Deformability based cell margination—A simple microfluidic design for malaria-infected erythrocyte separation

Hou, Han Wei, Bhagat, Ali Asgar S., Lin Chong, Alvin Guo, Mao, Pan, Wei Tan, Kevin Shyong, Han, Jongyoon, Lim, Chwee Teck·2010·Lab on a Chip

Abstract

In blood vessels with luminal diameter less than 300 µm, red blood cells (RBCs) which are smaller in size and more deformable than leukocytes, migrate to the axial centre of the vessel due to flow velocity gradient within the vessels. This phenomenon displaces the leukocytes to the vessel wall and is aptly termed as margination. Here, we demonstrate using microfluidics that stiffer malaria-infected RBCs (iRBCs) behave similar to leukocytes and undergo margination towards the sidewalls. This provides better understanding of the hemodynamic effects of iRBCs in microcirculation and its contribution to pathophysiological outcome relating to cytoadherence to endothelium. In this work, cell margination is mimicked for the separation of iRBCs from whole blood based on their reduced deformability. The malaria infected sample was tested in a simple long straight channel microfluidic device fabricated in polydimethylsiloxane. In this microchannel, cell margination was directed along the channel width with the iRBCs aligning near each sidewall and then subsequently removed using a 3-outlet system, thus achieving separation. Tests were conducted using ring stage and late trophozoite/schizont stage iRBCs. Device performance was quantified by analyzing the distribution of these iRBCs across the microchannel width at the outlet and also conducting flow cytometry analysis. Results indicate recovery of approximately 75% for early stage iRBCs and >90% for late stage iRBCs at the side outlets. The simple and passive system operation makes this technique ideal for on-site iRBCs enrichment in resource-limited settings, and can be applied to other blood cell diseases, e.g. sickle cell anemia and leukemia, characterized by changes in cell stiffness.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c003873c

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 40 references

Cited by

See all 300

Metadata

Authors
Hou, H. W., Bhagat, A. A. S., Lin Chong, A. G., Mao, P., Wei Tan, K. S., Han, J., & Lim, C. T.
Venue
Lab on a Chip
Published
2010
Volume
10
Issue
19
Pages
2605
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2079832375
Cited by
300
References
40
FWCI
13.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Deformability based cell margination—A simple microfluidic design for malaria-infected erythrocyte separation. https://app.cochat.ai/papers/10.1039/c003873c
The paper
Hou, H. W., Bhagat, A. A. S., Lin Chong, A. G., Mao, P., Wei Tan, K. S., Han, J., & Lim, C. T. (2010). Deformability based cell margination—A simple microfluidic design for malaria-infected erythrocyte separation. Lab on a Chip. https://doi.org/10.1039/c003873c

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.