The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Acoustofluidics 5: Building microfluidic acoustic resonators
Abstract
Acoustophoresis is getting more attention as an effective and gentle non-contact method of manipulating cells and particles in microfluidic systems. A key to a successful assembly of an acoustophoresis system is a proper design of the acoustic resonator where aspects of fabrication techniques, material choice, thickness matching of involved components, as well as strategies of actuation, all have to be considered. This tutorial covers some of the basics in designing and building microfluidic acoustic resonators and will hopefully be a comprehensive and advisory document to assist the interested reader in creating a successful acoustophoretic device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chip integrated strategies for acoustic separation and manipulation of cells and particles
Laurell, T., Petersson, F., & Nilsson, A. (2007) · Chem. Soc. Rev. · doi:10.1039/b601326k · Cited by 874
Self-citationContinuous particle separation in a microfluidic channel via standing surface acoustic waves (SSAW)
Shi, J., Huang, H., Stratton, Z., Huang, Y., & Huang, T. J. (2009) · Lab on a Chip · doi:10.1039/b915113c · Cited by 547
Review of cell and particle trapping in microfluidic systems
Nilsson, J., Evander, M., Hammarström, B., & Laurell, T. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.07.017 · Cited by 534
Self-citationContinuous separation of cells and particles in microfluidic systems
Lenshof, A., & Laurell, T. (2010) · Chemical Society Reviews · doi:10.1039/b915999c · Cited by 528
Self-citationFocusing microparticles in a microfluidic channel with standing surface acoustic waves (SSAW)
Shi, J., Mao, X., Ahmed, D., Colletti, A., & Huang, T. J. (2008) · Lab Chip · doi:10.1039/b716321e · Cited by 439
Separation of lipids from blood utilizing ultrasonic standing waves in microfluidic channels
Petersson, F., Nilsson, A., Holm, C., Jönsson, H., & Laurell, T. (2004) · The Analyst · doi:10.1039/b409139f · Cited by 330
Self-citationNoninvasive Acoustic Cell Trapping in a Microfluidic Perfusion System for Online Bioassays
Evander, M., Johansson, L., Lilliehorn, T., Piskur, J., Lindvall, M., Johansson, S., Almqvist, M., Laurell, T., & Nilsson, J. (2007) · Analytical Chemistry · doi:10.1021/ac061576v · Cited by 281
Self-citationWang, Z., & Zhe, J. (2011) · Lab on a Chip · doi:10.1039/c0lc00527d · Cited by 258
Hultström, J., Manneberg, O., Dopf, K., Hertz, H. M., Brismar, H., & Wiklund, M. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2006.07.024 · Cited by 220
A silicon microfluidic ultrasonic separator
Harris, N. R., Hill, M., Beeby, S., Shen, Y., White, N. M., Hawkes, J. J., & Coakley, W. T. (2003) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(03)00448-9 · Cited by 164
Cited by
Acoustofluidics 7: The acoustic radiation force on small particles
Bruus, H. (2012) · Lab on a Chip · doi:10.1039/c2lc21068a · Cited by 1,019
On-chip manipulation of single microparticles, cells, and organisms using surface acoustic waves
Ding, X., Lin, S.-C. S., Kiraly, B., Yue, H., Li, S., Chiang, I.-K., Shi, J., Benkovic, S. J., & Huang, T. J. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1209288109 · Cited by 912
Acoustic tweezers for the life sciences
Ozcelik, A., Rufo, J., Guo, F., Gu, Y., Li, P., Lata, J., & Huang, T. J. (2018) · Nature Methods · doi:10.1038/s41592-018-0222-9 · Cited by 826
Acoustofluidic separation of cells and particles
Wu, M., Ozcelik, A., Rufo, J., Wang, Z., Fang, R., & Jun Huang, T. (2019) · Microsystems & Nanoengineering · doi:10.1038/s41378-019-0064-3 · Cited by 453
Acoustofluidics 8: Applications of acoustophoresis in continuous flow microsystems
Lenshof, A., Magnusson, C., & Laurell, T. (2012) · Lab on a Chip · doi:10.1039/c2lc21256k · Cited by 353
Self-citationZhang, P., Bachman, H., Ozcelik, A., & Huang, T. J. (2020) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-090919-102205 · Cited by 316
Acoustofluidics for biomedical applications
Rufo, J., Cai, F., Friend, J., Wiklund, M., & Huang, T. J. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00109-7 · Cited by 305
Micro/nano acoustofluidics: materials, phenomena, design, devices, and applications
Connacher, W., Zhang, N., Huang, A., Mei, J., Zhang, S., Gopesh, T., & Friend, J. (2018) · Lab on a Chip · doi:10.1039/c8lc00112j · Cited by 269
Ultrasonic Based Tissue Modelling and Engineering
Olofsson, K., Hammarström, B., & Wiklund, M. (2018) · Micromachines · doi:10.3390/mi9110594 · Cited by 39
Li, X., Chen, J., Yang, Y., Cai, H., Ao, Z., Xing, Y., Li, K., Yang, K., Guan, W., Friend, J., et al. (2025) · Microsystems & Nanoengineering · doi:10.1038/s41378-025-00916-4 · Cited by 17
Metadata
- Authors
- Lenshof, A., Evander, M., Laurell, T., & Nilsson, J.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 4
- Pages
- 684
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2086896131
- Cited by
- 252
- References
- 22
- FWCI
- 9.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.