A novel microfluidic platform for high-resolution imaging of a three-dimensional cell culture under a controlled hypoxic environment
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Low oxygen tensions experienced in various pathological and physiological conditions are a major stimulus for angiogenesis. Hypoxic conditions play a critical role in regulating cellular behaviour including migration, proliferation and differentiation. This study introduces the use of a microfluidic device that allows for the control of oxygen tension for the study of different three-dimensional (3D) cell cultures for various applications. The device has a central 3D gel region acting as an external cellular matrix, flanked by media channels. On each side, there is a peripheral gas channel through which suitable gas mixtures are supplied to establish a uniform oxygen tension or gradient within the device. The effects of various parameters, such as gas and media flow rates, device thickness, and diffusion coefficients of oxygen were examined using numerical simulations to determine the characteristics of the microfluidic device. A polycarbonate (PC) film with a low oxygen diffusion coefficient was embedded in the device in proximity above the channels to prevent oxygen diffusion from the incubator environment into the polydimethylsiloxane (PDMS) device. The oxygen tension in the device was then validated experimentally using a ruthenium-coated (Ru-coated) oxygen-sensing glass cover slip which confirmed the establishment of low uniform oxygen tensions (<3%) or an oxygen gradient across the gel region. To demonstrate the utility of the microfluidic device for cellular experiments under hypoxic conditions, migratory studies of MDA-MB-231 human breast cancer cells were performed. The microfluidic device allowed for imaging cellular migration with high-resolution, exhibiting an enhanced migration in hypoxia in comparison to normoxia. This microfluidic device presents itself as a promising platform for the investigation of cellular behaviour in a 3D gel scaffold under varying hypoxic conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tumor Hypoxia: Definitions and Current Clinical, Biologic, and Molecular Aspects
Hockel, M., & Vaupel, P. (2001) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/93.4.266 · Cited by 2,662
Three-dimensional microfluidic model for tumor cell intravasation and endothelial barrier function
Zervantonakis, I. K., Hughes-Alford, S. K., Charest, J. L., Condeelis, J. S., Gertler, F. B., & Kamm, R. D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1210182109 · Cited by 872
Self-citationInterstitial flow influences direction of tumor cell migration through competing mechanisms
Polacheck, W. J., Charest, J. L., & Kamm, R. D. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1103581108 · Cited by 509
Self-citationThe hypoxic tumour microenvironment and metastatic progression
Subarsky, P., & Hill, R. P. (2003) · Clinical & Experimental Metastasis · doi:10.1023/a:1022939318102 · Cited by 327
Migration dynamics of breast cancer cells in a tunable 3D interstitial flow chamber
Haessler, U., Teo, J. C. M., Foretay, D., Renaud, P., & Swartz, M. A. (2012) · Integrative Biology · doi:10.1039/c1ib00128k · Cited by 176
Cited by
The hypoxic tumor microenvironment: A driving force for breast cancer progression
Semenza, G. L. (2016) · Biochimica et Biophysica Acta (BBA) - Molecular Cell Research · doi:10.1016/j.bbamcr.2015.05.036 · Cited by 535
“More recent studies have utilized microfluidic approaches to image cell motility in three dimensional cell culture [72].”
