Electrode calibration with a microfluidic flow cell for fast-scan cyclic voltammetry
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Fast-scan cyclic voltammetry (FSCV) is a common analytical electrochemistry tool used to measure chemical species. It has recently been adapted for measurement of neurotransmitters such as dopamine in awake and behaving animals (in vivo). Electrode calibration is an essential step in FSCV to relate observed current to concentration of a chemical species. However, existing methods require multiple components, which reduce the ease of calibrations. To this end, a microfluidic flow cell (μFC) was developed as a simple device to switch between buffer and buffer with a known concentration of the analyte of interest--in this case dopamine--in a microfluidic Y-channel. The ability to quickly switch solutions yielded electrode calibrations with faster rise times and that were more stable at peak current values. The μFC reduced the number of external electrical components and produced linear calibrations over a range of concentrations. To demonstrate this, an electrode calibrated with the μFC was used in FSCV recordings from a rat during the delivery of food reward--a stimulus that reliably evokes a brief increase in current due to the oxidation of dopamine. Using the linear calibration, dopamine concentrations were determined from the current responses evoked during the behavioral task. The μFC is able to easily and quickly calibrate FSCV electrode responses to chemical species for both in vitro and in vivo experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Subsecond dopamine release promotes cocaine seeking
Phillips, P. E. M., Stuber, G. D., Heien, M. L. A. V., Wightman, R. M., & Carelli, R. M. (2003) · Nature · doi:10.1038/nature01476 · Cited by 1,113
Dopamine operates as a subsecond modulator of food seeking
Roitman, M. F., Stuber, G. D., Phillips, P. E. M., Wightman, R. M., & Carelli, R. M. (2004) · The Journal of Neuroscience · doi:10.1523/jneurosci.3823-03.2004 · Cited by 718
Self-citationAssociative learning mediates dynamic shifts in dopamine signaling in the nucleus accumbens
Day, J. J., Roitman, M. F., Wightman, R. M., & Carelli, R. M. (2007) · Nature Neuroscience · doi:10.1038/nn1923 · Cited by 710
Self-citationDissociation of dopamine release in the nucleus accumbens from intracranial self-stimulation
Garris, P. A., Kilpatrick, M., Bunin, M. A., Michael, D., Walker, Q. D., & Wightman, R. M. (1999) · Nature · doi:10.1038/18019 · Cited by 327
Cited by
Badrinarayan, A., Wescott, S. A., Vander Weele, C. M., Saunders, B. T., Couturier, B. E., Maren, S., & Aragona, B. J. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.3557-12.2012 · Cited by 225
“, 2009), with the additional use of a novel flow cell, which was used for in vitro calibrations (Sinkala et al., 2012).”
BackgroundMethodA descending dopamine pathway conserved from basal vertebrates to mammals
Ryczko, D., Cone, J. J., Alpert, M. H., Goetz, L., Auclair, F., Dubé, C., Parent, M., Roitman, M. F., Alford, S., & Dubuc, R. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1600684113 · Cited by 101
“6 V) as in lampreys (22) and rats (81, 82).”
Self-citationDopamine and opioid systems interact within the nucleus accumbens to maintain monogamous pair bonds
Resendez, S. L., Keyes, P. C., Day, J. J., Hambro, C., Austin, C. J., Maina, F. K., Eidson, L. N., Porter-Stransky, K. A., Nevárez, N., McLean, J. W., et al. (2016) · eLife · doi:10.7554/elife.15325 · Cited by 88
“The peak currents for DA were converted to concentration by calibrating each electrode to a known concentration of DA (3 mM) (Sinkala et al., 2012; Vander Weele et al., 2014).”
Metadata
- Authors
- Sinkala, E., McCutcheon, J. E., Schuck, M. J., Schmidt, E., Roitman, M. F., & Eddington, D. T.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 13
- Pages
- 2403
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2158997247
- Cited by
- 49
- References
- 4
- FWCI
- 3.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrode calibration with a microfluidic flow cell for fast-scan cyclic voltammetry. https://app.cochat.ai/papers/10.1039/c2lc40168a
- The paper
- Sinkala, E., McCutcheon, J. E., Schuck, M. J., Schmidt, E., Roitman, M. F., & Eddington, D. T. (2012). Electrode calibration with a microfluidic flow cell for fast-scan cyclic voltammetry. Lab on a Chip. https://doi.org/10.1039/c2lc40168a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.