The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Antibody orientation on biosensor surfaces: a minireview
Open accessAbstract
Detection elements play a key role in analyte recognition in biosensors. Therefore, detection elements with high analyte specificity and binding strength are required. While antibodies (Abs) have been increasingly used as detection elements in biosensors, a key challenge remains - the immobilization on the biosensor surface. This minireview highlights recent approaches to immobilize and study Abs on surfaces. We first introduce Ab species used as detection elements, and discuss techniques recently used to elucidate Ab orientation by determination of layer thickness or surface topology. Then, several immobilization methods will be presented: non-covalent and covalent surface attachment, yielding oriented or random coupled Abs. Finally, protein modification methods applicable for oriented Ab immobilization are reviewed with an eye to future application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Enzyme-linked immunosorbent assay (ELISA) quantitative assay of immunoglobulin G
Engvall, E., & Perlmann, P. (1971) · Immunochemistry · doi:10.1016/0019-2791(71)90454-x · Cited by 3,777
Naturally occurring antibodies devoid of light chains
Hamers-Casterman, C., Atarhouch, T., Muyldermans, S., Robinson, G., Hammers, C., Songa, E. B., Bendahman, N., & Hammers, R. (1993) · Nature · doi:10.1038/363446a0 · Cited by 3,241
Cell Surface Engineering by a Modified Staudinger Reaction
Saxon, E., & Bertozzi, C. R. (2000) · Science · doi:10.1126/science.287.5460.2007 · Cited by 2,460
Cu-free click cycloaddition reactions in chemical biology
Jewett, J. C., & Bertozzi, C. R. (2010) · Chemical Society Reviews · doi:10.1039/b901970g · Cited by 1,684
Stereoselective Organic Reactions in Water
Lindström, U. M. (2002) · Chemical Reviews · doi:10.1021/cr010122p · Cited by 1,642
Expressed protein ligation: A general method for protein engineering
Muir, T. W., Sondhi, D., & Cole, P. A. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.12.6705 · Cited by 1,189
Kiick, K. L., Saxon, E., Tirrell, D. A., & Bertozzi, C. R. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.012583299 · Cited by 910
Greenberg, A. S., Avila, D., Hughes, M., Hughes, A., McKinney, E. C., & Flajnik, M. F. (1995) · Nature · doi:10.1038/374168a0 · Cited by 775
Addition of p-Azido-l-phenylalanine to the Genetic Code of Escherichia coli
Chin, J. W., Santoro, S. W., Martin, A. B., King, D. S., Wang, L., & Schultz, P. G. (2002) · Journal of the American Chemical Society · doi:10.1021/ja027007w · Cited by 721
Hernandez, K., & Fernandez-Lafuente, R. (2011) · Enzyme and Microbial Technology · doi:10.1016/j.enzmictec.2010.10.003 · Cited by 614
Chemical Strategies for Generating Protein Biochips
Jonkheijm, P., Weinrich, D., Schröder, H., Niemeyer, C. M., & Waldmann, H. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200801711 · Cited by 590
Bioconjugation with Strained Alkenes and Alkynes
Debets, M. F., van Berkel, S. S., Dommerholt, J., Dirks, A. (. J., Rutjes, F. P. J. T., & van Delft, F. L. (2011) · Accounts of Chemical Research · doi:10.1021/ar200059z · Cited by 564
Antibody production, design and use for biosensor-based applications
Conroy, P. J., Hearty, S., Leonard, P., & O’Kennedy, R. J. (2009) · Seminars in Cell & Developmental Biology · doi:10.1016/j.semcdb.2009.01.010 · Cited by 314
Practical Synthesis of Amides from In Situ Generated Copper(I) Acetylides and Sulfonyl Azides
Cassidy, M. P., Raushel, J., & Fokin, V. V. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200503805 · Cited by 282
Tajima, N., Takai, M., & Ishihara, K. (2011) · Analytical Chemistry · doi:10.1021/ac1026786 · Cited by 211
Bundy, B. C., & Swartz, J. R. (2010) · Bioconjugate Chemistry · doi:10.1021/bc9002844 · Cited by 194
Vashist, S. K., Dixit, C. K., MacCraith, B. D., & O'Kennedy, R. (2011) · The Analyst · doi:10.1039/c1an15325k · Cited by 179
Antibody Fragments as Probe in Biosensor Development
Saerens, D., Huang, L., Bonroy, K., & Muyldermans, S. (2008) · Sensors · doi:10.3390/s8084669 · Cited by 169
Preparation of unnatural N-to-N and C-to-C protein fusions
Witte, M. D., Cragnolini, J. J., Dougan, S. K., Yoder, N. C., Popp, M. W., & Ploegh, H. L. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1205427109 · Cited by 138
Adsorption and Bioactivity of Protein A on Silicon Surfaces Studied by AFM and XPS
