The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Spectroscopic probes with changeable π-conjugated systems
Abstract
Spectroscopic probes have been extensively investigated and used widely in many fields because of their powerful ability to improve analytical sensitivity, and to offer greater temporal and spatial resolution (in some cases a molecule event may be visualized by the naked eye). So far, different photophysical mechanisms, such as charge transfer, photo-induced electron transfer and fluorescent resonance energy transfer, have been employed to develop various spectroscopic probes with superior properties. However, these photophysical mechanisms depend on the energy levels of molecular orbitals, which are usually difficult to accurately determine. This would lead to the poor prediction of analytical performance of the designed probe. Instead, the change of π-conjugated systems induced by chemical reactions is often accompanied by a distinct alteration in spectroscopic signal, which is more predictable and is of high signal/background ratio. This mechanism can serve as an effective measure for developing excellent spectroscopic probes, but to our knowledge, has not been systematically summarized. In this feature article, we review the development of spectroscopic probes with changeable π-conjugated systems, which is catalogued according to the fluorochromes: fluorescein, rhodamine, spiropyran, squaraine, coumarin, cyanine, etc. Two main strategies for constructing these spectroscopic probes, including ring-closing reaction and nucleophilic addition reaction, are summarized, and the merits and limitations of the probes are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluorescent and luminescent probes for detection of reactive oxygen and nitrogen species
Chen, X., Tian, X., Shin, I., & Yoon, J. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15037e · Cited by 980
Chen, X., Lee, K.-A., Ha, E.-M., Lee, K. M., Seo, Y. Y., Choi, H. K., Kim, H. N., Kim, M. J., Cho, C.-S., Lee, S. Y., et al. (2011) · Chemical Communications · doi:10.1039/c1cc10589b · Cited by 246
A design of fluorescent probes for superoxide based on a nonredox mechanism
Maeda, H., Yamamoto, K., Nomura, Y., Kohno, I., Hafsi, L., Ueda, N., Yoshida, S., Fukuda, M., Fukuyasu, Y., Yamauchi, Y., et al. (2005) · Journal of the American Chemical Society · doi:10.1021/ja047018k · Cited by 196
Maeda, H., Yamamoto, K., Kohno, I., Hafsi, L., Itoh, N., Nakagawa, S., Kanagawa, N., Suzuki, K., & Uno, T. (2007) · Chemistry – A European Journal · doi:10.1002/chem.200600522 · Cited by 85
Cited by
Yu, F., Li, P., Wang, B., & Han, K. (2013) · Journal of the American Chemical Society · doi:10.1021/ja401360a · Cited by 621
Advances in targeting the folate receptor in the treatment/imaging of cancers
Fernández, M., Javaid, F., & Chudasama, V. (2018) · Chemical Science · doi:10.1039/c7sc04004k · Cited by 539
Chemically diverse small molecule fluorescent chemosensors for copper ion
Sivaraman, G., Iniya, M., Anand, T., Kotla, N. G., Sunnapu, O., Singaravadivel, S., Gulyani, A., & Chellappa, D. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2017.11.020 · Cited by 391
Hemicyanine‐Based Near‐Infrared Activatable Probes for Imaging and Diagnosis of Diseases
Zeng, Z., Liew, S. S., Wei, X., & Pu, K. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202107877 · Cited by 359
Recognition Moieties of Small Molecular Fluorescent Probes for Bioimaging of Enzymes
Wu, X., Shi, W., Li, X., & Ma, H. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.9b00214 · Cited by 284
Self-citation
Metadata
- Authors
- Shi, W., & Ma, H.
- Venue
- Chemical Communications
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 48
- Issue
- 70
- Pages
- 8732
- ISSN
- 1359-7345 (ISSN-L)
- 1364-548X
- OpenAlex
- W2088765918
- Cited by
- 164
- References
- 4
- FWCI
- 8.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.