The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A Glucose Fuel Cell for Implantable Brain–Machine Interfaces
Open accessAbstract
We have developed an implantable fuel cell that generates power through glucose oxidation, producing 3.4 μW cm(-2) steady-state power and up to 180 μW cm(-2) peak power. The fuel cell is manufactured using a novel approach, employing semiconductor fabrication techniques, and is therefore well suited for manufacture together with integrated circuits on a single silicon wafer. Thus, it can help enable implantable microelectronic systems with long-lifetime power sources that harvest energy from their surrounds. The fuel reactions are mediated by robust, solid state catalysts. Glucose is oxidized at the nanostructured surface of an activated platinum anode. Oxygen is reduced to water at the surface of a self-assembled network of single-walled carbon nanotubes, embedded in a Nafion film that forms the cathode and is exposed to the biological environment. The catalytic electrodes are separated by a Nafion membrane. The availability of fuel cell reactants, oxygen and glucose, only as a mixture in the physiologic environment, has traditionally posed a design challenge: Net current production requires oxidation and reduction to occur separately and selectively at the anode and cathode, respectively, to prevent electrochemical short circuits. Our fuel cell is configured in a half-open geometry that shields the anode while exposing the cathode, resulting in an oxygen gradient that strongly favors oxygen reduction at the cathode. Glucose reaches the shielded anode by diffusing through the nanotube mesh, which does not catalyze glucose oxidation, and the Nafion layers, which are permeable to small neutral and cationic species. We demonstrate computationally that the natural recirculation of cerebrospinal fluid around the human brain theoretically permits glucose energy harvesting at a rate on the order of at least 1 mW with no adverse physiologic effects. Low-power brain-machine interfaces can thus potentially benefit from having their implanted units powered or recharged by glucose fuel cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Energy Harvesting From Human and Machine Motion for Wireless Electronic Devices
Mitcheson, P. D., Yeatman, E. M., Rao, G. K., Holmes, A. S., & Green, T. C. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.927494 · Cited by 1,888
An Energy-Efficient Micropower Neural Recording Amplifier
Wattanapanitch, W., Fee, M., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.907868 · Cited by 441
Self-citationLow-Power Circuits for Brain–Machine Interfaces
Sarpeshkar, R., Wattanapanitch, W., Arfin, S. K., Rapoport, B. I., Mandal, S., Baker, M. W., Fee, M. S., Musallam, S., & Andersen, R. A. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2003198 · Cited by 91
Self-citation
Research works printed but not linked: 42
- R Sarpeshkar, 2005, An ultra-low-power programmable analog bionic ear processor., IEEE Transactions on Biomedical Engineering, 52, 711, 10.1109/TBME.2005.844043 · DOI · Paper page
- MW Baker, 2007, Feedback analysis and design of RF power links for low-power bionic systems., IEEE Transactions on Biomedical Circuits and Systems, 1, 28, 10.1109/TBCAS.2007.893180 · DOI · Paper page
- A Burke, 2000, Ultracapacitors: why, how, and where is the technology., Journal of Power Sources, 91, 37, 10.1016/S0378-7753(00)00485-7 · DOI · Paper page
- M Jayalakshmi, 2008, Simple capacitors to supercapacitors–an overview., International Journal of Electrochemical Science, 3, 1196, 10.1016/S1452-3981(23)15517-9 · DOI · Paper page
- NJ Dudney, 1999, Solid state thin-film lithium battery systems., Current Opinion in Solid State and Materials Science, 4, 479, 10.1016/S1359-0286(99)00052-2 · DOI
- V Lenov, 2007, Thermoelectric converters of human warmth for self-powered wireless sensor nodes., IEEE Sensors Journal, 7, 650, 10.1109/JSEN.2007.894917 · DOI · Paper page
- A Kurs, 2007, Wireless power transfer via strongly coupled magnetic resonances., Science, 317, 83, 10.1126/science.1143254 · DOI · Paper page
- S Mandal, 2007, Low-power CMOS rectifier design for RFID applications., IEEE Transactions on circuits and Systems I: Regular Papers, 54, 1177, 10.1109/TCSI.2007.895229 · DOI · Paper page
- R Sarpeshkar, 2010, Ultra Low Power Bioelectronics: Fundamentals, Biomedical Applications, and Bio-Inspired Systems., 10.1017/CBO9780511841446 · DOI · Paper page
- R Sarpeshkar, 2005, An ultra-low-power programmable analog bionic ear processor., IEEE Transactions on Biomedical Engineering, 52, 711, 10.1109/TBME.2005.844043 · DOI · Paper page
- B Rapoport, 2011, A Biomimetic Adaptive Algorithm and Micropower Circuit Architecture for Implantable Neural Decoders, IGI Global, chapter 10. 216–254.
