y., Zhou, M., Han, Y., Zhang, M., Gao, Z., Liu, Z., Chen, P., Du, W., Zhang, X., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-36017-x · Cited by 259
Rapid electrochemical detection on a mobile phone
Lillehoj, P. B., Huang, M.-C., Truong, N., & Ho, C.-M. (2013) · Lab on a Chip · doi:10.1039/c3lc50306b · Cited by 259
Quantitative Imaging with a Mobile Phone Microscope
Skandarajah, A., Reber, C. D., Switz, N. A., & Fletcher, D. A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0096906 · Cited by 196
Tuijn, C. J., Hoefman, B. J., van Beijma, H., Oskam, L., & Chevrollier, N. (2011) · PLoS ONE · doi:10.1371/journal.pone.0028348 · Cited by 60
Metadata
- Authors
- Tseng, D., Mudanyali, O., Oztoprak, C., Isikman, S. O., Sencan, I., Yaglidere, O., & Ozcan, A.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 10
- Issue
- 14
- Pages
- 1787
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2111765476
- Cited by
- 480
- References
- 7
- FWCI
- 20.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.