Mass spectrometry based tools to investigate protein–ligand interactions for drug discovery
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The initial stages of drug discovery are increasingly reliant on development and improvement of analytical methods to investigate protein-protein and protein-ligand interactions. For over 20 years, mass spectrometry (MS) has been recognized as providing a fast, sensitive and high-throughput methodology for analysis of weak non-covalent complexes. Careful control of electrospray ionization conditions has enabled investigation of the structure, stability and interactions of proteins and peptides in a solvent free environment. This critical review covers the use of mass spectrometry for kinetic, dynamic and structural studies of proteins and protein complexes. We discuss how conjunction of mass spectrometry with related techniques and methodologies such as ion mobility, hydrogen-deuterium exchange (HDX), protein footprinting or chemical cross-linking can provide us with structural information useful for drug development. Along with other biophysical techniques, such as NMR or X-ray crystallography, mass spectrometry provides a powerful toolbox for investigation of biological problems of medical relevance (204 references).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
How many drug targets are there?
Overington, J. P., Al-Lazikani, B., & Hopkins, A. L. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd2199 · Cited by 3,505
Structural Basis of Transcription: RNA Polymerase II at 2.8 Ångstrom Resolution
Cramer, P., Bushnell, D. A., & Kornberg, R. D. (2001) · Science · doi:10.1126/science.1059493 · Cited by 1,247
A Tandem Mass Spectrometer for Improved Transmission and Analysis of Large Macromolecular Assemblies
Sobott, F., Hernández, H., McCammon, M. G., Tito, M. A., & Robinson, C. V. (2002) · Analytical Chemistry · doi:10.1021/ac0110552 · Cited by 511
Lanman, J., Lam, T. T., Barnes, S., Sakalian, M., Emmett, M. R., Marshall, A. G., & Prevelige, P. E. (2003) · Journal of Molecular Biology · doi:10.1016/s0022-2836(02)01245-7 · Cited by 206
Norwalk Virus Assembly and Stability Monitored by Mass Spectrometry
Shoemaker, G. K., van Duijn, E., Crawford, S. E., Uetrecht, C., Baclayon, M., Roos, W. H., Wuite, G. J. L., Estes, M. K., Prasad, B. V. V., & Heck, A. J. R. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900620-mcp200 · Cited by 140
Cited by
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Susa, A. C., Xia, Z., & Williams, E. R. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04897 · Cited by 167
Intrinsic GTPase activity of K-RAS monitored by native mass spectrometry
Moghadamchargari, Z., Huddleston, J., Shirzadeh, M., Zheng, X., Clemmer, D. E., M. Raushel, F., Russell, D. H., & Laganowsky, A. (2019) · Biochemistry · doi:10.1021/acs.biochem.9b00532 · Cited by 38
Metadata
- Authors
- Pacholarz, K. J., Garlish, R. A., Taylor, R. J., & Barran, P. E.
- Venue
- Chemical Society Reviews
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 41
- Issue
- 11
- Pages
- 4335
- ISSN
- 0306-0012 (ISSN-L)
- 1460-4744
- OpenAlex
- W2157436515
- Cited by
- 141
- References
- 6
- FWCI
- 0.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.