The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Fabrication of circular microfluidic channels by combining mechanical micromilling and soft lithography
Abstract
The fabrication of microfluidic channels with complex three-dimensional (3D) geometries presents a major challenge to the field of microfluidics, because conventional lithography methods are mainly limited to rectangular cross-sections. In this paper, we demonstrate the use of mechanical micromachining to fabricate microfluidic channels with complex cross-sectional geometries. Micro-scale milling tools are first used to fabricate semi-circular patterns on planar metallic surfaces to create a master mold. The micromilled pattern is then transferred to polydimethylsiloxane (PDMS) through a two-step reverse molding process. Using these semi-circular PDMS channels, circular cross-sectioned microchannels are created by aligning and adhering two channels face-to-face. Straight and serpentine-shaped microchannels were fabricated, and the channel geometry and precision of the metallic master and PDMS molds were assessed through scanning electron microscopy and non-contact profilometry. Channel functionality was tested by perfusion of liquid through the channels. This work demonstrates that micromachining enabled soft lithography is capable of fabricating non-rectangular cross-section channels for microfluidic applications. We believe that this approach will be important for many fields from biomimetics and vascular engineering to microfabrication and microreactor technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Cited by
Micromilling: a method for ultra-rapid prototyping of plastic microfluidic devices
Guckenberger, D. J., de Groot, T. E., Wan, A. M. D., Beebe, D. J., & Young, E. W. K. (2015) · Lab on a Chip · doi:10.1039/c5lc00234f · Cited by 513
Production of uniform droplets using membrane, microchannel and microfluidic emulsification devices
Vladisavljević, G. T., Kobayashi, I., & Nakajima, M. (2012) · Microfluidics and Nanofluidics · doi:10.1007/s10404-012-0948-0 · Cited by 374
Biomedical microfluidic devices by using low-cost fabrication techniques: A review
Faustino, V., Catarino, S. O., Lima, R., & Minas, G. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.11.031 · Cited by 338
Industrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
A review on microreactors: Reactor fabrication, design, and cutting-edge applications
Suryawanshi, P. L., Gumfekar, S. P., Bhanvase, B. A., Sonawane, S. H., & Pimplapure, M. S. (2018) · Chemical Engineering Science · doi:10.1016/j.ces.2018.03.026 · Cited by 305
Metadata
- Authors
- Wilson, M. E., Kota, N., Kim, Y., Wang, Y., Stolz, D. B., LeDuc, P. R., & Ozdoganlar, O. B.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 11
- Issue
- 8
- Pages
- 1550
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2120027261
- Cited by
- 158
- References
- 1
- FWCI
- 5.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.