The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
From “cyborg” lobsters to a pacemaker powered by implantable biofuel cells
Abstract
Enzyme-based biofuel cells implanted into living lobsters or designed as fluidic systems mimicking human blood circulation were used for powering electronic devices. Two lobsters with implanted biofuel cells connected in series were able to generate open circuit voltage (Voc) up to 1.2 V and an electrical watch, selected as a model electronic device, was activated by the power extracted from the “living battery”. The fluidic system composed of five cells filled with human serum solution connected in series generated Voc of ca. 3 V and was able to power a pacemaker. Sustainable operation of the pacemaker was achieved with the system closely mimicking human physiological conditions characteristic of normal and pathophysiological glucose concentrations with the fluidic rate typical for a blood circulation upon resting or performing physical exercises. While the “cyborg” lobsters demonstrate a model system with future possible military, homeland security and environmental monitoring applications, the system activating a pacemaker presents practicality for biomedical applications. The first demonstration of the pacemaker activated by the physiologically produced electrical energy shows promise for future electronic implantable medical devices powered by electricity harvested from the human body.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Logan, B. E. (2007) · Wiley eBooks · doi:10.1002/9780470258590 · Cited by 1,542
Enzymatic Biofuel Cells for Implantable and Microscale Devices
Calabrese Barton, S., Gallaway, J., & Atanassov, P. (2004) · Chemical Reviews · doi:10.1021/cr020719k · Cited by 1,394
Enzymes as Working or Inspirational Electrocatalysts for Fuel Cells and Electrolysis
Cracknell, J. A., Vincent, K. A., & Armstrong, F. A. (2008) · Chemical Reviews · doi:10.1021/cr0680639 · Cited by 988
Continuous Electricity Generation at High Voltages and Currents Using Stacked Microbial Fuel Cells
Aelterman, P., Rabaey, K., Pham, H. T., Boon, N., & Verstraete, W. (2006) · Environmental Science & Technology · doi:10.1021/es0525511 · Cited by 918
Heller, A. (2004) · Physical Chemistry Chemical Physics · doi:10.1039/b313149a · Cited by 660
Mediatorless high-power glucose biofuel cells based on compressed carbon nanotube-enzyme electrodes
Zebda, A., Gondran, C., Le Goff, A., Holzinger, M., Cinquin, P., & Cosnier, S. (2011) · Nature Communications · doi:10.1038/ncomms1365 · Cited by 615
Biofuel cells—Recent advances and applications
Davis, F., & Higson, S. P. J. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.04.029 · Cited by 591
Implanted Biofuel Cell Operating in a Living Snail
Halámková, L., Halámek, J., Bocharova, V., Szczupak, A., Alfonta, L., & Katz, E. (2012) · Journal of the American Chemical Society · doi:10.1021/ja211714w · Cited by 486
Self-citationA Glucose BioFuel Cell Implanted in Rats
Cinquin, P., Gondran, C., Giroud, F., Mazabrard, S., Pellissier, A., Boucher, F., Alcaraz, J.-P., Gorgy, K., Lenouvel, F., Mathé, S., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0010476 · Cited by 413
Energy harvesting by implantable abiotically catalyzed glucose fuel cells
Kerzenmacher, S., Ducrée, J., Zengerle, R., & von Stetten, F. (2008) · Journal of Power Sources · doi:10.1016/j.jpowsour.2008.03.031 · Cited by 374
Extended lifetime biofuel cells
Moehlenbrock, M. J., & Minteer, S. D. (2008) · Chemical Society Reviews · doi:10.1039/b708013c · Cited by 351
Soukharev, V., Mano, N., & Heller, A. (2004) · Journal of the American Chemical Society · doi:10.1021/ja0475510 · Cited by 310
An Implantable Biofuel Cell for a Live Insect
Rasmussen, M., Ritzmann, R. E., Lee, I., Pollack, A. J., & Scherson, D. (2012) · Journal of the American Chemical Society · doi:10.1021/ja210794c · Cited by 270
Living battery – biofuel cells operating in vivo in clams
Szczupak, A., Halámek, J., Halámková, L., Bocharova, V., Alfonta, L., & Katz, E. (2012) · Energy & Environmental Science · doi:10.1039/c2ee21626d · Cited by 259
Self-citationEnzymatic biofuel cells designed for direct power generation from biofluids in living organisms
Miyake, T., Haneda, K., Nagai, N., Yatagawa, Y., Onami, H., Yoshino, S., Abe, T., & Nishizawa, M. (2011) · Energy & Environmental Science · doi:10.1039/c1ee02200h · Cited by 246
A Glucose Fuel Cell for Implantable Brain–Machine Interfaces
Rapoport, B. I., Kedzierski, J. T., & Sarpeshkar, R. (2012) · PLoS ONE · doi:10.1371/journal.pone.0038436 · Cited by 242
Stressed-Out Lobsters: Crustacean Hyperglycemic Hormone and Stress Proteins
Chang, E. S. (2005) · Integrative and Comparative Biology · doi:10.1093/icb/45.1.43 · Cited by 162
Lorenzon, S., Giulianini, P. G., Martinis, M., & Ferrero, E. A. (2006) · Comparative Biochemistry and Physiology Part A Molecular & Integrative Physiology · doi:10.1016/j.cbpa.2006.11.028 · Cited by 151
Energy Harvesting With Microbial Fuel Cell and Power Management System
Meehan, A., Gao, H., & Lewandowski, Z. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2054114 · Cited by 151
In vivo whole-field blood velocity measurement techniques
Vennemann, P., Lindken, R., & Westerweel, J. (2007) · Experiments in Fluids · doi:10.1007/s00348-007-0276-4 · Cited by 150
A Miniature Membrane‐less Biofuel Cell Operating at +0.60 V under Physiological Conditions
Mano, N., Mao, F., & Heller, A. (2004) · ChemBioChem · doi:10.1002/cbic.200400275 · Cited by 148
Biofuel Cells for Portable Power
Gellett, W. L., Kesmez, M., Schumacher, J. D., Akers, N. L., & Minteer, S. D. (2010) · Electroanalysis · doi:10.1002/elan.200980013 · Cited by 119
Rincón, R. A., Lau, C., Luckarift, H. R., Garcia, K. E., Adkins, E., Johnson, G. R., & Atanassov, P. B. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.06.029 · Cited by 114
BioCapacitor—A novel category of biosensor
Hanashi, T., Yamazaki, T., Tsugawa, W., Ferri, S. R., Nakayama, D., Tomiyama, M., Ikebukuro, K., & Sode, K. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.09.014 · Cited by 77
A tissue implantable fuel cell power supply.