BackgroundBiological detection by optical oxygen sensing
Papkovsky, D. B., & Dmitriev, R. I. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60131e · Cited by 444
Microfluidic platforms for mechanobiology
Polacheck, W. J., Li, R., Uzel, S. G. M., & Kamm, R. D. (2013) · Lab on a Chip · doi:10.1039/c3lc41393d · Cited by 272
Tumour-on-a-chip: microfluidic models of tumour morphology, growth and microenvironment
Tsai, H.-F., Trubelja, A., Shen, A. Q., & Bao, G. (2017) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0137 · Cited by 214
Oxygen control with microfluidics
Brennan, M. D., Rexius-Hall, M. L., Elgass, L. J., & Eddington, D. T. (2014) · Lab Chip · doi:10.1039/c4lc00853g · Cited by 188
3D scaffolds in breast cancer research
Rijal, G., & Li, W. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2015.12.016 · Cited by 169
Chang, C.-W., Cheng, Y.-J., Tu, M., Chen, Y.-H., Peng, C.-C., Liao, W.-H., & Tung, Y.-C. (2014) · Lab Chip · doi:10.1039/c4lc00732h · Cited by 154
Development and characterization of a microfluidic model of the tumour microenvironment
Ayuso, J. M., Virumbrales-Muñoz, M., Lacueva, A., Lanuza, P. M., Checa-Chavarria, E., Botella, P., Fernández, E., Doblare, M., Allison, S. J., Phillips, R. M., et al. (2016) · Scientific Reports · doi:10.1038/srep36086 · Cited by 134
Metastasis in context: modeling the tumor microenvironment with cancer-on-a-chip approaches
Sleeboom, J. J. F., Eslami Amirabadi, H., Nair, P., Sahlgren, C. M., & den Toonder, J. M. J. (2018) · Disease Models & Mechanisms · doi:10.1242/dmm.033100 · Cited by 122
“Based on this method, a gradient across a 3D hydrogel (Oppegard and Eddington, 2013) and a gradient across a compartmentalized chip with a collagen ECM and a vessel-mimicking channel (Acosta et al., 2014) Funamoto et al., 2012), and thus enabled more accurate quantification of the oxygen response.”
Methods to study the tumor microenvironment under controlled oxygen conditions
Byrne, M. B., Leslie, M. T., Gaskins, H. R., & Kenis, P. J. A. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.09.006 · Cited by 104
Lin, X., Chen, Q., Liu, W., Zhang, J., Wang, S., Lin, Z., & Lin, J.-M. (2015) · Scientific Reports · doi:10.1038/srep09643 · Cited by 67
Rivera, K. R., Yokus, M. A., Erb, P. D., Pozdin, V. A., & Daniele, M. (2019) · The Analyst · doi:10.1039/c8an02201a · Cited by 57
Koens, R., Tabata, Y., Serrano, J. C., Aratake, S., Yoshino, D., Kamm, R. D., & Funamoto, K. (2020) · APL Bioengineering · doi:10.1063/1.5127069 · Cited by 53
Self-citationHan, B., Qu, C., Park, K., Konieczny, S. F., & Korc, M. (2016) · Cancer Letters · doi:10.1016/j.canlet.2015.12.003 · Cited by 53
“In addition, a microfluidic platform has been proposed to mimic hypoxia [144].”
Berger Fridman, I., Ugolini, G. S., VanDelinder, V., Cohen, S., & Konry, T. (2021) · Biofabrication · doi:10.1088/1758-5090/abdb88 · Cited by 46
“Ru complex has been previously used in hypoxia microfluidic models successfully, in water solu-tion or Ru-coated cover slips [34, 48].”
Wang, Z., Liu, Z., Li, L., & Liang, Q. (2015) · Microfluidics and Nanofluidics · doi:10.1007/s10404-015-1637-6 · Cited by 28
Sun, W., Chen, Y., Wang, Y., Luo, P., Zhang, M., Zhang, H., & Hu, P. (2018) · The Analyst · doi:10.1039/c8an01216d · Cited by 25
Quantitative design strategies for fine control of oxygen in microfluidic systems
Shirure, V. S., Lam, S. F., Shergill, B., Chu, Y. E., Ng, N. R., & George, S. C. (2020) · Lab on a Chip · doi:10.1039/d0lc00350f · Cited by 21
Metadata
- Authors
- Funamoto, K., Zervantonakis, I. K., Liu, Y., Ochs, C. J., Kim, C., & Kamm, R. D.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 22
- Pages
- 4855
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1513982285
- Cited by
- 151
- References
- 5
- FWCI
- 5.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.