- BI Rapoport, 2009, A biomimetic adaptive algorithm and low-power architecture for implantable neural decoders., 10.1109/IEMBS.2009.5333793 · DOI
- S Kerzenmacher, 2008, Energy harvesting by implantable abiotically catalyzed glucose fuel cells., Journal of Power Sources, 182, 1, 10.1016/j.jpowsour.2008.03.031 · DOI · Paper page
- A Heller, 2004, Miniature biofuel cells., Physical Chemistry Chemical Physics, 6, 209, 10.1039/b313149a · DOI · Paper page
- RA Bullen, 2006, Biofuel cells and their development., Biosensors and Bioelectronics, 21, 2015, 10.1016/j.bios.2006.01.030 · DOI · Paper page
- F Davis, 2007, Biofuel cells––Recent advances and applications., Biosensors and Bioelectronics, 22, 1224, 10.1016/j.bios.2006.04.029 · DOI · Paper page
- K Rabaey, 2004, Biofuel cells select for microbial consortia that self-mediate electron transfer., Applied and Environmental Microbiology, 70, 5373, 10.1128/AEM.70.9.5373-5382.2004 · DOI · Paper page
- J Niessen, 2004, Exploiting complex carbohydrates for microbial electricity generation––a bacterial fuel cell operating on starch., Electrochemistry Communications, 6, 955, 10.1016/j.elecom.2004.07.010 · DOI · Paper page
- MH Osman, 2010, Recent progress and continuing challenges in bio-fuel cells. Part II: Microbial., Biosensors and Bioelectronics, 26, 953, 10.1016/j.bios.2010.08.057 · doi:10.1016/j.bios.2010.08.057
- U Gebhardt, 1976, A special type of Raney-alloy catalyst used in compact biofuel cells., Journal of Applied Electrochemistry, 6, 127, 10.1007/BF00615377 · doi:10.1007/bf00615377
- RF Drake, 1970, A tissue implantable fuel cell power supply., Transactions of the American Society for Artificial Internal Organs (ASAIO Journal), 16, 199
- E Weidlich, 1976, Animal experiments with biogalvanic and biofuel cells., Biomaterials, Medical Devices, and Artificial Organs, 3–4, 227
- G Kim, 2009, Bacterial adhesion, cell adhesion and biocompatibility of Nafion films., Journal of Biomaterials Science, 20, 1687, 10.1163/156856208X386273 · DOI
- J Rishpon, 1994, Amperometric glucose sensors based on glucose oxidase immobilized in Nafion., Electroanalysis, 6, 17, 10.1002/elan.1140060105 · DOI
- JH An, 2008, Effects of glucose and glutamine concentration in the formulation of the artificial cerebrospinal uid (ACSF)., Brain Research, 1218, 77, 10.1016/j.brainres.2008.04.007 · DOI
- S Kerzenmacher, 2008, An abiotically catalyzed glucose fuel cell for powering medical implants: Reconstructed manufacturing protocol and analysis of performance., Journal of Power Sources, 182, 66, 10.1016/j.jpowsour.2008.03.049 · DOI
- S Kerzenmacher, 2010, Raney-platinum film electrodes for potentially implantable glucose fuel cells. Part 1: Nickel-free glucose oxidation anodes., Journal of Power Sources, 195, 6516, 10.1016/j.jpowsour.2010.04.039 · DOI
- S Kerzenmacher, 2010, Raney-platinum film electrodes for potentially implantable glucose fuel cells. Part 2: Glucose-tolerant oxygen reduction cathodes., Journal of Power Sources, 195, 6524, 10.1016/j.jpowsour.2010.04.049 · DOI
- GS Attard, 1997, Liquid-crystal templates for nanostructured metals., Angewandte Chemie International Edition, 36, 1315, 10.1002/anie.199713151 · DOI · Paper page
- GS Attard, 1997, Crystalline phases mesoporous platinum films from lyotropic liquid., Science, 278, 838, 10.1126/science.278.5339.838 · DOI · Paper page
- S Gold, 2004, Acid loaded porous silicon as a proton exchange membrane for micro-fuel cells., Journal of Power Sources, 135, 198, 10.1016/j.jpowsour.2004.03.084 · doi:10.1016/j.jpowsour.2004.03.084
