The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A comprehensive review of CUPRAC methodology
Abstract
Measuring the antioxidant activity/capacity levels of food and biological fluids is carried out for the meaningful comparison of the antioxidant content of foodstuffs and for the diagnosis and treatment of oxidative stress-associated diseases in clinical biochemistry. Current literature clearly states that there is no widely adopted/accepted “total antioxidant parameter” as a nutritional index available for the labeling of food and biological fluids due to the lack of standardized quantitation methods. The “parent” CUPRAC (CUPric Reducing Antioxidant Capacity) method of antioxidant measurement, introduced by our research group to world literature, is based on the absorbance measurement of Cu(I)-neocuproine (Nc) chelate formed as a result of the redox reaction of chain-breaking antioxidants with the CUPRAC reagent, Cu(II)-Nc, where absorbance is recorded at the maximal light absorption wavelength of 450 nm; thus this is an electron-transfer (ET)-based method. From the parent CUPRAC method initially applied to food (apricot, herbal teas, wild edible plants, herby cheese etc.) and biological fluids (as hydrophilic and lipophilic antioxidants together or in separate fractions), a number of “daughter” methods have evolved, such as the simultaneous assay of both lipophilic and hydrophilic antioxidants in acetone-water as methyl-β-cyclodextrin inclusion complexes, determination of ascorbic acid alone in the presence of flavonoids (with preliminary extraction of flavonoids as their La(III)-complexes), determination of hydroxyl radical scavenging activity of both water-soluble antioxidants (using benzoate derivatives and salicylate as hydroxylation probes) and of polyphenols using catalase to stop the Fenton reaction so as to prevent redox cycling of antioxidants, measurement of Cu(II)-catalyzed hydrogen peroxide scavenging activity and of xanthine oxidase inhibition activity of polyphenols, TAC measurement of protein thiols in urea buffer, development of a CUPRAC-based antioxidant sensor on a Nafion cation-exchanger membrane, the off-line HPLC-CUPRAC assay and finally the on-line HPLC-CUPRAC assay of antioxidants with post-column detection. The current direction of CUPRAC methodology can be best described as a self-sufficient and integrated train of measurements providing a useful “antioxidant and antiradical assay package”. This review attempts to unify and summarize various methodologies of main and modified CUPRAC procedures that can normally be extracted from quite different literature sources.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Colorimetry of Total Phenolics with Phosphomolybdic-Phosphotungstic Acid Reagents
Singleton, V. L., & Rossi, J. A. (1965) · American Journal of Enology and Viticulture · doi:10.5344/ajev.1965.16.3.144 · Cited by 24,852
The Chemistry behind Antioxidant Capacity Assays
Huang, D., Ou, B., & Prior, R. L. (2005) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf030723c · Cited by 6,162
Cited by
Bibi Sadeer, N., Montesano, D., Albrizio, S., Zengin, G., & Mahomoodally, M. F. (2020) · Antioxidants · doi:10.3390/antiox9080709 · Cited by 647
Apak, R., Gorinstein, S., Böhm, V., Schaich, K. M., Özyürek, M., & Güçlü, K. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rep-12-07-15 · Cited by 586
Self-citationDiniz do Nascimento, L., Moraes, A. A. B. D., Costa, K. S. D., Pereira Galúcio, J. M., Taube, P. S., Costa, C. M. L., Neves Cruz, J., de Aguiar Andrade, E. H., & Faria, L. J. G. D. (2020) · Biomolecules · doi:10.3390/biom10070988 · Cited by 470
Flieger, J., Flieger, W., Baj, J., & Maciejewski, R. (2021) · Materials · doi:10.3390/ma14154135 · Cited by 441
Analytical Methods for Lipid Oxidation and Antioxidant Capacity in Food Systems
Abeyrathne, E. D. N. S., Nam, K., & Ahn, D. U. (2021) · Antioxidants · doi:10.3390/antiox10101587 · Cited by 365
Metadata
- Authors
- Özyürek, M., Güçlü, K., Tütem, E., Başkan, K. S., Erçağ, E., Esin Çelik, S., Baki, S., Yıldız, L., Karaman, Ş., & Apak, R.
- Venue
- Analytical Methods
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 3
- Issue
- 11
- Pages
- 2439
- ISSN
- 1759-9660 (ISSN-L)
- 1759-9679
- OpenAlex
- W1969367526
- Cited by
- 233
- References
- 2
- FWCI
- 2.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comprehensive review of CUPRAC methodology. https://app.cochat.ai/papers/10.1039/c1ay05320e
- The paper
- Özyürek, M., Güçlü, K., Tütem, E., Başkan, K. S., Erçağ, E., Esin Çelik, S., Baki, S., Yıldız, L., Karaman, Ş., & Apak, R. (2011). A comprehensive review of CUPRAC methodology. Analytical Methods. https://doi.org/10.1039/c1ay05320e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.