The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Holographic pixel super-resolution in portable lensless on-chip microscopy using a fiber-optic array
Open accessAbstract
We report a portable lensless on-chip microscope that can achieve <1 µm resolution over a wide field-of-view of ∼ 24 mm(2) without the use of any mechanical scanning. This compact on-chip microscope weighs ∼ 95 g and is based on partially coherent digital in-line holography. Multiple fiber-optic waveguides are butt-coupled to light emitting diodes, which are controlled by a low-cost micro-controller to sequentially illuminate the sample. The resulting lensfree holograms are then captured by a digital sensor-array and are rapidly processed using a pixel super-resolution algorithm to generate much higher resolution holographic images (both phase and amplitude) of the objects. This wide-field and high-resolution on-chip microscope, being compact and light-weight, would be important for global health problems such as diagnosis of infectious diseases in remote locations. Toward this end, we validate the performance of this field-portable microscope by imaging human malaria parasites (Plasmodium falciparum) in thin blood smears. Our results constitute the first-time that a lensfree on-chip microscope has successfully imaged malaria parasites.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Super-resolution image reconstruction: a technical overview
Park, S. C., Park, M. K., & Kang, M. G. (2003) · IEEE Signal Processing Magazine · doi:10.1109/msp.2003.1203207 · Cited by 3,282
Joint MAP registration and high-resolution image estimation using a sequence of undersampled images
Hardie, R. C., Barnard, K. J., & Armstrong, E. E. (1997) · IEEE Transactions on Image Processing · doi:10.1109/83.650116 · Cited by 826
Mobile Phone Based Clinical Microscopy for Global Health Applications
Breslauer, D. N., Maamari, R. N., Switz, N. A., Lam, W. A., & Fletcher, D. A. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006320 · Cited by 694
Mudanyali, O., Tseng, D., Oh, C., Isikman, S. O., Sencan, I., Bishara, W., Oztoprak, C., Seo, S., Khademhosseini, B., & Ozcan, A. (2010) · Lab on a Chip · doi:10.1039/c000453g · Cited by 488
Self-citationLensfree microscopy on a cellphone
Tseng, D., Mudanyali, O., Oztoprak, C., Isikman, S. O., Sencan, I., Yaglidere, O., & Ozcan, A. (2010) · Lab on a Chip · doi:10.1039/c003477k · Cited by 480
Self-citationLensfree on-chip microscopy over a wide field-of-view using pixel super-resolution
Bishara, W., Su, T.-W., Coskun, A. F., & Ozcan, A. (2010) · Optics Express · doi:10.1364/oe.18.011181 · Cited by 440
Self-citationHolographic opto-fluidic microscopy
Bishara, W., Zhu, H., & Özcan, A. (2010) · Optics Express · doi:10.1364/oe.18.027499 · Cited by 149
Self-citationWoods, N. A., Galatsanos, N. P., & Katsaggelos, A. K. (2005) · IEEE Transactions on Image Processing · doi:10.1109/tip.2005.860355 · Cited by 130
Goddard, G., Martin, J. C., Graves, S. W., & Kaduchak, G. (2006) · Cytometry Part A · doi:10.1002/cyto.a.20205 · Cited by 119
Portable, Battery-Operated, Low-Cost, Bright Field and Fluorescence Microscope
Miller, A. R., Davis, G. L., Oden, Z. M., Razavi, M. R., Fateh, A., Ghazanfari, M., Abdolrahimi, F., Dizaji, S. P., Sakhaie, F., Olsen, R. J., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0011890 · Cited by 97
Cited by
Smartphone-based biosensors: A critical review and perspectives
Roda, A., Michelini, E., Zangheri, M., Di Fusco, M., Calabria, D., & Simoni, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.10.019 · Cited by 520
Optical imaging techniques for point-of-care diagnostics
Zhu, H., Isikman, S. O., Mudanyali, O., Greenbaum, A., & Ozcan, A. (2013) · Lab Chip · doi:10.1039/c2lc40864c · Cited by 364
Self-citationWasisto, H. S., Prades, J. D., Gülink, J., & Waag, A. (2019) · Applied Physics Reviews · doi:10.1063/1.5096322 · Cited by 309
Cellphone-based devices for bioanalytical sciences
Vashist, S. K., Mudanyali, O., Schneider, E. M., Zengerle, R., & Ozcan, A. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7473-1 · Cited by 305
Self-citationSmartphone-based analytical biosensors
Huang, X., Xu, D., Chen, J., Liu, J., Li, Y., Song, J., Ma, X., & Guo, J. (2018) · The Analyst · doi:10.1039/c8an01269e · Cited by 305
Metadata
- Authors
- Bishara, W., Sikora, U., Mudanyali, O., Su, T.-W., Yaglidere, O., Luckhart, S., & Ozcan, A.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 11
- Issue
- 7
- Pages
- 1276
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2155521443
- Cited by
- 288
- References
- 11
- FWCI
- 11.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Holographic pixel super-resolution in portable lensless on-chip microscopy using a fiber-optic array. https://app.cochat.ai/papers/10.1039/c0lc00684j
- The paper
- Bishara, W., Sikora, U., Mudanyali, O., Su, T.-W., Yaglidere, O., Luckhart, S., & Ozcan, A. (2011). Holographic pixel super-resolution in portable lensless on-chip microscopy using a fiber-optic array. Lab on a Chip. https://doi.org/10.1039/c0lc00684j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.