- T Sharma, 2011, Mesoporous silica as a membrane for ultra-thin implantable direct glucose fuel cells., Lab on a Chip, 11, 2460, 10.1039/c1lc20119k · DOI
- B Ilic, 1999, Low temperature Nafion bonding of silicon wafers., Electrochemical and Solid-State Letters, 2, 86, 10.1149/1.1390743 · doi:10.1149/1.1390743
- YJ Lee, 2008, Fully packaged nonenzymatic glucose microsensors with nanoporous platinum electrodes for anti-fouling., IEEE Sensors Journal, 8, 1922, 10.1109/JSEN.2008.2006697 · doi:10.1109/jsen.2008.2006697
- S Prilutsky, 2010, Anodes for glucose fuel cells based on carbonized nanofibers with embedded carbon nanotubes., Electrochimica Acta, 55, 3694, 10.1016/j.electacta.2010.02.005 · doi:10.1016/j.electacta.2010.02.005
- G Wu, 2007, Carbon nanotube supported Pt electrodes for methanol oxidation: A comparison between multi- and single-walled carbon nanotubes., Journal of Power Sources, 174, 148, 10.1016/j.jpowsour.2007.08.024 · DOI · Paper page
- K Rabaey, 2003, A microbial fuel cell capable of converting clucose to electricity at high rate and efficiency., Biotechnology Letters, 25, 1531, 10.1023/A:1025484009367 · DOI · Paper page
- SK Chaudhuri, 2003, Electricity generation by direct oxidation of glucose in mediatorless microbial fuel cells., Nature Biotechnology, 21, 1229, 10.1038/nbt867 · DOI · Paper page
- KE Barrett, 2010, Ganong’s Review of Medical Physiology. Access Medicine.
- G Zaharchuk, 2005, Measurement of cerebrospinal uid oxygen partial pressure in humans using MRI., Magnetic Resonance in Medicine, 54, 113, 10.1002/mrm.20546 · doi:10.1002/mrm.20546
- K Lu, 2004, Cerebral autoregulation and gas exchange studied using a human cardiopulmonary model., American Journal of Physiology: Heart and Circulatory Physiology, 286, H584
- MW Denny, 1993, Air and Water: The Biology and Physics of Life’s Media., 10.1515/9780691213880 · DOI · Paper page
Cited by
Wireless power transfer to deep-tissue microimplants
Ho, J. S., Yeh, A. J., Neofytou, E., Kim, S., Tanabe, Y., Patlolla, B., Beygui, R. E., & Poon, A. S. Y. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1403002111 · Cited by 541
In Vivo Self-Powered Wireless Cardiac Monitoring via Implantable Triboelectric Nanogenerator
Zheng, Q., Zhang, H., Shi, B., Xue, X., Liu, Z., Jin, Y., Ma, Y., Zou, Y., Wang, X., An, Z., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b02693 · Cited by 449
Single Glucose Biofuel Cells Implanted in Rats Power Electronic Devices
Zebda, A., Cosnier, S., Alcaraz, J.-P., Holzinger, M., Le Goff, A., Gondran, C., Boucher, F., Giroud, F., Gorgy, K., Lamraoui, H., et al. (2013) · Scientific Reports · doi:10.1038/srep01516 · Cited by 370
Wireless and battery-free technologies for neuroengineering
Won, S. M., Cai, L., Gutruf, P., & Rogers, J. A. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00683-3 · Cited by 360
Implantable devices: issues and challenges
Bazaka, K., & Jacob, M. (2012) · Electronics · doi:10.3390/electronics2010001 · Cited by 358
Metadata
- Authors
- Rapoport, B. I., Kedzierski, J. T., & Sarpeshkar, R.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2012-06-12
- Volume
- 7
- Issue
- 6
- Pages
- e38436
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2116850839
- Cited by
- 242
- References
- 3
- FWCI
- 8.29
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Glucose Fuel Cell for Implantable Brain–Machine Interfaces. https://app.cochat.ai/papers/10.1371/journal.pone.0038436
- The paper
- Rapoport, B. I., Kedzierski, J. T., & Sarpeshkar, R. (2012). A Glucose Fuel Cell for Implantable Brain–Machine Interfaces. PLoS ONE. https://doi.org/10.1371/journal.pone.0038436
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.