An integrated microfluidic device for two-dimensional combinatorial dilution
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
High-throughput preparation of multi-component solutions is an integral process in biology, chemistry and materials science for screening, diagnostics and analysis. Compact microfluidic systems enable such processing with low reagent volumes and rapid testing. Here we present a microfluidic device that incorporates two gradient generators, a tree-like generator and a new microfluidic active injection system, interfaced by intermediate solution reservoirs to generate diluted combinations of input solutions within an 8 × 8 or 10 × 10 array of isolated test chambers. Three input solutions were fed into the device, two to the tree-like gradient generator and one to pre-fill the test chamber array. The relative concentrations of these three input solutions in the test chambers completely characterized device behaviour and were controlled by the number of injection cycles and the flow rate. Device behaviour was modelled by computational fluid dynamics simulations and an approximate analytic formula. The device may be used for two-dimensional (2D) combinatorial dilution by adding two solutions in different relative concentrations to each of its three inputs. By appropriate choice of the two-component input solutions, test chamber concentrations that span any triangle in 2D concentration space may be obtained. In particular, explicit inputs are given for a coarse screening of a large region in concentration space followed by a more refined screening of a smaller region, including alternate inputs that span the same concentration region but with different distributions. The ability to probe arbitrary subspaces of concentration space and to control the distribution of discrete test points within those subspaces makes the device of potential benefit for high-throughput cell biology studies and drug screening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of redox potential and pH on arsenic speciation and solubility in a contaminated soil
Masscheleyn, P. H., Delaune, R. D., & Patrick, W. H. (1991) · Environmental Science & Technology · doi:10.1021/es00020a008 · Cited by 1,073
Nanoliter-scale synthesis of arrayed biomaterials and application to human embryonic stem cells
Anderson, D. G., Levenberg, S., & Langer, R. (2004) · Nature Biotechnology · doi:10.1038/nbt981 · Cited by 747
Biomolecular gradients in cell culture systems
Keenan, T. M., & Folch, A. (2008) · Lab Chip · doi:10.1039/b711887b · Cited by 596
A microfluidic multi-injector for gradient generation
Chung, B. G., Lin, F., & Jeon, N. L. (2006) · Lab on a Chip · doi:10.1039/b512667c · Cited by 104
Cited by
Biomimetic tissues on a chip for drug discovery
Ghaemmaghami, A. M., Hancock, M. J., Harrington, H., Kaji, H., & Khademhosseini, A. (2012) · Drug Discovery Today · doi:10.1016/j.drudis.2011.10.029 · Cited by 359
“developed a microfluidic combinatorial system that produced 64 or 100 combinations of two chemical solutions at different concentrations and stored them in isolated chambers [83].”
BackgroundSelf-citationAnimal tissue culture principles and applications
Verma, A., Verma, M., & Singh, A. (2020) · Animal Biotechnology · doi:10.1016/b978-0-12-811710-1.00012-4 · Cited by 161
A convection-driven long-range linear gradient generator with dynamic control
Wang, H., Chen, C.-H., Xiang, Z., Wang, M., & Lee, C. (2015) · Lab on a Chip · doi:10.1039/c4lc01451k · Cited by 40
Metadata
- Authors
- Jang, Y.-H., Hancock, M. J., Kim, S. B., Selimović, Š., Sim, W. Y., Bae, H., & Khademhosseini, A.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 11
- Issue
- 19
- Pages
- 3277
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2088751545
- Cited by
- 50
- References
- 4
- FWCI
- 3.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An integrated microfluidic device for two-dimensional combinatorial dilution. https://app.cochat.ai/papers/10.1039/c1lc20449a
- The paper
- Jang, Y.-H., Hancock, M. J., Kim, S. B., Selimović, Š., Sim, W. Y., Bae, H., & Khademhosseini, A. (2011). An integrated microfluidic device for two-dimensional combinatorial dilution. Lab on a Chip. https://doi.org/10.1039/c1lc20449a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.