CoChat

Optimization of UA-DLLME by experimental design methodologies for the simultaneous determination of endosulfan and its metabolites in soil and urine samples by GC–MS

Reddy Mudiam, Mohana Krishna, Ch, Ratnasekhar, Chauhan, Abhishek, Manickam, Natesan, Jain, Rajeev, Murthy, R. C. · 2012 · Analytical Methods
Cited by 24

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

A simple, economical, rapid and sensitive analytical method has been developed for the simultaneous determination of endosulfan (α- and β-) and its metabolites (endosulfan ether, endosulfan hydroxy ether, endosulfan lactone, endosulfan alcohol and endosulfan sulphate) in complex samples, such as soil and urine, based on ultrasound assisted dispersive liquid–liquid microextraction (UA-DLLME) followed by gas chromatography–mass spectrometric (GC–MS) analysis. The method parameters have been optimized using response surface design experiments. Trichloroethylene (TCE) and acetone were chosen as extraction and disperser solvents respectively. After UA-DLLME, the sediment phase obtained was directly analyzed by GC–MS without any further cleanup and preconcentration procedure. Several factors which can affect the UA-DLLME extraction were screened and optimized by 27–4 Plackett–Burman design (PBD) and central composite design (CCD) experiments respectively. Based on these experiments the optimized parameters for UA-DLLME extraction were as follows: extraction solvent, (TCE, 58 μL), disperser solvent (acetone, 1.27 mL) and ionic strength (Na2SO4, 7%, w/v). Intra- and inter-day precision were expressed as percent relative standard deviation (% RSD) and were found to be less than 6.33%. The limit of detection (LOD) of all the analytes in soil and urine were found to be in the range of 0.316–2.494 ng g−1 and 0.049–0.514 ng mL−1 respectively. The proposed method was successfully applied in the analysis of soil samples contaminated with endosulfan. The method may find wide application for the routine determination of endosulfan and its metabolites in environmental and biological samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c2ay25432h

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Reddy Mudiam, M. K., Ch, R., Chauhan, A., Manickam, N., Jain, R., & Murthy, R. C.
Venue
Analytical Methods
Published
2012
Volume
4
Issue
11
Pages
3855
ISSN
  • 1759-9660 (ISSN-L)
  • 1759-9679
OpenAlex
W1964090083
Cited by
24
References
3
FWCI
2.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.