Coen, M. C., Lehmann, R., Gröning, P., Bielmann, M., Galli, C., & Schlapbach, L. (2001) · Journal of Colloid and Interface Science · doi:10.1006/jcis.2000.7240 · Cited by 98
Yoshimoto, K., Nishio, M., Sugasawa, H., & Nagasaki, Y. (2010) · Journal of the American Chemical Society · doi:10.1021/ja910372e · Cited by 93
Nanobodies ® : proficient tools in diagnostics
Huang, L., Muyldermans, S., & Saerens, D. (2010) · Expert Review of Molecular Diagnostics · doi:10.1586/erm.10.62 · Cited by 91
Protein Biochips: Oriented Surface Immobilization of Proteins
Lin, P., Weinrich, D., & Waldmann, H. (2009) · Macromolecular Chemistry and Physics · doi:10.1002/macp.200900539 · Cited by 90
Analysis of adsorbed proteins by static time-of-flight secondary ion mass spectrometry
Wagner, M. S., & Castner, D. G. (2004) · Applied Surface Science · doi:10.1016/j.apsusc.2004.03.100 · Cited by 81
General Method for Site-Specific Protein Immobilization by Staudinger Ligation
Kalia, J., Abbott, N. L., & Raines, R. T. (2007) · Bioconjugate Chemistry · doi:10.1021/bc0603034 · Cited by 73
A novel biosensor based on serum antibody immobilization for rapid detection of viral antigens
Huy, T. Q., Hạnh, N. T. H., Thủy, N. T., Chung, P. V., Nga, P. T., & Anh, T. M. (2011) · Talanta · doi:10.1016/j.talanta.2011.09.012 · Cited by 68
Han, H. J., Kannan, R. M., Wang, S., Mao, G., Kusanovic, J. P., & Romero, R. J. (2010) · Advanced Functional Materials · doi:10.1002/adfm.200901293 · Cited by 68
Ryu, Y., Jin, Z., Kang, M. S., & Kim, H. (2011) · BioChip Journal · doi:10.1007/s13206-011-5301-2 · Cited by 62
Bioconjugation of Protein-Repellent Zwitterionic Polymer Brushes Grafted from Silicon Nitride
Nguyen, A. T., Baggerman, J., Paulusse, J. M. J., Zuilhof, H. T., & van Rijn, C. J. M. (2011) · Langmuir · doi:10.1021/la2031363 · Cited by 62
Self-citationYoo, E. M., Chintalacharuvu, K. R., Penichet, M. L., & Morrison, S. L. (2002) · Journal of Immunological Methods · doi:10.1016/s0022-1759(01)00559-2 · Cited by 61
The structural orientation of antibody layers bound to engineered biosensor surfaces
Brun, A. P. L., Holt, S. A., Shah, D. S. H., Majkrzak, C. F., & Lakey, J. H. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.01.026 · Cited by 53
Recombinant Antibodies for the Generation of Antibody Arrays
Borrebaeck, C. A. K., & Wingren, C. (2011) · Methods in molecular biology · doi:10.1007/978-1-61779-286-1_17 · Cited by 45
Surface immobilization of biomolecules by click sulfonamide reaction
Govindaraju, T., Jonkheijm, P., Gogolin, L., Schroeder, H., Becker, C. F. W., Niemeyer, C. M., & Waldmann, H. (2008) · Chemical Communications · doi:10.1039/b806764c · Cited by 43
SPR biosensor by using E. coli outer membrane layer with autodisplayed Z-domains
Park, M., Jose, J., & Pyun, J. (2010) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2010.03.039 · Cited by 35
Harmsen, M. M., & Fijten, H. (2012) · Journal of Immunoassay and Immunochemistry · doi:10.1080/15321819.2011.634473 · Cited by 23
Yuan, Y., Yin, M., Qian, J., & Liu, C. (2011) · Soft Matter · doi:10.1039/c1sm05086a · Cited by 19
Cited by
Protein Interactions with Polymer Coatings and Biomaterials
Wei, Q., Becherer, T., Angioletti‐Uberti, S., Dzubiella, J., Wischke, C., Neffe, A. T., Lendlein, A., Ballauff, M., & Haag, R. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201400546 · Cited by 743
Ultrasensitive and Highly Specific Lateral Flow Assays for Point-of-Care Diagnosis
Liu, Y., Zhan, L., Qin, Z., Sackrison, J., & Bischof, J. C. (2021) · ACS Nano · doi:10.1021/acsnano.0c10035 · Cited by 626
Optical Biosensors Based on Plasmonic Nanostructures: A Review
Spackova, B., Wrobel, P., Bockova, M., & Homola, J. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2624340 · Cited by 421
Orientation and characterization of immobilized antibodies for improved immunoassays (Review)
Welch, N. G., Scoble, J. A., Muir, B. W., & Pigram, P. J. (2017) · Biointerphases · doi:10.1116/1.4978435 · Cited by 414
Antibodies and antibody-derived analytical biosensors
Sharma, S., Byrne, H., & O'Kennedy, R. J. (2016) · Essays in Biochemistry · doi:10.1042/ebc20150002 · Cited by 396
Metadata
- Authors
- Trilling, A. K., Beekwilder, J., & Zuilhof, H.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 138
- Issue
- 6
- Pages
- 1619
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2056066120
- Cited by
- 466
- References
- 36
- FWCI
- 13.72
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.