A novel strategy for chromium speciation at ultra-trace level by microsample injection flame atomic absorption spectrophotometry
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Simple, robust and novel analytical procedures were developed for the speciation of chromium by carrier element co-precipitation (CECP) and dispersive liquid–liquid microextraction (DLLME) coupled with microsample injection system–flame atomic absorption spectrophotometry (MIS–FAAS). Ammonium pyrrolidine dithiocarbamate (APDC), carbon tetrachloride and ethanol were used as chelating agent, extraction solvent and disperser solvent, respectively for the determination of Cr(VI) by DLLME. For total chromium, Cr(III) was oxidized by Ce(SO4)2 in acidic media (0.07 mol L−1 H2SO4) and the resulting solution was co-precipitated with APDC. The concentration of Cr(III) was estimated by determining the difference between the concentration of total chromium and that of Cr(VI). The maximum recovery of Cr(VI) was obtained with DLLME at optimal conditions of pH 3.0 , 0.25% APDC, 100 μL CCl4, 1.00 mL of CH3CH2OH and 0.01 mg L−1 Cr(VI). Whereas, the optimal conditions for CECP were 40 mL initial volume of water samples, 0.25% APDC, 0.02% Ce(SO4)2 and 0.10 mg L−1 Cr(VI) concentration. The limits of detection and enrichment factor of DLLME and CECP were [0.037 and 2.13] and [400 and 100] μg L−1, respectively with 40 mL initial volumes. The relative standard deviations (RSD, n = 6) were <4%. The proposed method was successfully applied to the chromium speciation at ultra-trace levels in natural drinking water, industrial effluents waste water and an exchangeable fraction of garden soil from Denizli. Moreover, the proposed methods compared well with the literature reported method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chromium in Drinking Water: Sources, Metabolism, and Cancer Risks
Zhitkovich, A. (2011) · Chemical Research in Toxicology · doi:10.1021/tx200251t · Cited by 1,132
Extraction procedures for the determination of heavy metals in contaminated soil and sediment
Rauret, G. (1998) · Talanta · doi:10.1016/s0039-9140(97)00406-2 · Cited by 511
Automated on-line dispersive liquid–liquid microextraction based on a sequential injection system
Andruch, V., Acebal, C. C., Škrlíková, J., Sklenářová, H., Solich, P., Balogh, I. S., Billes, F., & Kocúrová, L. (2012) · Microchemical Journal · doi:10.1016/j.microc.2011.09.006 · Cited by 115
Cited by
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
“037 mg L¡1 (1352) Cr, Co, Ni, Pb Water DLLME-SFO GFAAS 0.”
Seidi, S., Alavi, L., & Jabbari, A. (2019) · Biological Trace Element Research · doi:10.1007/s12011-018-1438-3 · Cited by 20
Seval, K., & Akdoğan, A. (2022) · International Journal of Environmental Analytical Chemistry · doi:10.1080/03067319.2020.1849656 · Cited by 8
Self-citation
Metadata
- Authors
- Baig, J. A., Hol, A., Akdogan, A., Kartal, A. A., Divrikli, U., Kazi, T. G., & Elci, L.
- Venue
- Journal of Analytical Atomic Spectrometry
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 27
- Issue
- 9
- Pages
- 1509
- ISSN
- 0267-9477 (ISSN-L)
- 1364-5544
- OpenAlex
- W2076884714
- Cited by
- 47
- References
- 3
- FWCI
- 6.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A novel strategy for chromium speciation at ultra-trace level by microsample injection flame atomic absorption spectrophotometry. https://app.cochat.ai/papers/10.1039/c2ja30107e
- The paper
- Baig, J. A., Hol, A., Akdogan, A., Kartal, A. A., Divrikli, U., Kazi, T. G., & Elci, L. (2012). A novel strategy for chromium speciation at ultra-trace level by microsample injection flame atomic absorption spectrophotometry. Journal of Analytical Atomic Spectrometry. https://doi.org/10.1039/c2ja30107e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.