The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Sorting cells by size, shape and deformability
Open accessAbstract
While size has been widely used as a parameter in cellular separations, in this communication we show how shape and deformability, a mainly untapped source of specificity in preparative and analytical microfluidic devices can be measured and used to separate cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Continuous Particle Separation Through Deterministic Lateral Displacement
Huang, L. R., Cox, E. C., Austin, R. H., & Sturm, J. C. (2004) · Science · doi:10.1126/science.1094567 · Cited by 1,634
Biological Membranes as Bilayer Couples. A Molecular Mechanism of Drug-Erythrocyte Interactions
Sheetz, M. P., & Singer, S. J. (1974) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.71.11.4457 · Cited by 1,385
The Optical Stretcher: A Novel Laser Tool to Micromanipulate Cells
Guck, J., Ananthakrishnan, R., Mahmood, H., Moon, T. J., Cunningham, C. C., & Käs, J. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)75740-2 · Cited by 977
Deterministic hydrodynamics: Taking blood apart
Davis, J. A., Inglis, D. W., Morton, K. J., Lawrence, D. A., Huang, L. R., Chou, S. Y., Sturm, J. C., & Austin, R. H. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0605967103 · Cited by 622
Deformability-based cell classification and enrichment using inertial microfluidics
Hur, S. C., Henderson-MacLennan, N. K., McCabe, E. R. B., & Di Carlo, D. (2011) · Lab on a Chip · doi:10.1039/c0lc00595a · Cited by 576
Lim H. W., G., Wortis, M., & Mukhopadhyay, R. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.202617299 · Cited by 520
Hou, H. W., Bhagat, A. A. S., Lin Chong, A. G., Mao, P., Wei Tan, K. S., Han, J., & Lim, C. T. (2010) · Lab on a Chip · doi:10.1039/c003873c · Cited by 300
The clinical importance of erythrocyte deformability, a hemorrheological parameter
Mokken, F. C., Kedaria, M., Henny, C. P., Hardeman, M. R., & Gelb, A. W. (1992) · Annals of Hematology · doi:10.1007/bf01697397 · Cited by 173
Cell Membrane: The Red Blood Cell as a Model
Yawata, Y. (2003) · Cited by 84
Sugaya, S., Yamada, M., & Seki, M. (2011) · Biomicrofluidics · doi:10.1063/1.3580757 · Cited by 68
Microfluidic Separation of Blood Components through Deterministic Lateral Displacement
Davis, J. A. (2008) · Cited by 62
Cited by
Wyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Particle separation and sorting in microfluidic devices: a review
Sajeesh, P., & Sen, A. K. (2014) · Microfluidics and Nanofluidics · doi:10.1007/s10404-013-1291-9 · Cited by 767
Real-time deformability cytometry: on-the-fly cell mechanical phenotyping
Otto, O., Rosendahl, P., Mietke, A., Golfier, S., Herold, C., Klaue, D., Girardo, S., Pagliara, S., Ekpenyong, A., Jacobi, A., et al. (2015) · Nature Methods · doi:10.1038/nmeth.3281 · Cited by 736
Rare cell isolation and analysis in microfluidics
Chen, Y., Li, P., Huang, P.-H., Xie, Y., Mai, J. D., Wang, L., Nguyen, N.-T., & Huang, T. J. (2014) · Lab on a Chip · doi:10.1039/c3lc90136j · Cited by 307
Dalili, A., Samiei, E., & Hoorfar, M. (2019) · The Analyst · doi:10.1039/c8an01061g · Cited by 280
Metadata
- Authors
- Beech, J. P., Holm, S. H., Adolfsson, K., & Tegenfeldt, J. O.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 6
- Pages
- 1048
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2107665723
- Cited by
- 277
- References
- 11
- FWCI
- 15.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.