The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Fluorescence and visual sensing of nitroaromatic explosives using electron rich discrete fluorophores
Abstract
Several π-electron rich fluorescent aromatic compounds containing trimethylsilylethynyl functionality have been synthesized by employing Sonogashira coupling reaction and they were characterized fully by NMR (1H, 13C)/IR spectroscopy. Incorporation of bulky trimethylsilylethynyl groups on the peripheral of the fluorophores prevents self-quenching of the initial intensity through π–π interaction and thereby maintains the spectroscopic stability in solution. These compounds showed fluorescence behavior in chloroform solution and were used as selective fluorescence sensors for the detection of electron deficient nitroaromatics. All these fluorophores showed the largest quenching response with high selectivity for nitroaromatics among the various electron deficient aromatic compounds tested. Quantitative analysis of the fluorescence titration profile of 9,10-bis(trimethylsilylethynyl)anthracene with picric acid provided evidence that this particular fluorophore detects picric acid even at ppb level. A sharp visual detection of 2,4,6-trinitrotoluene was observed upon subjecting 1,3,6,8-tetrakis(trimethylsilylethynyl)pyrene fluorophore to increasing quantities of 2,4,6-trinitrotoluene in chloroform. Furthermore, thin film of the fluorophores was made by spin coating of a solution of 1.0 × 10−3 M in chloroform or dichloromethane on a quartz plate and was used for the detection of vapors of nitroaromatics at room temperature. The vapor-phase sensing experiments suggested that the sensing process is reproducible and quite selective for nitroaromatic compounds. Selective fluorescence quenching response including a sharp visual color change for nitroaromatics makes these fluorophores as promising fluorescence sensory materials for nitroaromatic compounds (NAC) with a detection limit of even ppb level as judged with picric acid.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Chemical Sensors Based on Amplifying Fluorescent Conjugated Polymers
Thomas, S. W., Joly, G. D., & Swager, T. M. (2007) · Chemical Reviews · doi:10.1021/cr0501339 · Cited by 4,198
Conjugated Polymer-Based Chemical Sensors
McQuade, D. T., Pullen, A. E., & Swager, T. M. (2000) · Chemical Reviews · doi:10.1021/cr9801014 · Cited by 3,718
Photophysics of aromatic molecules
Birks, J. B. (1970) · Cited by 3,363
Tools and Tactics for the Optical Detection of Mercuric Ion
Nolan, E. M., & Lippard, S. J. (2008) · Chemical Reviews · doi:10.1021/cr068000q · Cited by 2,345
Zhao, Y., & Truhlar, D. G. (2004) · The Journal of Physical Chemistry A · doi:10.1021/jp048147q · Cited by 1,548
A colorimetric sensor array for odour visualization
Rakow, N. A., & Suslick, K. S. (2000) · Nature · doi:10.1038/35021028 · Cited by 1,490
Cross-Reactive Chemical Sensor Arrays
Albert, K. J., Lewis, N. S., Schauer, C. L., Sotzing, G. A., Stitzel, S. E., Vaid, T. P., & Walt, D. R. (2000) · Chemical Reviews · doi:10.1021/cr980102w · Cited by 1,284
Chen, J., Law, C. C. W., Lam, J. W. Y., Dong, Y., Lo, S. M. F., Williams, I. D., Zhu, D., & Tang, B. Z. (2003) · Chemistry of Materials · doi:10.1021/cm021715z · Cited by 1,190
Fluorescent Porous Polymer Films as TNT Chemosensors: Electronic and Structural Effects
Yang, J.-S., & Swager, T. M. (1998) · Journal of the American Chemical Society · doi:10.1021/ja982293q · Cited by 1,188
Cited by
Fluorescence based explosive detection: from mechanisms to sensory materials
Sun, X., Wang, Y., & Lei, Y. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00496a · Cited by 1,243
Fluorescent Tris-Imidazolium Sensors for Picric Acid Explosive
Roy, B., Bar, A. K., Gole, B., & Mukherjee, P. S. (2013) · The Journal of Organic Chemistry · doi:10.1021/jo302585a · Cited by 278
Self-citationA fluorescent organic cage for picric acid detection
Acharyya, K., & Mukherjee, P. S. (2014) · Chem. Commun. · doi:10.1039/c4cc06225f · Cited by 267
Self-citation
Metadata
- Authors
- Shanmugaraju, S., Joshi, S. A., & Mukherjee, P. S.
- Venue
- Journal of Materials Chemistry
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 21
- Issue
- 25
- Pages
- 9130
- ISSN
- 0959-9428 (ISSN-L)
- 1364-5501
- OpenAlex
- W2123672111
- Cited by
- 252
- References
- 34
- FWCI
- 8.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.