The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Far-red to near infrared analyte-responsive fluorescent probes based on organic fluorophore platforms for fluorescence imaging
Abstract
The long wavelength (far-red to NIR) analyte-responsive fluorescent probes are advantageous for in vivo bioimaging because of minimum photo-damage to biological samples, deep tissue penetration, and minimum interference from background auto-fluorescence by biomolecules in the living systems. Thus, great interest in the development of new long wavelength analyte-responsive fluorescent probes has emerged in recent years. This review highlights the advances in the development of far-red to NIR fluorescent probes since 2000, and the probes are classified according to their organic dye platforms into various categories, including cyanines, rhodamine analogues, BODIPYs, squaraines, and other types (240 references).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
BODIPY Dyes and Their Derivatives: Syntheses and Spectroscopic Properties
Loudet, A., & Burgess, K. (2007) · Chemical Reviews · doi:10.1021/cr078381n · Cited by 5,238
A clearer vision for in vivo imaging
Weissleder, R. (2001) · Nature Biotechnology · doi:10.1038/86684 · Cited by 3,839
Fluorescent and luminescent probes for detection of reactive oxygen and nitrogen species
Chen, X., Tian, X., Shin, I., & Yoon, J. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15037e · Cited by 980
Jacquemont, S., Curie, A., des Portes, V., Torrioli, M. G., Berry-Kravis, E., Hagerman, R. J., Ramos, F. J., Cornish, K., He, Y., Paulding, C., et al. (2011) · Science Translational Medicine · doi:10.1126/scitranslmed.3001708 · Cited by 609
Cited by
BODIPY-based probes for the fluorescence imaging of biomolecules in living cells
Kowada, T., Maeda, H., & Kikuchi, K. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00030k · Cited by 1,381
Polymer-encapsulated organic nanoparticles for fluorescence and photoacoustic imaging
Li, K., & Liu, B. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00014e · Cited by 987
Yu, F., Li, P., Wang, B., & Han, K. (2013) · Journal of the American Chemical Society · doi:10.1021/ja401360a · Cited by 621
Yin, J., Kwon, Y., Kim, D., Lee, D., Kim, G., Hu, Y., Ryu, J.-H., & Yoon, J. (2014) · Journal of the American Chemical Society · doi:10.1021/ja412628z · Cited by 599
Donor Engineering for NIR-II Molecular Fluorophores with Enhanced Fluorescent Performance
Yang, Q., Hu, Z., Zhu, S., Ma, R., Ma, H., Ma, Z., Wan, H., Zhu, T., Jiang, Z., Liu, W., et al. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.7b10334 · Cited by 554
Metadata
- Authors
- Yuan, L., Lin, W., Zheng, K., He, L., & Huang, W.
- Venue
- Chem. Soc. Rev.
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 42
- Issue
- 2
- Pages
- 622-661
- ISSN
- 0306-0012 (ISSN-L)
- 1460-4744
- OpenAlex
- W1967652154
- Cited by
- 1,822
- References
- 4
- FWCI
- 4.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.