Drake, R. F., Bk, K., Messinger, S., & Matsuda, S. (1970) · PubMed · Cited by 75
Methylene Green Electrodeposited on SWNTs-Based “Bucky” Papers for NADH and l -Malate Oxidation
Villarrubia, C. W. N., Rincón, R. A., Radhakrishnan, V. K., Davis, V. A., & Atanassov, P. B. (2011) · ACS Applied Materials & Interfaces · doi:10.1021/am2003137 · Cited by 69
Clinical Cardiac Pacing, Defibrillation and Resynchronization Therapy
Ellenbogen, K. A. (2011) · Elsevier eBooks · doi:10.1016/c2009-0-44191-6 · Cited by 66
Evolution of power sources for implantable cardioverter defibrillators
Crespi, A. M., Somdahl, S. K., Schmidt, C., & Skarstad, P. M. (2001) · Journal of Power Sources · doi:10.1016/s0378-7753(01)00499-2 · Cited by 61
BioRadioTransmitter: A Self-Powered Wireless Glucose-Sensing System
Hanashi, T., Yamazaki, T., Tsugawa, W., Ikebukuro, K., & Sode, K. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500502 · Cited by 60
Mitochondrial biofuel cells: expanding fuel diversity to amino acids
Bhatnagar, D., Xu, S., Fischer, C. N., Arechederra, R. L., & Minteer, S. D. (2010) · Physical Chemistry Chemical Physics · doi:10.1039/c0cp01362e · Cited by 54
Scholz, F., & Schröder, U. (2003) · Nature Biotechnology · doi:10.1038/nbt1003-1151 · Cited by 51
Pacemakers charging using body energy
Bhatia, D., Bairagi, S., Goel, S., & Jangra, M. (2010) · Journal of Pharmacy And Bioallied Sciences · doi:10.4103/0975-7406.62713 · Cited by 49
Mesoporous silica as a membrane for ultra-thin implantable direct glucose fuel cells
Sharma, T., Hu, Y., Stoller, M. D., Feldman, M. D., Ruoff, R. S., Mauro Ferrari, B., & Zhang, X. (2011) · Lab on a Chip · doi:10.1039/c1lc20119k · Cited by 48
Simulation of Multistep Enzyme-Catalyzed Methanol Oxidation in Biofuel Cells
Kar, P., Wen, H., Li, H., Minteer, S. D., & Barton, S. C. (2011) · Journal of The Electrochemical Society · doi:10.1149/1.3561690 · Cited by 40
Cited by
Smart Textiles for Electricity Generation
Chen, G., Li, Y., Bick, M., & Chen, J. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00821 · Cited by 931
Liu, Z., Wan, X., Wang, Z. L., & Li, L. (2021) · Advanced Materials · doi:10.1002/adma.202007429 · Cited by 478
Single Glucose Biofuel Cells Implanted in Rats Power Electronic Devices
Zebda, A., Cosnier, S., Alcaraz, J.-P., Holzinger, M., Le Goff, A., Gondran, C., Boucher, F., Giroud, F., Gorgy, K., Lamraoui, H., et al. (2013) · Scientific Reports · doi:10.1038/srep01516 · Cited by 370
Functional Fiber Materials to Smart Fiber Devices
Chen, C., Feng, J., Li, J., Guo, Y., Shi, X., & Peng, H. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00192 · Cited by 308
Towards glucose biofuel cells implanted in human body for powering artificial organs: Review
Cosnier, S., Le Goff, A., & Holzinger, M. (2014) · Electrochemistry Communications · doi:10.1016/j.elecom.2013.09.021 · Cited by 291
Metadata
- Authors
- MacVittie, K., Halámek, J., Halámková, L., Southcott, M., Jemison, W. D., Lobel, R., & Katz, E.
- Venue
- Energy Environ. Sci.
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 6
- Issue
- 1
- Pages
- 81-86
- ISSN
- 1754-5692 (ISSN-L)
- 1754-5706
- OpenAlex
- W2072077307
- Cited by
- 332
- References
- 34
- FWCI
- 17.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.